STUDY OF NONCOVALENT ENZYME-INHIBITOR COMPLEXES AND METAL-BINDING STOICHIOMETRY OF MATRILYSIN BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY

被引:40
|
作者
FENG, R
CASTELHANO, AL
BILLEDEAU, R
YUAN, ZY
机构
[1] NATL RES COUNCIL CANADA,BIOTECHNOL RES INST,MONTREAL,PQ H4P 2R2,CANADA
[2] SYNTEX CANADA,MISSISSAUGA,ON,CANADA
关键词
D O I
10.1016/1044-0305(95)00548-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Electrospray ionization mass spectrometry (ESI-MS) was used to study the noncovalent metallo-enzyme-inhibitor complexes of matrilysin (a matrix metalloproteinase of mass 18,720 u) under gentle experimental conditions and to determine the metal ion association stoichiometries in both the free enzyme and the complexes. The metal association stoichiometries of the free matrilysin were found to be highly sensitive to solution pH changes. At pH 2.2 the enzyme existed as metal-free apo-matrilysin and was not capable of binding an inhibitor. At pH 4.5-7.0 the enzyme associated specifically with zinc and calcium cations and became active in inhibitor binding. Although the stoichiometries of the metal cofactors varied (zero to two zinc and/or calcium ions) in the free enzyme dependent on solution pH, the predominant form of the enzyme-inhibitor complexes in the pH range of 4.5-7.0, in contrast, always had the metal association stoichiometry of 2Zn + 2Ca, which was the same stoichiometry the most active free metallo-enzyme had at the optimal pH of 7. At the activity onset FH of 4.5 matrilysin existed mostly as apo-enzyme (but in a conformation different from the denatured one at pH 2.2) and bound to an inhibitor slowly (time constant similar to 2.5 min) to form the noncovalent metallo-enzyme-inhibitor complex. Of the two inhibitors studied, the one with the higher solution binding constant also produced larger ion signals for the noncovalent complex in the solvent-free gas phase, which pointed to the feasibility of the use of ESI-MS for inhibitor screening studies.
引用
收藏
页码:1105 / 1111
页数:7
相关论文
共 50 条
  • [2] OBSERVATION OF NONCOVALENT COMPLEXES TO THE AVIDIN TETRAMER BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    SCHWARTZ, BL
    LIGHTWAHL, KJ
    SMITH, RD
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1994, 5 (03) : 201 - 204
  • [3] NONCOVALENT ASSOCIATIONS OF TRANSITION-METAL COMPLEXES WITH OLIGONUCLEOTIDE DUPLEXES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    HARMS, AC
    LIGHTWAHL, KJ
    SMITH, RD
    IBARTON, JK
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 34 - ANYL
  • [4] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY INTERFACE EFFECTS ON NONCOVALENT BIOCHEMICAL-COMPLEXES
    LIGHTWAHL, KJ
    SCHWARTZ, BL
    SMITH, RD
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 36 - ANYL
  • [5] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    EDMONDS, CG
    SMITH, RD
    METHODS IN ENZYMOLOGY, 1990, 193 : 412 - 431
  • [6] OBSERVATION OF DUPLEX DNA-DRUG NONCOVALENT COMPLEXES BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    GALE, DC
    GOODLETT, DR
    LIGHTWAHL, KJ
    SMITH, RD
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1994, 116 (13) : 6027 - 6028
  • [7] THE STUDY OF NONCOVALENT STREPTAVIDIN PROTEIN COMPLEXES AT HIGH M-Z BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    SCHWARTZ, BL
    BRUCE, JE
    HOFSTADLER, SA
    ROCKWOOD, AL
    ANDERSON, GA
    SMITH, RD
    CHILKOTI, A
    STAYTON, PS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 33 - ANYL
  • [8] ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY OF BIOTIN BINDING TO STREPTAVIDIN
    ECKART, K
    SPIESS, J
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1995, 6 (10) : 912 - 919
  • [9] CALCIUM STOICHIOMETRY DETERMINATION FOR CALCIUM-BINDING PROTEINS BY ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    HU, PF
    YE, QZ
    LOO, JA
    ANALYTICAL CHEMISTRY, 1994, 66 (23) : 4190 - 4194
  • [10] STUDYING PROTEIN COMPLEXES WITH ELECTROSPRAY-IONIZATION MASS-SPECTROMETRY
    LOO, JA
    HU, PF
    LOO, RRO
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1994, 207 : 102 - ANYL