Optimization temperature in the room using air conditioner with finite element methods

被引:0
|
作者
Tulus, Tulus [1 ]
Simbolon, Lamtiur [1 ]
Sawaluddin, Sawaluddin [1 ]
Marpaung, T. J. [1 ]
机构
[1] Univ Sumatera Utara, Dept Math, Padang Bulan 20155, Medan, Indonesia
关键词
D O I
10.1051/matecconf/201819701009
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Room temperature is one of the problems in everyday life that is often discussed. One of the tools in regulating the temperature is Air Conditioner (AC). As is known, that the AC work process in cooling the room is the process of heat transfer. This study aims to find out how the AC works in regulating the temperature in a room. In the process, this research is accomplished by implementing finite element method on the energy transfer equation. Where the energy transfer equation is the partial differential used for heat transfer. In the finite element method, the flow field is broken down into a set of small fluid elements (discrete domains). In the solution, use it in three-dimensional space, then select the linear interpolation function for the 3D element, and derive the matrix and vector elements by the Galerkin method to obtain global equations. Results from computer-assisted studies show the temperature distribution in the room of COMSOL Multiphysic 5.0. Simulation results with COMSOL show that there is a correlation between AC location and solar radiation indoors against indoor temperature.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] Optimization for Pipeline System of Air-conditioner Based on Finite Element Simulation
    LiPP, Suyang
    Guo, JunPP
    Zhang, XiaoweiPP
    Tang, Wenyan
    [J]. FRONTIERS OF MANUFACTURING AND DESIGN SCIENCE II, PTS 1-6, 2012, 121-126 : 2151 - +
  • [2] Temperature field measurement around the room air conditioner using the LIF technique
    An, KH
    Lee, IS
    [J]. JSME INTERNATIONAL JOURNAL SERIES B-FLUIDS AND THERMAL ENGINEERING, 2000, 43 (04) : 622 - 627
  • [3] ROOM AIR CONDITIONER
    不详
    [J]. METAL PROGRESS, 1971, 99 (02): : 80 - &
  • [4] Impacts of Room Temperature on the Performance of a Portable Propane Air Conditioner
    Sharifian, Ahmad
    Siang, Jeri Tangalajuk
    [J]. INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2015, 23 (02)
  • [5] AIR CONDITIONER IN OPERATING ROOM
    WALTER, CW
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1956, 160 (02): : 152 - 152
  • [6] AIR CONDITIONER IN OPERATING ROOM
    不详
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1955, 158 (15): : 1405 - 1405
  • [7] SIMAIR + ROOM AIR CONDITIONER
    不详
    [J]. DOMUS, 1975, (552): : 39 - 39
  • [8] Finite element analysis of dynamic stress of the outdoor unit of air conditioner
    Yang, Rong
    Li, Shiyun
    Zhou, Shaoping
    Guo, Jun
    Zhang, Lanzhu
    Hui, Hu
    [J]. EVALUATION, INSPECTION AND MONITORING OF STRUCTURAL INTEGRITY, 2008, : 153 - 157
  • [9] A Review of Finite Element Methods for Room Acoustics
    Prinn, Albert G.
    [J]. ACOUSTICS, 2023, 5 (02): : 367 - 395
  • [10] Rack Temperature Prediction Model Using Machine Learning after Stopping Computer Room Air Conditioner in Server Room
    Sasakura, Kosuke
    Aoki, Takeshi
    Komatsu, Masayoshi
    Watanabe, Takeshi
    [J]. ENERGIES, 2020, 13 (17)