The success rate and safety of internal jugular vein cannulation using anatomical landmark technique in patients undergoing cardiothoracic surgery

被引:13
|
作者
Tempe, Deepak K. [1 ,2 ]
Virmani, Sanjula [1 ,2 ]
Agarwal, Jyotsna [1 ,2 ]
Hemrajani, Manisha [1 ,2 ]
Satyarthy, Subodh [3 ]
Minhas, Harpreet Singh [3 ]
机构
[1] GB Pant Hosp, Dept Anaesthesiol, New Delhi, India
[2] GB Pant Hosp, Dept Intens Care, New Delhi, India
[3] GB Pant Hosp, Dept Cardiothorac Surg, New Delhi, India
关键词
Cardiothoracic surgical patients; Internal jugular vein cannulation; Landmark-guided IJV cannulation;
D O I
10.4103/0971-9784.105364
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Aims and objectives: Landmark-guided internal jugular vein (IJV) cannulation is a basic procedure, which every anesthetist is expected to acquire. A successful first attempt is desirable as each attempt increases the risk of complications. The present study is an analysis of 976 IJV cannulations performed in adults undergoing cardiothoracic surgery. Materials and Methods: The IJV was cannulated with a triple lumen catheter using the anatomical landmarks. The following data were recorded: Patient demographics, age, sex, body mass index, diagnosis, operative procedure, operator (resident/consultant), site of cannulation (central approach, right IJV, left IJV, external jugular vein), number of attempts and duration of cannulation, length of insertion of the catheter, number of correct placements on X-ray and any complications. Results: The success rate of IJV cannulation was 100%. In 809 (82.9%) patients, cannulation was performed in the first attempt. Residents performed 792 cannulations and the consultants performed 184 cannulations. In 767 patients, the residents were successful in inserting the catheter and in 25 they failed after 5 attempts, hence, they were cannulated by the consultant. The time taken for insertion of the catheter was 6.89 3.2 minutes. Carotid artery puncture was the most common complication, it occurred in 22 (2.3%) patients. Conclusion: IJV cannulation with landmark technique is highly successful with minimal complications in the adult patients undergoing cardiothoracic surgery. Basic training of cannulating the IJV by landmark technique should be imparted to all the traines as ultrasound may not be available in all locations.
引用
收藏
页码:16 / 20
页数:5
相关论文
共 50 条
  • [31] Comparative evaluation of success of ultrasound-guided internal jugular vein cannulation using needle with guard: A randomized, controlled study
    Arya, Vikas
    Gupta, Devendra
    Agarwal, Anil
    Paul, Mekhala
    Mishra, Prabhaker
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2020, 36 (01) : 57 - 61
  • [32] EVALUATION OF THE INCIDENCE OF CENTRAL VENOUS THROMBOSIS FOLLOWING CANNULATION OF THE RIGHT INTERNAL JUGULAR VEIN IN PATIENTS AFTER CARDIAC SURGERY
    Tizard, K.
    Prenter, A.
    Al-Rawi, O.
    INTENSIVE CARE MEDICINE, 2014, 40 : S45 - S45
  • [33] Anatomical features of the right internal jugular vein in infants and young children undergoing heart surgery for congenital disease: comparison between cyanotic and noncyanotic patients
    Morimoto, Yuji
    Hisano, Kenjiro
    Takita, Koichi
    Hashimoto, Toshikazu
    JOURNAL OF ANESTHESIA, 2008, 22 (01) : 1 - 6
  • [34] Anatomical features of the right internal jugular vein in infants and young children undergoing heart surgery for congenital disease: comparison between cyanotic and noncyanotic patients
    Yuji Morimoto
    Kenjiro Hisano
    Koichi Takita
    Toshikazu Hashimoto
    Journal of Anesthesia, 2008, 22 : 1 - 6
  • [35] Femoral Vein Cannulation Performed by Residents: A Comparison Between Ultrasound-Guided and Landmark Technique in Infants and Children Undergoing Cardiac Surgery
    Aouad, Marie T.
    Kanazi, Ghassan E.
    Abdallah, Faraj W.
    Moukaddem, Farah H.
    Turbay, Massud J.
    Obeid, Mounir Y.
    Siddik-Sayyid, Sahar M.
    ANESTHESIA AND ANALGESIA, 2010, 111 (03): : 724 - 728
  • [36] Does ultrasound imaging before puncture facilitate internal jugular vein cannulation? Prospective randomized comparison with landmark-guided puncture in ventilated patients
    Hayashi, H
    Amano, M
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2002, 16 (05) : 572 - 575
  • [37] Ultrasound-guided catheterization of the internal jugular vein in oncologic patients; Comparison with the classical anatomic landmark technique: A prospective study
    Serafimidis, Konstantinos
    Sakorafas, George H.
    Konstantoudakis, George
    Petropoulou, Konstantina
    Giannopoulos, George P.
    Danias, Nikolaos
    Peros, George
    Safioleas, Michael
    INTERNATIONAL JOURNAL OF SURGERY, 2009, 7 (06) : 526 - 528
  • [38] Percutaneous placement of central venous catheters: Comparing the anatomical landmark method with the radiologically guided technique for central venous catheterization through the internal jugular vein in emergent hemodialysis patients
    Koroglu, M
    Demir, M
    Koroglu, BK
    Sezer, MT
    Akhan, O
    Yildiz, H
    Yavuz, L
    Baykal, B
    Oyar, O
    ACTA RADIOLOGICA, 2006, 47 (01) : 43 - 47
  • [39] Real-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients
    Dimitrios Karakitsos
    Nicolaos Labropoulos
    Eric De Groot
    Alexandros P Patrianakos
    Gregorios Kouraklis
    John Poularas
    George Samonis
    Dimosthenis A Tsoutsos
    Manousos M Konstadoulakis
    Andreas Karabinis
    Critical Care, 10
  • [40] Eal-time ultrasound-guided catheterisation of the internal jugular vein: a prospective comparison with the landmark technique in critical care patients
    Karakitsos, Dimitrios
    Labropoulos, Nicolaos
    De Groot, Eric
    Patrianakos, Alexandros P.
    Kouraklis, Gregorios
    Poularas, John
    Samonis, George
    Tsoutsos, Dimosthenis A.
    Konstadoulakis, Manousos M.
    Karabinis, Andreas
    CRITICAL CARE, 2006, 10 (06):