ORIGINS OF SPURIOUS PEAKS OF TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS OF SI WAFERS EXCITED BY MONOCHROMATIC X-RAY-BEAM W-L-BETA

被引:9
|
作者
YAKUSHIJI, K
OHKAWA, S
YOSHINAGA, A
HARADA, J
机构
[1] SHOWA DENKO CO LTD,CHICHIBU WORKS,CHICHIBU,SAITAMA 36918,JAPAN
[2] NAGOYA UNIV,DEPT APPL PHYS,CHIKUSA KU,NAGOYA 46401,JAPAN
来源
JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS | 1994年 / 33卷 / 02期
关键词
TOTAL REFLECTION X-RAY FLUORESCENCE; SILICON WAFER; SURFACE DIFFRACTION; BRAGG REFLECTION; X-RAY ASYMMETRIC REFLECTION; TRACE ANALYSIS; SURFACE ANALYSIS; RELIABILITY OF ANALYSIS; BERYLLIUM; SOLID STATE DETECTOR;
D O I
10.1143/JJAP.33.1130
中图分类号
O59 [应用物理学];
学科分类号
摘要
Spurious peaks such as Fe-Kalpha or Ni-Kalpha radiations are observed in the analysis of trace metallic impurities on a Si wafer by monochromatic total reflection X-ray fluorescence. These peaks seriously influence the accuracy in the quantitative analysis of the trace impurities. Intensities of these peaks are shown to depend on the intensity of the elastically scattered primary beam (W-Lbeta) whose intensity varies with the incident azimuth. It is found that impurity radiations are included in the primary X-ray beam, and contaminations in the Be window of the X-ray detector are also a source of spurious peaks. The impurities deposited on the Be window, in and/or on the Si(Li) crystal of the detector and the casing material of the X-ray detector can also contribute to these spurious peaks.
引用
收藏
页码:1130 / 1135
页数:6
相关论文
共 50 条
  • [31] ENHANCEMENT OF TOTAL-REFLECTION X-RAY-FLUORESCENCE SPECTROSCOPY WITH ELECTROCHEMICAL DEPOSITION
    FAN, QA
    GOHSHI, Y
    APPLIED SPECTROSCOPY, 1993, 47 (11) : 1742 - 1746
  • [32] MICROANALYSIS OF SOLID SAMPLES BY TOTAL-REFLECTION X-RAY-FLUORESCENCE SPECTROMETRY
    VONBOHLEN, A
    ELLER, R
    KLOCKENKAMPER, R
    TOLG, G
    ANALYTICAL CHEMISTRY, 1987, 59 (21) : 2551 - 2555
  • [33] DEPTH PROFILING IN SURFACES USING TOTAL-REFLECTION X-RAY-FLUORESCENCE
    SCHWENKE, H
    KNOTH, J
    ANALYTICAL SCIENCES, 1995, 11 (03) : 533 - 537
  • [34] CALIBRATION PROCEDURE FOR QUANTITATIVE SURFACE-ANALYSIS BY TOTAL-REFLECTION X-RAY-FLUORESCENCE
    TORCHEUX, L
    DEGRAEVE, B
    MAYEUX, A
    DELAMAR, M
    SURFACE AND INTERFACE ANALYSIS, 1994, 21 (03) : 192 - 198
  • [35] DETERMINATION OF METALS IN COOLING LUBRICANTS BY USE OF TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS
    HAHN, JU
    JASCHKE, M
    STAUB REINHALTUNG DER LUFT, 1993, 53 (03): : 109 - 113
  • [36] COLLECTION OF AIRBORNE PARTICULATE MATTER FOR A SUBSEQUENT ANALYSIS BY TOTAL-REFLECTION X-RAY-FLUORESCENCE
    KLOCKENKAMPER, R
    BAYER, H
    VONBOHLEN, A
    SCHMELING, M
    KLOCKOW, D
    ANALYTICAL SCIENCES, 1995, 11 (03) : 495 - 498
  • [37] A NEW SPECTROMETER FOR TOTAL-REFLECTION X-RAY-FLUORESCENCE ANALYSIS OF LIGHT-ELEMENTS
    STRELI, C
    WOBRAUSCHEK, P
    UNFRIED, E
    AIGINGER, H
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1993, 334 (2-3): : 425 - 429
  • [38] LIGHT-ELEMENT ANALYSIS WITH A NEW SPECTROMETER FOR TOTAL-REFLECTION X-RAY-FLUORESCENCE
    STRELI, C
    AIGINGER, H
    WOBRAUSCHEK, P
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1993, 48 (02) : 163 - 170
  • [39] DETERMINATION OF TRACE-ELEMENTS IN RAINWATER BY TOTAL-REFLECTION X-RAY-FLUORESCENCE
    STOSSEL, RP
    PRANGE, A
    ANALYTICAL CHEMISTRY, 1985, 57 (14) : 2880 - 2885
  • [40] Surface analysis by total-reflection X-ray fluorescence
    Sanchez, HJ
    Perez, CA
    Perez, RD
    Rubio, M
    RADIATION PHYSICS AND CHEMISTRY, 1996, 48 (03): : 325 - 331