ROBUST DISTURBANCES REJECTION IN PUMPING STATIONS CONTROL FOR CENTRALIZED DRINKING WATER DISTRIBUTION SYSTEM

被引:0
|
作者
Dorofieiev, Yu. I. [1 ]
Lyubchyk, L. M. [1 ]
机构
[1] Natl Tech Univ, Kharkiv Polytechn Inst, Kharkov, Ukraine
关键词
drinking water distribution system; water inventory control; invariant ellipsoids method; Lyapunov's direct method; linear matrix inequality; semi-definite programming;
D O I
暂无
中图分类号
TP3 [计算技术、计算机技术];
学科分类号
0812 ;
摘要
An approach to solving the problem of stabilizing robust water inventory control synthesis for drinking water distribution system of a large city is proposed. The mathematical model of drinking water distribution system is presented in the form of a nonlinear discrete state-space model with time-delay. The technique of model matrix factorization describing the influence of nonlinear terms, which allowed to introduce structural constraints in the form of linear matrix inequalities, is proposed. To suppress the disturbances influence simulating unknown but bounded external demand, while ensuring robust stability of the closed-loop system, is used the invariant ellipsoids technique, which allowed to formulate the control problem in terms of linear matrix inequalities. As a result the control synthesis problem is reduced to a sequence of one-dimensional convex optimization problems and semi-definite programming. As an example, a fragment of the Kharkiv drinking water distribution system is consider.
引用
收藏
页码:164 / 173
页数:10
相关论文
共 50 条
  • [41] Disturbances rejection based on robust H∞ control for an aerial inertially stabilized platform
    Zhou Xiangyang
    Liu Xinyue
    Yang Chao
    [J]. PROCEEDINGS OF 2019 14TH IEEE INTERNATIONAL CONFERENCE ON ELECTRONIC MEASUREMENT & INSTRUMENTS (ICEMI), 2019, : 1396 - 1401
  • [42] CENTRALIZED AUTOMATIC SYSTEM FOR THE MONITORING AND CONTROL OF RADIO AND TELEVISION BROADCASTING STATIONS.
    Khazanov, A.Sh.
    Shislo, V.N.
    Scherbich, A.V.
    Korabchikov, V.D.
    Pashlovskiy, I.Yu.
    Solnechnaya, E.V.
    [J]. Telecommunications and Radio Engineering (English translation of Elektrosvyaz and Radiotekhnika), 1980, 34-35 (01): : 32 - 37
  • [43] Control of Loose Deposits in a Simulated Drinking Water Distribution System Using Ultrafiltration
    Zhang, Yongji
    Hou, Huimin
    Qiu, Mengyu
    Zhou, Lingling
    [J]. WATER, 2023, 15 (12)
  • [44] A Parallel Processing Packet Inspection by Centralized Multiple Robust Distribution System
    Vijayakumar, C.
    RajaRajeswari, B.
    Balasubramanian, C.
    [J]. 2015 2ND INTERNATIONAL CONFERENCE ON ELECTRONICS AND COMMUNICATION SYSTEMS (ICECS), 2015, : 1422 - 1425
  • [45] Biofilm control in drinking water distribution systems
    Gagnon, GA
    [J]. CHLORINE DIOXIDE: THE STATE OF SCIENCE, REGULATORY, ENVIRONMENTAL ISSUES, AND CASE HISTORIES, 2002, : 71 - 86
  • [46] Robust control of a mobile robot system with kinematic disturbances
    Dixon, WE
    Dawson, DM
    Zergeroglu, E
    [J]. PROCEEDINGS OF THE 2000 IEEE INTERNATIONAL CONFERENCE ON CONTROL APPLICATIONS, 2000, : 437 - 442
  • [47] Can phosphorus control be a feasible option to control regrowth in Tokyo drinking water distribution system?
    Sathasivan, A
    Ohgaki, S
    Otaki, M
    [J]. WATER SUPPLY, VOL 16, NOS 3/4 - 1998: IWSA INTERNATIONAL SPECIALIZED CONFERENCE, 1998, 16 (3-4): : 249 - 249
  • [48] Study and Control of Photovoltaic Water Pumping System
    Khlifi, Mohamed Arbi
    [J]. JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY, 2016, 11 (01) : 117 - 124
  • [49] Water Pumping System with PLC and Frequency Control
    Ali, Akayleh
    AlSoud, Mohammed
    Abdallah, Essam
    Addallah, Salah
    [J]. JORDAN JOURNAL OF MECHANICAL AND INDUSTRIAL ENGINEERING, 2009, 3 (03): : 216 - 220
  • [50] Control water level of a photovoltaic pumping system
    Khiareddine, Abla
    Ben Salah, Chokri
    Mimouni, Mohamed Faouzi
    [J]. 2013 INTERNATIONAL CONFERENCE ON CONTROL, DECISION AND INFORMATION TECHNOLOGIES (CODIT), 2013, : 435 - 440