A LOW-Z PET DETECTOR

被引:7
|
作者
BURNHAM, CA
KAUFMAN, DE
CHESLER, DA
STEARNS, CW
CORREIA, JA
BROWNELL, GL
机构
[1] Physics Research Laboratory, Massachusetts General Hospital, Boston, MA
关键词
D O I
10.1109/23.106723
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to examine the potential of low-Z detector materials for PET, a small field imaging system using plastic detectors has been designed. In this system the site of a photon interaction in the detector is located using light produced by the first Compton electron. This is in contrast to high-Z detectors where multiple interactions occur. The calculated performance of the detector and supporting measurements are presented. Copyright © 1990 by The Institute of Electrical and Electronics Engineers, Inc.
引用
收藏
页码:832 / 834
页数:3
相关论文
共 50 条
  • [1] Low-z power conditioners
    Chilton's I&CS (Instruments & Control Systems), 1991, 64 (04):
  • [2] SPUTTERING OF LOW-Z MATERIALS
    ROTH, J
    ECKSTEIN, W
    GAUTHIER, E
    LASZLO, J
    JOURNAL OF NUCLEAR MATERIALS, 1991, 179 : 34 - 36
  • [3] Methods for simulating TOF-PET in TOPAS using a low-Z medium
    Domurat-Sousa, Kepler
    Poe, Cameron
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057
  • [4] Low-Z collimator for SuperKEKB
    Terui, S.
    Ishibashi, T.
    Abe, T.
    Funakoshi, Y.
    Nakayama, H.
    Ohmi, K.
    Zhou, D.
    Natochii, A.
    Yoshifuji, N.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1047
  • [5] AN ULTRASOFT X-RAY-FLUORESCENCE DETECTOR FOR EXAFS MEASUREMENTS ON LOW-Z ELEMENTS
    MAEYAMA, S
    OSHIMA, M
    SHOJI, T
    YAMAMOTO, H
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1991, 62 (01): : 58 - 61
  • [6] LOW-Z IMPURITY TRANSPORT IN TOKAMAKS
    HAWRYLUK, RJ
    SUCKEWER, S
    HIRSHMAN, SP
    NUCLEAR FUSION, 1979, 19 (05) : 607 - 632
  • [7] Lithium abundances in low-Z stars
    Cayrel, R
    SPACE SCIENCE REVIEWS, 1998, 84 (1-2) : 145 - 154
  • [8] Low-dose high-resolution TOF-PET using ionization-activated multi-state low-Z detector media
    Shida, J. F.
    Spieglan, E.
    Adams, B. W.
    Angelico, E.
    Domurat-Sousa, K.
    Elagin, A.
    Frisch, H. J.
    La Riviere, P.
    Squires, A. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 1017
  • [9] X-RAY-FLUORESCENCE DETECTION OF LOW-Z ELEMENTS USING A MICROCHANNEL PLATE DETECTOR
    ROSENBERG, RA
    SIMONS, JK
    FRIGO, SP
    TAN, K
    CHEN, JM
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (04): : 2193 - 2194
  • [10] LOW-Z IMPURITIES IN PLT TOKAMAK
    HINNOV, E
    SUCKEWER, S
    BOL, K
    HAWRYLUK, RJ
    HOSEA, J
    MESERVEY, E
    PLASMA PHYSICS AND CONTROLLED FUSION, 1978, 20 (08) : 723 - 734