BEAT-BY-BEAT FOREARM BLOOD-FLOW WITH DOPPLER ULTRASOUND AND STRAIN-GAUGE PLETHYSMOGRAPHY

被引:73
|
作者
TSCHAKOVSKY, ME
SHOEMAKER, JK
HUGHSON, RL
机构
[1] Dept. of Kinesiology, Univ. of Waterloo, Waterloo
关键词
VENOUS OCCLUSION STRAIN-GAUGE PLETHYSMOGRAPHY; EXERCISE;
D O I
10.1152/jappl.1995.79.3.713
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Simultaneous Doppler ultrasound estimates of brachial artery mean blood velocity (MBV) and venous occlusion strain-gauge plethysmography measures of forearm blood flow (FBF) were performed to determine the beat-by-beat relationship between the two methods and provide a method for flow calibration of Doppler MBV estimates. Such a calibration of Doppler MBV eliminates the need for knowledge of vessel cross-sectional area and angle of insonation while allowing for the quantification of limb blood flow. Six healthy subjects (5 men and 1 woman) performed 40 s of isometric forearm contraction at 35% maximal voluntary contraction with arterial inflow occluded. This resulted in elevated blood flow on relaxation and cuff deflation, and simultaneous beat-by-beat Doppler MBV and strain-gauge FBF measurements were then made over a period of 2-3 min as flow gradually decreased to resting levels. The r(2) values for the fitted regression lines over a wide range of flows ranged from 0.87 to 0.98, and the mean square error terms ranged from 0.88 to 3.07 ml . 100 ml(-1) . min(-1). Significant day-to-day variation of the fitted regression parameters within subjects indicated that quantitative estimates of FBF from Doppler MBV require a calibration to be performed for each experiment. The finding of a strong linear relationship between Doppler MBV and venous occlusion strain-gauge plethysmography, as well as the marked beat-by-beat effect of cuff inflation on blood flow, confirms the importance of calibration on the same beats, not on adjacent segments of beats.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 50 条
  • [31] INFLUENCE OF ULTRASOUND ON THE BLOOD-FLOW THROUGH THE FOREARM
    TRNAVSKY, G
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1980, 130 (15-1) : 539 - 541
  • [32] Evaluation of influence of blood pressure and anthropometric indices on peripheral blood flow estimated by strain-gauge plethysmography in subjectively healthy men
    Neubauer-Geryk, Jolanta
    Bieniaszewski, Leszek
    Kruszewski, Piotr
    Swiatek, Hanna
    Kunicka, Katarzyna
    Swierblewska, Ewa
    Miszkowska, Eliza
    Drzazga, Edyta
    Kaczmarek, Przybyslawa
    Wyrzykowski, Bogdan
    ARTERIAL HYPERTENSION, 2006, 10 (01): : 20 - 29
  • [33] MEASUREMENT OF BLOOD-FLOW WITH DOPPLER ULTRASOUND
    KLEPPER, JR
    MEDICAL PHYSICS, 1986, 13 (04) : 621 - 621
  • [34] DIAGNOSIS OF DEEP-VEIN THROMBOSIS BY COMBINATION OF DOPPLER ULTRASOUND FLOW EXAMINATION AND STRAIN-GAUGE PLETHYSMOGRAPHY - AN ALTERNATIVE TO VENOGRAPHY ONLY IN PARTICULAR CONDITIONS DESPITE IMPROVED ACCURACY OF THE DOPPLER METHOD
    BOUNAMEAUX, H
    KRAHENBUHL, B
    VUKANOVIC, S
    THROMBOSIS AND HAEMOSTASIS, 1982, 47 (02) : 141 - 144
  • [35] BEAT-TO-BEAT RELATIONSHIPS BETWEEN BLOOD-PRESSURE AND CEREBRAL BLOOD-FLOW VELOCITY IN THE PREMATURE-INFANT
    BIGNALL, S
    KITNEY, RI
    RIVERS, RPA
    STRAUGHAN, K
    JOURNAL OF PHYSIOLOGY-LONDON, 1989, 413 : P25 - P25
  • [36] SIMULTANEOUS BLOOD FLOW MEASUREMENTS BY WATER AND STRAIN GAUGE PLETHYSMOGRAPHY
    DAHN, I
    HALLBOOK, T
    SCANDINAVIAN JOURNAL OF CLINICAL & LABORATORY INVESTIGATION, 1970, 25 (04): : 419 - &
  • [37] PENILE BLOOD FLOW DETERMINATION BY MERCURY STRAIN GAUGE PLETHYSMOGRAPHY
    BRITT, DB
    KEMMERER, WT
    ROBISON, JR
    INVESTIGATIVE UROLOGY, 1971, 8 (06): : 673 - &
  • [38] THE REPRODUCIBILITY OF LIMB BLOOD-FLOW MEASUREMENTS IN HUMAN VOLUNTEERS AT REST AND AFTER EXERCISE BY USING MERCURY-IN-SILASTIC STRAIN-GAUGE PLETHYSMOGRAPHY UNDER STANDARDIZED CONDITIONS
    ROBERTS, DH
    TSAO, Y
    BRECKENRIDGE, AM
    CLINICAL SCIENCE, 1986, 70 (06) : 635 - 638
  • [39] A COMPARISON OF THE STRAIN-GAUGE AND THE DOHN AIR-FILLED PLETHYSMOGRAPHS FOR BLOOD-FLOW MEASUREMENTS IN THE HUMAN CALF
    EICKHOFF, JH
    KJAER, L
    SIGGAARDANDERSEN, J
    ACTA CHIRURGICA SCANDINAVICA, 1980, : 15 - 20
  • [40] SOME CRITICAL CONSIDERATIONS ON STRAIN-GAUGE PLETHYSMOGRAPHY IN POST-ISCHEMIC FLOW MEASUREMENTS.
    Gizdulich, P.
    Scarpelli, P.T.
    Automedica, 1984, 5 (01): : 33 - 35