LEAD DETERMINATION IN WINE BY POTENTIOMETRIC STRIPPING ANALYSIS

被引:30
|
作者
MARIN, C
OSTAPCZUK, P
机构
[1] FORSCHUNGSZENTRUM JULICH, RES CTR JULICH, INST APPL PHYS CHEM, POB 1913, W-5170 JULICH 1, GERMANY
[2] UNIV EXTREMADURA, DEPT ANALYT CHEM & ELECTROCHEM, E-06071 BADAJOZ, SPAIN
来源
关键词
D O I
10.1007/BF00321958
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Computerized potentiometric stripping analysis (PSA) was used for lead determination in wine samples. In this method sample preparation before determination is limited to dilution with an appropriate supporting electrolyte (0.5 mol/l HCl and 40 mg/l Hg2+). Due to the very high sensitivity, the time needed for one determination can be reduced to 2 min. The method was tested by lead determination in different wines, different concentration ranges and in one European interlaboratory comparison organized by BCR. Using PSA it is possible to simultaneously determine cadmium, lead and copper in wine. For other elements such as Bi, Tl, Hg, Sn, As, Zn the determination procedures are under development. The PSA equipment is available on the market, small in size, relatively cheap and it does not require any special installation such as gas or cooling water.
引用
收藏
页码:881 / 886
页数:6
相关论文
共 50 条