DIAGNOSTIC-ACCURACY EVALUATION USING ROC CURVE ANALYSIS

被引:29
|
作者
HUGUET, J [1 ]
CASTINEIRAS, MJ [1 ]
FUENTESARDERIU, X [1 ]
机构
[1] HOSP PRINCEPS ESPANYA,SERV BIOQUIM CLIN,E-08907 LHOSPITALET LLOBR,SPAIN
关键词
AREA UNDER THE ROC CURVE; CUTOFF VALUES; DIAGNOSTIC SENSITIVITY; DIAGNOSTIC SPECIFICITY; DISCRIMINANT CAPACITY;
D O I
10.3109/00365519309092573
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The diagnostic accuracy of a biochemical quantity is inversely related to the overlapping zone between the values of the population suffering from a disease and the population which does not. The ROC curves are an indirect measure of the overlapping zone between both populations. Specimens (plasma and urine) taken from 928 patients with symptoms of acute abdominal pain were used and the catalytic concentration of alpha-amylase, pancreatic alpha-amylase and triacylglycerol lipase (determined by two methods) were measured. Definitive diagnosis was obtained by following the directives of expert groups on the evaluation of diagnostic tests. Diagnostic accuracy was characterized by calculating the diagnostic sensitivity and specificity, by representing the ROC curves and by quantifying the areas under the ROC curves. The catalytic concentration of pancreatic alpha-amylase in plasma was the quantity with a greater area under the ROC curve (A = 0.9740) and then the one which had greatest diagnostic accuracy. If we considered the upper limit of the reference interval to be the cut-off value, the catalytic concentration of pancreatic alpha-amylase in plasma had a diagnostic sensitivity and specificity values of 0.96 and 0.88 respectively for the acute pancreatitis.
引用
收藏
页码:693 / 699
页数:7
相关论文
共 50 条
  • [1] ROC ANALYSIS - ASSESSMENT OF DIAGNOSTIC-ACCURACY IN THE LABORATORY
    ZWEIG, MH
    LABORATORY MEDICINE, 1991, 22 (10) : 708 - 711
  • [2] AN EVALUATION OF THE DIAGNOSTIC-ACCURACY OF PATHFINDER
    HECKERMAN, DE
    NATHWANI, BN
    COMPUTERS AND BIOMEDICAL RESEARCH, 1992, 25 (01): : 56 - 74
  • [3] Biomarker assessment in ROC curve analysis using the length of the curve as an index of diagnostic accuracy: the binormal model framework
    Alba M. Franco-Pereira
    Christos T. Nakas
    M. Carmen Pardo
    AStA Advances in Statistical Analysis, 2020, 104 : 625 - 647
  • [4] Biomarker assessment in ROC curve analysis using the length of the curve as an index of diagnostic accuracy: the binormal model framework
    Franco-Pereira, Alba M.
    Nakas, Christos T.
    Pardo, M. Carmen
    ASTA-ADVANCES IN STATISTICAL ANALYSIS, 2020, 104 (04) : 625 - 647
  • [5] EVALUATION OF DIAGNOSTIC-ACCURACY IN THE CLINICAL SETTING
    RAZ, E
    COHEN, S
    BENBASSAT, J
    ISRAEL JOURNAL OF MEDICAL SCIENCES, 1987, 23 (12): : 1177 - 1180
  • [6] Evaluation of Diagnostic Accuracy and its Standard Error using Constant Shape Weibull Mixture ROC Curve
    Pundir, Sudesh
    Azharruddin
    PAKISTAN JOURNAL OF STATISTICS AND OPERATION RESEARCH, 2016, 12 (04) : 739 - 751
  • [7] PROSPECTIVE EVALUATION OF THE DIAGNOSTIC-ACCURACY OF LIVER ULTRASONOGRAPHY
    DEBONGNIE, JC
    PAULS, C
    FIEVEZ, M
    WIBIN, E
    GUT, 1981, 22 (02) : 130 - 135
  • [8] ROC analysis for diagnostic accuracy of fracture by using different monitors
    Liang, Zhigang
    Li, Kuncheng
    Yang, Xiaolin
    Du, Xiangying
    Liu, Jiabin
    Zhao, Xin
    Qi, Xiangdong
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (03) : 276 - 278
  • [9] ROC Analysis for Diagnostic Accuracy of Fracture by Using Different Monitors
    Zhigang Liang
    Kuncheng Li
    Xiaolin Yang
    Xiangying Du
    Jiabin Liu
    Xin Zhao
    Xiangdong Qi
    Journal of Digital Imaging, 2006, 19 : 276 - 278
  • [10] THROMBOLYSIS AND DIAGNOSTIC-ACCURACY
    HUSSAIN, A
    GEDLING, P
    PRESCOTT, RWG
    MCCULLOCH, AJ
    JOURNAL OF THE ROYAL SOCIETY OF MEDICINE, 1994, 87 (09) : 571 - 571