A RETRIEVABLE NITINOL VENA-CAVA FILTER - EXPERIMENTAL AND INITIAL CLINICAL-RESULTS

被引:19
|
作者
NAKAGAWA, N [1 ]
CRAGG, AH [1 ]
SMITH, TP [1 ]
CASTANEDA, F [1 ]
BARNHART, WH [1 ]
DEJONG, SC [1 ]
机构
[1] UNIV IOWA HOSP & CLIN,COLL MED,DEPT MACROMOLEC CHEM,IOWA CITY,IA 52242
关键词
EMBOLISM; PULMONARY; VENAE-CAVAE; FILTERS;
D O I
10.1016/S1051-0443(94)71539-6
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: The authors describe the properties of a new retrievable nitinol vena cava filter and report experimental and initial clinical results. MATERIALS AND METHODS: The filters, made of nitinol monofilament wire that forms a spiral cone and retrieval wire, were introduced through an indwelling 5.5-F transfemoral sheath into the infrarenal portion of the inferior vena cava in 10 sheep. In seven animals, four 4 x 30-mm radiopaque clots were injected below the filter to test its thrombus-trapping efficacy. Aspiration thrombectomy was then attempted, and the filter was removed. Follow-up venography was performed 1 week after placement in three other animals. After successful preclinical testing, the filter was implanted and retrieved in two patients. RESULTS: All 10 filters were successfully and easily placed in sheep. All filters were thrombus-free at follow-up venography. All clots injected in the iliac veins were trapped by the filter and successfully removed by means of aspiration thrombectomy. All 10 filters were retrieved without difficulty. Temporary filter implantation and retrieval were accomplished in two patients for 5 and 7 days. In one patient, infrafilter thrombus was aspirated. Perisheath thrombosis occurred in both patients. One patient subsequently underwent permanent filter placement. CONCLUSION: Temporary vena cava filtration is feasible. Potential advantages include easy placement, surveillance, and retrieval. One current limitation is pericatheter thrombosis, which may be eliminated by a less thrombogenic sheath.
引用
收藏
页码:507 / 512
页数:6
相关论文
共 50 条
  • [1] EXPERIMENTAL EVALUATION OF A RETRIEVABLE VENA-CAVA FILTER
    NAKAGAWA, N
    CRAGG, AH
    SMITH, TP
    CASTANEDA, F
    DEJONG, SC
    BARNHART, WH
    VASCULAR SURGERY, 1994, 28 (01): : 7 - 14
  • [2] CLINICAL-RESULTS OF SUPRARENAL PLACEMENT OF THE GREENFIELD VENA-CAVA FILTER
    STEWART, JR
    PEYTON, JWR
    CRUTE, SL
    GREENFIELD, LJ
    SURGERY, 1982, 92 (01) : 1 - 4
  • [3] EXPERIENCE WITH THE AMPLATZ RETRIEVABLE VENA-CAVA FILTER
    EPSTEIN, DH
    DARCY, MD
    HUNTER, DW
    COLEMAN, CC
    TADAVARTHY, SM
    MURRAY, PD
    CASTANEDAZUNIGA, WR
    AMPLATZ, K
    RADIOLOGY, 1989, 172 (01) : 105 - 110
  • [4] SIMON NITINOL INFERIOR VENA-CAVA FILTER - INITIAL CLINICAL-EXPERIENCE - WORK IN PROGRESS
    SIMON, M
    ATHANASOULIS, CA
    KIM, DS
    STEINBERG, FL
    PORTER, DH
    BYSE, BH
    KLESHINSKI, S
    GELLER, S
    ORRON, DE
    WALTMAN, AC
    RADIOLOGY, 1989, 172 (01) : 99 - 103
  • [5] Retrievable inferior vena cava filters: Initial clinical results
    Rosenthal, D
    Wellons, ED
    Lai, KM
    Bikk, A
    Henderson, VJ
    ANNALS OF VASCULAR SURGERY, 2006, 20 (01) : 157 - 165
  • [6] MIGRATION OF THE SIMON NITINOL VENA-CAVA FILTER TO THE CHEST
    LAPLANTE, JS
    CONTRACTOR, FM
    KIPROFF, PM
    KHOURY, MB
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1993, 160 (02) : 385 - 386
  • [7] COMPARATIVE INVITRO EVALUATION OF THE NITINOL INFERIOR VENA-CAVA FILTER
    PALESTRANT, AM
    PRINCE, M
    SIMON, M
    RADIOLOGY, 1982, 145 (02) : 351 - 355
  • [8] In vitro evaluation of a retrievable low-profile nitinol vena cava filter
    Bruckheimer, E
    Judelman, AG
    Bruckheimer, SD
    Tavori, I
    Naor, G
    Katzen, BT
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2003, 14 (04) : 469 - 474
  • [9] NEW RETRIEVABLE PERCUTANEOUS VENA-CAVA FILTER - EXPERIMENTAL IN-VITRO AND IN-VIVO EVALUATION
    NEUERBURG, J
    GUNTHER, RW
    RASSMUSSEN, E
    VORWERK, D
    TONN, K
    HANDT, S
    KUPPER, W
    HANSEN, JV
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1993, 16 (04) : 224 - 229
  • [10] In vivo evaluation of a retrievable vena cava filter - The Dibie-Musset filter: Experimental results
    Dibie, A
    Musset, D
    Heissler, M
    Fournet, JC
    Palau, R
    Laborde, F
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 21 (02) : 151 - 157