STUDY OF NONCOVALENT ENZYME-INHIBITOR COMPLEXES AND METAL-BINDING STOICHIOMETRY OF MATRILYSIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY

被引:40
|
作者
FENG, R
CASTELHANO, AL
BILLEDEAU, R
YUAN, ZY
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL,PQ H4P 2R2,CANADA
[2] SYNTEX CANADA,MISSISSAUGA,ON,CANADA
关键词
D O I
10.1016/1044-0305(95)00548-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization mass spectrometry (ESI-MS) was used to study the noncovalent metallo-enzyme-inhibitor complexes of matrilysin (a matrix metalloproteinase of mass 18,720 u) under gentle experimental conditions and to determine the metal ion association stoichiometries in both the free enzyme and the complexes. The metal association stoichiometries of the free matrilysin were found to be highly sensitive to solution pH changes. At pH 2.2 the enzyme existed as metal-free apo-matrilysin and was not capable of binding an inhibitor. At pH 4.5-7.0 the enzyme associated specifically with zinc and calcium cations and became active in inhibitor binding. Although the stoichiometries of the metal cofactors varied (zero to two zinc and/or calcium ions) in the free enzyme dependent on solution pH, the predominant form of the enzyme-inhibitor complexes in the pH range of 4.5-7.0, in contrast, always had the metal association stoichiometry of 2Zn + 2Ca, which was the same stoichiometry the most active free metallo-enzyme had at the optimal pH of 7. At the activity onset FH of 4.5 matrilysin existed mostly as apo-enzyme (but in a conformation different from the denatured one at pH 2.2) and bound to an inhibitor slowly (time constant similar to 2.5 min) to form the noncovalent metallo-enzyme-inhibitor complex. Of the two inhibitors studied, the one with the higher solution binding constant also produced larger ion signals for the noncovalent complex in the solvent-free gas phase, which pointed to the feasibility of the use of ESI-MS for inhibitor screening studies.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 50 条
  • [21] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF SPHINGANINE ANALOG MYCOTOXINS
    CALDAS, ED
    JONES, AD
    WINTER, CK
    WARD, B
    GILCHRIST, DG
    ANALYTICAL CHEMISTRY, 1995, 67 (01) : 196 - 207
  • [22] CHARACTERIZATION OF NONCOVALENT COMPLEXES BY ELECTROSPRAY MASS-SPECTROMETRY
    JAQUINOD, M
    LEIZE, E
    POTIER, N
    ALBRECHT, AM
    SHANZER, A
    VANDORSSELAER, A
    TETRAHEDRON LETTERS, 1993, 34 (17) : 2771 - 2774
  • [23] SOME NEUROCHEMICAL APPLICATIONS OF ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    OLIVER, RWA
    GREEN, BN
    BIOCHEMICAL SOCIETY TRANSACTIONS, 1994, 22 (01) : 131 - 135
  • [24] DOES THE OBSERVATION OF NONCOVALENT COMPLEXES BETWEEN BIOMOLECULES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY NECESSARILY REFLECT SPECIFIC SOLUTION INTERACTIONS
    APLIN, RT
    ROBINSON, CV
    SCHOFIELD, CJ
    WESTWOOD, NJ
    JOURNAL OF THE CHEMICAL SOCIETY-CHEMICAL COMMUNICATIONS, 1994, (20) : 2415 - 2417
  • [25] ELECTROSPRAY-IONIZATION WITH FOURIER-TRANSFORM MASS-SPECTROMETRY
    WILLIAMS, ER
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (06) : 247 - 251
  • [26] GEOPORPHYRIN ANALYSIS USING ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    VANBERKEL, GJ
    RAMSEY, RS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 10 - GEOC
  • [27] EXPANDING THE UNDERSTANDING AND UTILITY OF ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    VANBERKEL, GJ
    MCLUCKEY, SA
    GLISH, GL
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1992, 204 : 77 - ANYL
  • [28] ANALYSIS OF THE ION-BINDING SITES OF CALMODULIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    LAFITTE, D
    CAPONY, JP
    GRASSY, G
    HAIECH, J
    CALAS, B
    BIOCHEMISTRY, 1995, 34 (42) : 13825 - 13832
  • [29] AN ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY STUDY OF COPPER ADDUCTS OF PROTONATED UBIQUITIN
    JIAO, CQ
    FREISER, BS
    CARR, SR
    CASSADY, CJ
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (06) : 521 - 524
  • [30] EVALUATION OF HISTONE SEQUENCE AND MODIFICATIONS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY AND TANDEM MASS-SPECTROMETRY
    EDMONDS, CG
    LOO, JA
    SMITH, RD
    FUCIARELLI, AF
    THRALL, BD
    MORRIS, JE
    SPRINGER, DL
    JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH, 1993, 40 (2-3): : 159 - 159