Impacts of Room Temperature on the Performance of a Portable Propane Air Conditioner

被引:2
|
作者
Sharifian, Ahmad [1 ]
Siang, Jeri Tangalajuk [2 ]
机构
[1] Univ Southern Queensland, CESRC, Toowoomba, Qld, Australia
[2] Univ Southern Queensland, Fac Hlth Engn & Sci, Sch Mech & Elect Engn, Toowoomba, Qld, Australia
关键词
Room temperature; performance; portable;
D O I
10.1142/S2010132515500157
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of a portable propane air conditioner system, in which the temperatures of the air passing over the condenser and evaporator are equal, has been experimentally investigated under different room temperatures and refrigerant charge levels. The research has been carried out in a range of room temperatures from 20 degrees C to 35 degrees C and in undercharge, standard charge and overcharge conditions. The results show that, at higher room temperatures, the refrigerant temperature in all parts of the system, the density of the refrigerant at the inlet and outlet of the condenser, mass of the refrigerant in the compressor, the mass flow rate of the refrigerant and the cooling capacity of the system in either the undercharge or full charge condition, the specific cooling capacity of the undercharge system, the useful work of the compressor, and the maximum pressure of the refrigerant increase. The increase in room temperature decreases the density of the refrigerant at the inlet and outlet of the capillary tube, the mass of the refrigerant in the capillary tube, the refrigerant subcooling at the inlet of the capillary tube, the maximum velocity of the refrigerant and the coefficient of performance. In addition, the increase in room temperature at overcharge condition causes an increase in the mass flow rate, cooling capacity and specific cooling capacity to a maximum value followed by their decrease. The most important difference between a portable air conditioner and a nonportable system is the increase in cooling capacity with an increase in room temperature in full charge condition.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] ROOM AIR CONDITIONER DESIGN PARAMETERS - PERFORMANCE
    METCALFE, FS
    [J]. ASHRAE JOURNAL, 1970, 12 (01): : 43 - &
  • [2] ROOM AIR CONDITIONER
    不详
    [J]. METAL PROGRESS, 1971, 99 (02): : 80 - &
  • [3] AIR CONDITIONER IN OPERATING ROOM
    WALTER, CW
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 160 (02): : 152 - 152
  • [4] AIR CONDITIONER IN OPERATING ROOM
    不详
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1955, 158 (15): : 1405 - 1405
  • [5] SIMAIR + ROOM AIR CONDITIONER
    不详
    [J]. DOMUS, 1975, (552): : 39 - 39
  • [6] Performance evaluation of a window room air conditioner with microchannel condensers
    Kim, MH
    Bullard, CW
    [J]. JOURNAL OF ENERGY RESOURCES TECHNOLOGY-TRANSACTIONS OF THE ASME, 2002, 124 (01): : 47 - 55
  • [7] Flow impact of an air conditioner to portable air cleaning
    Zhang, Tengfei
    Wang, Shugang
    Sun, Gangsen
    Xu, Linxiao
    Takaoka, Daizo
    [J]. BUILDING AND ENVIRONMENT, 2010, 45 (09) : 2047 - 2056
  • [8] Optimization temperature in the room using air conditioner with finite element methods
    Tulus, Tulus
    Simbolon, Lamtiur
    Sawaluddin, Sawaluddin
    Marpaung, T. J.
    [J]. 3RD ANNUAL APPLIED SCIENCE AND ENGINEERING CONFERENCE (AASEC 2018), 2018, 197
  • [9] ROOM AIR CONDITIONER STORY . INTRODUCTION
    KOLB, PE
    [J]. ASHRAE JOURNAL, 1970, 12 (01): : 43 - &
  • [10] Air conditioner 'in a patch' provides portable cooling
    不详
    [J]. NATURE, 2019, 569 (7758) : 603 - 603