DYNAMIC GD-DTPA ENHANCED MRI MEASUREMENT OF TISSUE CELL-VOLUME FRACTION

被引:90
|
作者
DONAHUE, KM
WEISSKOFF, RM
PARMELEE, DJ
CALLAHAN, RJ
WILKINSON, RA
MANDEVILLE, JB
ROSEN, BR
机构
[1] MASSACHUSETTS GEN HOSP, DEPT RADIOL, DIV NUCL MED, BOSTON, MA 02129 USA
[2] HARVARD UNIV, SCH MED, BOSTON, MA USA
[3] METASYN INC, CAMBRIDGE, MA USA
关键词
CELL FRACTION; GD-DTPA; PROTON EXCHANGE;
D O I
10.1002/mrm.1910340320
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A new technique for measuring tissue cellular volume fraction, based on an improved modeling of the dynamic distribution of Gd-DTPA and the effect of proton exchange, is described, This technique uses peak T-1 enhancement and blood Gd-DTPA concentration to compute tissue cellular volume fraction, The feasibility of this technique is demonstrated with computer simulations that explore the limits of the simplifying assumptions (small vascular space, slow vascular-extravascular proton exchange), and by direct comparison of MR and radionuclide cell fraction measurements made in muscle, liver, and tumor tissue in a rat model, The computer simulations demonstrate that with slow to intermediate vascular proton exchange and vascular fractions less than 10% the error in our cell fraction measurements typically remains less than 10%, Consistent with this prediction, a direct comparison between MR and radionuclide measurements of cell fraction demonstrates mean percent differences of less than 10%: 1.9% in muscle (n = 4); 9% in liver (n = 1) and 9.5% in tumor (n = 4), Similarly, for all rats studied, the MR-measured cell fractions (muscle (0.92 +/- 0.04, n = 20); liver (0.76 +/- 0.11, n = 9); whole tumor (0.69 +/- 0.15, n = 22)) agree with the cell fraction values reported in the literature, In general, the authors' results demonstrate the feasibility of a simple method for measuring tissue cell fraction that is robust across a broad range of vascular volume, flow, and exchange conditions, Consequently, this method may prove to be an important means for evaluating the response of tumors to therapy, Key words: Cell fraction; Gd-DTPA; proton exchange.
引用
收藏
页码:423 / 432
页数:10
相关论文
共 50 条
  • [31] MRI OF THORACIC MASSES - POTENTIAL USE OF GD-DTPA
    NAGELE, M
    HAHN, D
    SEELOS, K
    LISSNER, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 149 (01): : 69 - 75
  • [32] 肌骨系统Gd-DTPA MRI增强检查
    Beltran J
    陈彦仿
    国外医学(临床放射学分册) , 1992, (03) : 156 - 159
  • [33] SYNERGISTIC ENHANCEMENT OF MRI WITH GD-DTPA AND MAGNETIZATION TRANSFER
    TANTTU, JI
    SEPPONEN, RE
    LIPTON, MJ
    KUUSELA, T
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1992, 16 (01) : 19 - 24
  • [34] Atherosclerotic plaque detection by contrast-enhanced MRI: Gadofluorine vs Gd-DTPA
    Sirol, M
    Aguinaldo, JG
    Frias, JC
    Misselwitz, B
    Weinmann, HJ
    Ag, S
    Toussaint, JF
    Pompidou, G
    Fayad, ZA
    CIRCULATION, 2004, 110 (17) : 686 - 686
  • [35] The evaluation of subendomyocardial damage by Gd-DTPA enhanced MRI in patients with aortic valve stenosis
    Ochiai, K
    Shimada, T
    Ishibashi, Y
    Sano, K
    Murakami, Y
    Tahara, H
    Kitamura, J
    Kawamitsu, H
    Sugimura, K
    CIRCULATION, 1997, 96 (08) : 2882 - 2882
  • [36] GD-DTPA ENHANCED MRI OF HERPES-SIMPLEX ENCEPHALITIS - A CASE-REPORT
    SWITZER, P
    GOMORI, JM
    ELIASHIV, S
    CLINICAL IMAGING, 1991, 15 (02) : 121 - 124
  • [37] MEASUREMENT OF THE EXTRACTION EFFICIENCY AND DISTRIBUTION VOLUME FOR GD-DTPA IN NORMAL AND DISEASED CANINE MYOCARDIUM
    TONG, CY
    PRATO, FS
    WISENBERG, G
    LEE, TY
    CARROLL, E
    SANDLER, D
    WILLS, J
    DROST, D
    MAGNETIC RESONANCE IN MEDICINE, 1993, 30 (03) : 337 - 346
  • [38] Imaging Features of Hepatocellular Carcinoma Quantitative and Qualitative Comparison Between MRI-Enhanced With Gd-EOB-DTPA and Gd-DTPA
    Son, Jinwoo
    Hwang, Shin Hye
    Park, Sumi
    Han, Kyunghwa
    Chung, Yong Eun
    Choi, Jin-young
    Kim, Myeong-jin
    Park, Mi-Suk
    INVESTIGATIVE RADIOLOGY, 2019, 54 (08) : 494 - 499
  • [39] DYNAMIC STUDY OF THE PITUITARY WITH A HALF DOSE OF GD-DTPA
    KAWAMURA, Y
    SZE, G
    RADIOLOGY, 1992, 185 : 327 - 327
  • [40] Simultaneous quantitative cerebral perfusion and Gd-DTPA extravasation measurement with dual-echo dynamic susceptibility contrast MRI
    Vonken, EJPA
    van Osch, MJP
    Bakker, CJG
    Viergever, MA
    MAGNETIC RESONANCE IN MEDICINE, 2000, 43 (06) : 820 - 827