DOSIMETRY CONSIDERATIONS FOR THE HIGH-ENERGY PHOTON ELECTRON ENVIRONMENT OF HERMES .3. IMPLICATIONS FOR EXPERIMENTS AND MODELING

被引:7
|
作者
BEUTLER, DE [1 ]
HALBLEIB, JA [1 ]
SANFORD, TWL [1 ]
FEHL, DL [1 ]
KNOTT, DP [1 ]
机构
[1] TECH SUPPORT CORP,ALBUQUERQUE,NM 87185
关键词
D O I
10.1109/23.124170
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Measurements of energy deposition as a function of equilibrator thickness and position in the HERMES III radiation field are compared to ITS code predictions. These measurements demonstrate the combined photon/electron nature of the radiation field and the importance of the electron field in both measurements and calculations.
引用
收藏
页码:1736 / 1745
页数:10
相关论文
共 50 条
  • [1] HIGH-ENERGY PHOTON AND ELECTRON DOSIMETRY WITH TLD MATERIALS
    LAHTINEN, T
    KOSUNEN, A
    PUURUNEN, H
    VAINIO, P
    MEDICAL PHYSICS, 1984, 11 (03) : 384 - 384
  • [2] Comparison of high-energy photon and electron dosimetry for various dosimetry protocols
    Araki, F
    Kubo, HD
    MEDICAL PHYSICS, 2002, 29 (05) : 857 - 868
  • [3] A FORMULATION FOR HIGH-ENERGY PHOTON AND ELECTRON-BEAM DOSIMETRY
    SHIRAGAI, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1991, 36 (05): : 633 - 642
  • [4] A diamond detector in the dosimetry of high-energy electron and photon beams
    Laub, WU
    Kaulich, TW
    Nüsslin, F
    PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09): : 2183 - 2192
  • [5] SWISS RECOMMENDATIONS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    GARAVAGLIA, G
    ANDRE, L
    ARX, AV
    CORDT, I
    IONESCU, F
    VALLEY, JF
    MEDICAL PHYSICS, 1986, 13 (04) : 575 - 575
  • [6] NEW PROTOCOLS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON AND ELECTRON-BEAMS
    DUTREIX, A
    MIJNHEER, B
    SVENSSON, H
    RADIOTHERAPY AND ONCOLOGY, 1985, 4 (04) : 289 - 290
  • [7] Quantification of mean energy and photon contamination for accurate dosimetry of high-energy electron beams
    Sorcini, BB
    Hyodynmaa, S
    Brahme, A
    PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (10): : 1849 - 1873
  • [8] HIGH-ENERGY PHOTON DOSIMETRY IN FINITE ABSORBERS
    STAUBER, MC
    BRANDT, W
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1974, 19 (03): : 270 - 270
  • [9] Influence of electron contamination on in vivo surface dosimetry for high-energy photon beams
    Sjogren, R