BIOMECHANICAL EVALUATION OF A BIODEGRADABLE COMPOSITE AS AN ADJUNCT TO INTERNAL-FIXATION OF PROXIMAL FEMUR FRACTURES

被引:23
|
作者
WITSCHGER, PM
GERHART, TN
GOLDMAN, JB
EDSBERG, LE
HAYES, WC
机构
[1] BETH ISRAEL HOSP,CHARLES A DANA RES INST,DEPT ORTHOPAED SURG,ORTHOPAED BIOMECH LAB,BOSTON,MA 02215
[2] HARVARD UNIV,SCH MED,BOSTON,MA 02115
关键词
HIP FRACTURE; OSTEOPOROSIS; INTERNAL FIXATION; BIOMATERIALS;
D O I
10.1002/jor.1100090107
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Internal fixation of comminuted unstable fractures of the severely osteoporotic proximal femur is sometimes supplemented with polymethylmethacrylate (PMMA). We here report an in vitro biomechanical evaluation of a biodegradable particulate composite that might be used for similar purposes. The composite includes a matrix phase consisting of a hydrolyzable prepolymer [polypropylene fumarate (PPF)] cross-linked with methacrylate monomer, and a particulate phase consisting of tricalcium phosphate and calcium carbonate. We implanted dynamic hip screws in 22 cadaveric proximal femora and measured the yield load for an oblique force applied to the femoral head. The hip screws were then reinforced with either PMMA or the PPF composite and tested again. On the basis of analysis of variance, the average increases in yield load for PMMA and PPF reinforcement of 1,750 and 1,130 N were statistically significant (p < 0.00005), suggesting that both materials enhance congruence between implant and bone and thereby increase the projected load-bearing area of the implant. The increase in yield force with PMMA was slightly higher than the increase with PPF (p < 0.05), but both values after reinforcement were close (3,790 +/- 561 N for PMMA vs. 3,240 +/- 669 N for PPF). If we can demonstrate that appropriate rates of degradation, bony ingrowth, and static and fatigue properties can be achieved in vivo with this system, our data suggest that this PPF composite may have potential as an adjunct to the internal fixation of unstable fractures of the osteoporotic hip.
引用
收藏
页码:48 / 53
页数:6
相关论文
共 50 条
  • [31] A biomechanical study on proximal plate fixation techniques in periprosthetic femur fractures
    Lenz, Mark
    Perren, Stephan M.
    Gueorguiev, Boyko
    Richards, Robert G.
    Hofmann, Gunther O.
    Fernandez dell'Oca, Alberto
    Hoentzsch, Dankward
    Windolf, Markus
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2014, 45 : S71 - S75
  • [32] Screw-blade fixation systems in proximal femur fractures: a biomechanical evaluation. (8300)
    Schopper, Clemens
    Keck, Katharina
    Beeres, Frank
    Link, Bjoern-Christian
    Babst, Reto
    Nebelung, Sven
    Zderic, Ivan
    Gueorguiev, Boyko
    Knobe, Matthias
    SWISS MEDICAL WEEKLY, 2020, : S21 - S21
  • [33] INTERNAL-FIXATION OF HAND FRACTURES
    BARTON, N
    JOURNAL OF HAND SURGERY-BRITISH AND EUROPEAN VOLUME, 1989, 14B (02): : 139 - 142
  • [34] RIGID INTERNAL-FIXATION OF FRACTURES
    LAROS, GS
    SPIEGEL, PG
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1979, (138) : 2 - 3
  • [35] INTERNAL-FIXATION OF JUVENILE FRACTURES
    KUNER, EH
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1976, 342 : 291 - 298
  • [36] INTERNAL-FIXATION OF PATELLAR FRACTURES
    WEBER, BG
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1973, 334 : 978 - 978
  • [37] INTERNAL-FIXATION OF MALAR FRACTURES
    ONKEN, HD
    PLASTIC AND RECONSTRUCTIVE SURGERY, 1990, 85 (03) : 481 - 481
  • [38] INTERNAL-FIXATION OF WRIST FRACTURES
    BROOKS, D
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1978, 71 (06) : 462 - 462
  • [39] INTERNAL-FIXATION OF MALLEOLAR FRACTURES
    WEBER, BG
    LANGENBECKS ARCHIV FUR CHIRURGIE, 1973, 334 : 977 - 977
  • [40] TRAINING IN INTERNAL-FIXATION OF FRACTURES
    GRIFFITHS, JC
    BMJ-BRITISH MEDICAL JOURNAL, 1978, 2 (6152): : 1615 - 1616