A RETRIEVABLE NITINOL VENA-CAVA FILTER - EXPERIMENTAL AND INITIAL CLINICAL-RESULTS

被引:19
|
作者
NAKAGAWA, N [1 ]
CRAGG, AH [1 ]
SMITH, TP [1 ]
CASTANEDA, F [1 ]
BARNHART, WH [1 ]
DEJONG, SC [1 ]
机构
[1] UNIV IOWA HOSP & CLIN,COLL MED,DEPT MACROMOLEC CHEM,IOWA CITY,IA 52242
关键词
EMBOLISM; PULMONARY; VENAE-CAVAE; FILTERS;
D O I
10.1016/S1051-0443(94)71539-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The authors describe the properties of a new retrievable nitinol vena cava filter and report experimental and initial clinical results. MATERIALS AND METHODS: The filters, made of nitinol monofilament wire that forms a spiral cone and retrieval wire, were introduced through an indwelling 5.5-F transfemoral sheath into the infrarenal portion of the inferior vena cava in 10 sheep. In seven animals, four 4 x 30-mm radiopaque clots were injected below the filter to test its thrombus-trapping efficacy. Aspiration thrombectomy was then attempted, and the filter was removed. Follow-up venography was performed 1 week after placement in three other animals. After successful preclinical testing, the filter was implanted and retrieved in two patients. RESULTS: All 10 filters were successfully and easily placed in sheep. All filters were thrombus-free at follow-up venography. All clots injected in the iliac veins were trapped by the filter and successfully removed by means of aspiration thrombectomy. All 10 filters were retrieved without difficulty. Temporary filter implantation and retrieval were accomplished in two patients for 5 and 7 days. In one patient, infrafilter thrombus was aspirated. Perisheath thrombosis occurred in both patients. One patient subsequently underwent permanent filter placement. CONCLUSION: Temporary vena cava filtration is feasible. Potential advantages include easy placement, surveillance, and retrieval. One current limitation is pericatheter thrombosis, which may be eliminated by a less thrombogenic sheath.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [31] VENA-CAVA UMBRELLA FILTER - EXPERIMENTAL, HEMODYNAMIC AND EMBOLIZATION STUDIES
    HARJOLA, PT
    HOCKERSTEDT, K
    SCHEININ, TM
    STANDERTSKJOLDNORDENSTAM, CG
    TAHTI, E
    JOURNAL OF CARDIOVASCULAR SURGERY, 1975, 16 (06): : 626 - 631
  • [32] RESULTS OF VENA-CAVA LIGATION
    CRANLEY, JJ
    STRASSER, ES
    KRAUSE, RJ
    HAFNER, CD
    JOURNAL OF CARDIOVASCULAR SURGERY, 1972, 13 (05): : 403 - &
  • [33] SHORT-TERM PROPHYLAXIS OF PULMONARY-EMBOLISM BY USING A RETRIEVABLE VENA-CAVA FILTER
    DARCY, MD
    SMITH, TP
    HUNTER, DW
    CASTANEDAZUNIGA, W
    LUND, G
    AMPLATZ, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1986, 147 (04) : 836 - 838
  • [34] FILTER IN VENA-CAVA AND PULMONARY EMBOLISMS
    ROSEAU, E
    NOUVELLE PRESSE MEDICALE, 1972, 1 (19): : 1306 - &
  • [35] A NEW PERCUTANEOUS VENA-CAVA FILTER
    CRAGG, A
    LUND, G
    SALOMONOWITZ, E
    RYSAVY, J
    CASTANEDA, F
    CASTANEDAZUNIGA, W
    AMPLATZ, K
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1983, 141 (03) : 601 - 604
  • [36] INDICATION FOR VENA-CAVA FILTER IMPLANTATION
    MULLERWIEFEL, H
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1986, 369 : 489 - 492
  • [37] INFERIOR VENA-CAVA UMBRELLA FILTER
    MOBINUDDIN, K
    UTLEY, JR
    BRYANT, LR
    PROGRESS IN CARDIOVASCULAR DISEASES, 1975, 17 (05) : 391 - 399
  • [38] DISTAL MIGRATION OF VENA-CAVA FILTER
    VONGIZYCKI, AC
    GANNON, P
    VANTASSE.R
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1973, 224 (04): : 529 - 529
  • [39] BIDIRECTIONAL VENA-CAVA FILTER PLACEMENT
    KERR, A
    BOXER, DC
    JOURNAL OF VASCULAR SURGERY, 1995, 22 (04) : 501 - 504
  • [40] MIGRATION OF VENA-CAVA UMBRELLA FILTER
    JANSON, R
    LINDECKEN, KD
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1980, 133 (01): : 92 - 94