MEASUREMENT OF OXYGEN PARTIAL-PRESSURE USING A MINIATURE OXYGEN PUMP-GAUGE OPERATED IN THE POTENTIOMETRIC MODE

被引:6
|
作者
BENAMMAR, M [1 ]
MASKELL, WC [1 ]
机构
[1] MIDDLESEX POLYTECH, CTR ENERGY TECHNOL, BOUNDS GREEN RD, LONDON N11 2NQ, ENGLAND
关键词
D O I
10.1016/0167-2738(92)90367-X
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
An instrument for oxygen partial pressure measurement constructed around a sealed zirconia oxygen pump-gauge sensor Operated in the ac mode is described. By appropriate signal processing of the gauge output the oxygen partial pressure inside the sensor, P0, was determined and maintained constant via a feedback loop. The measurement of the oxygen partial pressure in the sample gas, P1, was made potentiometrically relative to this controlled internal reference.
引用
收藏
页码:75 / 79
页数:5
相关论文
共 50 条
  • [41] EFFECT OF OXYGEN PARTIAL-PRESSURE ON NITRIDATION OF SILICON
    MITOMO, M
    JOURNAL OF THE AMERICAN CERAMIC SOCIETY, 1975, 58 (11-1) : 527 - 527
  • [42] EFFECTIVE OXYGEN PARTIAL-PRESSURE DURING HIP
    WATANABE, A
    HANEDA, H
    HISHITA, S
    MORIYOSHI, Y
    SHIRASAKI, S
    YAMAMURA, H
    NIPPON SERAMIKKUSU KYOKAI GAKUJUTSU RONBUNSHI-JOURNAL OF THE CERAMIC SOCIETY OF JAPAN, 1990, 98 (06): : 529 - 532
  • [43] Preparation and electrochemical characteristics of a planar zirconia oxygen pump-gauge with silver electrodes
    Sato, M
    Kaneko, H
    JOURNAL OF THE JAPAN INSTITUTE OF METALS, 2001, 65 (09) : 767 - 770
  • [44] CLINICAL WORTH OF TRANS-CUTANEOUS MEASUREMENT OF OXYGEN PARTIAL-PRESSURE IN ADULTS
    GOERG, R
    LINSENMEYER, HM
    EMSLANDER, HP
    ATEMWEGS-UND LUNGENKRANKHEITEN, 1987, 13 (05) : 190 - 190
  • [45] DIRECT MEASUREMENT OF OXYGEN PARTIAL-PRESSURE IN BLAST-FURNACE RACE WAY
    SHIBATA, K
    KUSHIMA, K
    YOSHIDA, H
    HAMADA, M
    MATSUOKA, M
    KOSAKA, H
    TRANSACTIONS OF THE IRON AND STEEL INSTITUTE OF JAPAN, 1986, 26 (04) : B161 - B161
  • [46] OXYMETER, A NEW DEVICE FOR CONTINUOUS TRANSCUTANEOUS MEASUREMENT OF ARTERIAL OXYGEN PARTIAL-PRESSURE
    REINEKE, H
    FIESEL, G
    FRANKENBERGER, H
    AHNEFELD, FW
    ANAESTHESIST, 1977, 26 (07): : 361 - 368
  • [47] AMPEROMETRIC-TITRATION OF NITRIC MONOXIDE IN INERT-GASES USING A ZIRCONIA OXYGEN PUMP-GAUGE
    KANEKO, H
    MIKAMI, N
    TAIMATSU, H
    DENKI KAGAKU, 1991, 59 (06): : 478 - 482
  • [48] CONTROL AND MEASUREMENT OF VERY LOW OXYGEN PARTIAL-PRESSURE WITH STABILIZED ZIRCONIA CELLS
    NAITO, K
    TSUJI, T
    WATANABE, S
    SAKAI, H
    SOLID STATE IONICS, 1981, 3-4 (AUG) : 635 - 639
  • [49] MEASUREMENT OF THE OXYGEN PARTIAL-PRESSURE ON THE BRAIN SURFACE IN CASES OF BRAIN-TUMORS
    SCHULTHEISS, R
    LENIGERFOLLERT, E
    WULLENWEBER, R
    ACTA NEUROCHIRURGICA, 1983, 68 (1-2) : 158 - 158
  • [50] SOURCES OF ERROR IN MEASUREMENT OF OXYGEN PARTIAL-PRESSURE WITH GALVANIC SOLID ELECTROLYTE CELLS
    ULLMANN, H
    ZEITSCHRIFT FUR PHYSIKALISCHE CHEMIE-LEIPZIG, 1972, 250 (3-4): : 195 - &