Dual-Source Swept-Source Optical Coherence Tomography Reconstructed on Integrated Spectrum

被引:8
|
作者
Chang, Shoude [1 ]
Mao, Youxin [1 ]
Flueraru, Costel [1 ]
机构
[1] Natl Res Council Canada, Inst Microstruct Sci, 1200 Montreal Rd, Ottawa, ON K1A 0R6, Canada
关键词
D O I
10.1155/2012/565823
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Dual-source swept-source optical coherence tomography (DS-SSOCT) has two individual sources with different central wavelengths, linewidth, and bandwidths. Because of the difference between the two sources, the individually reconstructed tomograms from each source have different aspect ratio, which makes the comparison and integration difficult. We report a method to merge two sets of DS-SSOCT raw data in a common spectrum, on which both data have the same spectrum density and a correct separation. The reconstructed tomographic image can seamlessly integrate the two bands of OCT data together. The final image has higher axial resolution and richer spectroscopic information than any of the individually reconstructed tomography image.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] EN FACE IMAGING OF PACHYCHOROID SPECTRUM DISORDERS WITH SWEPT-SOURCE OPTICAL COHERENCE TOMOGRAPHY
    Dansingani, Kunal K.
    Balaratnasingam, Chandrakumar
    Naysan, Jonathan
    Freund, K. Bailey
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2016, 36 (03): : 499 - 516
  • [22] Choroidal thickness in the era of swept-source optical coherence tomography
    Agarwal, Aniruddha
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (02) : 256 - 257
  • [23] Swept-source optical coherence tomography imaging of the retinochoroid and beyond
    Vira, Jayesh
    Marchese, Alessandro
    Singh, Rohan Bir
    Agarwal, Aniruddha
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (05) : 413 - 426
  • [24] Swept-source optical coherence tomography findings in peripheral drusen
    Kumar, Vinod
    Tewari, Ruchir
    Chandra, Parijat
    Kumar, Atul
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2016, 64 (12) : 930 - 931
  • [25] Phase-stability optimization of swept-source optical coherence tomography
    Moon, Sucbei
    Chen, Zhongping
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (11): : 5280 - 5295
  • [26] Delineation of an oral cancer lesion with swept-source optical coherence tomography
    Tsai, Meng-Tsan
    Lee, Hsiang-Chieh
    Lu, Chih-Wei
    Wang, Yih-Ming
    Lee, Cheng-Kuang
    Yang, C. C.
    Chiang, Chun-Ping
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (04)
  • [27] 80 degree field of view swept-source optical coherence tomography
    Meyer-Hilberg, Leila
    Qui, Yue
    Williams, Rick
    Bello, Simon
    Howard, Doug
    Arain, Muzammil A.
    Moghimi, Atoosa
    Straub, Jochen
    Schmoll, Tilman
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [28] Comparative analysis of 2 swept-source optical coherence tomography biometers
    Sabatino, Francesco
    Matarazzo, Francesco
    Findl, Oliver
    Maurino, Vincenzo
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2019, 45 (08): : 1124 - 1129
  • [29] Cataractous mountain on the corneal horizon: Swept-source optical coherence tomography
    Choudhry, Netan
    Golding, John
    Rao, Rajesh C.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2016, 42 (07): : 1097 - 1097
  • [30] Swept-source optical coherence tomography features of regressed macular retinoblastoma
    Damodaran, Sourav
    Bajaj, Mandeep S.
    Sharma, Pradeep
    Kumar, Atul
    Chawla, Rohan
    Pujari, Amar
    Garg, Gaurav
    Temkar, Shreyas
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2019, 67 (12) : 2013 - 2018