Axial length measurement techniques in pediatric eyes with cataract

被引:28
|
作者
Wilson, M. Edward [1 ]
Trivedi, Rupal H. [1 ]
机构
[1] Med Univ South Carolina, Miles Ctr Pediat Ophthalmol, Storm Eye Inst, Dept Ophthalmol, Charleston, SC USA
关键词
Immersion; Biometry; Prediction error; IOL power calculation;
D O I
10.1016/j.sjopt.2011.11.002
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Globe axial length (AL) in children is commonly measured using either contact or immersion technique. Office measurement of AL can be difficult in young children and infants and must often be done under anesthesia in an eye that is unable to cooperate with precise fixation and centration. Contact A-scan measurements yield shorter AL, on average, than immersion A-scan measurements in pediatric eyes. This difference is mainly the result of the anterior chamber depth rather than the lens thickness value. During intraocular lens power calculation, if globe axial length is measured by the contact technique, it will result in the use of an average 1-D stronger IOL power than is actually required. This can lead to induced myopia in the postoperative refraction. In our studied patients, there was a significant difference in prediction error between contact A-scan biometry and immersion A-scan biometry. The immersion A-scan technique is recommended for pediatric IOL power calculation. We also provide a review of biometry in pediatric eyes. The overall mean AL of pediatric cataractous eyes is significantly different than the mean AL of non cataractous eyes. More importantly, the standard deviation is higher in eyes with cataract than in those without. Three phases of eye growth in children have been documented: A rapid, postnatal phase from birth to 6 months of age, followed by a slower, infantile phase from 6 to 18 months of age, and finally a slow, juvenile phase from 18 months forward. In our study, girls had shorter ALs than boys and African-American subjects had longer ALs than Caucasians. Eyes with unilateral cataract had shorter ALs than eyes with bilateral cataract during the earlier years, but had longer ALs during later childhood.
引用
收藏
页码:13 / 17
页数:5
相关论文
共 50 条
  • [41] ECHOGRAPHIC AXIAL LENGTH MEASUREMENTS IN PSEUDOPHAKIC EYES
    ARTARIA, LG
    FREUDIGER, H
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1984, 184 (05) : 406 - 409
  • [42] Diurnal axial length fluctuations in human eyes
    Stone, RA
    Quinn, GE
    Francis, EL
    Ying, GS
    Flitcroft, DI
    Parekh, P
    Brown, J
    Orlow, J
    Schmid, G
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (01) : 63 - 70
  • [43] Psychophysical estimation of axial length in myopic eyes
    Potter, JA
    Strang, NC
    Barrett, BT
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U466 - U466
  • [44] Assessment of Axial Length Measurements in Mouse Eyes
    Park, Han Na
    Qazi, Yureeda
    Tan, Christopher
    Jabbar, Seema B.
    Cao, Yang
    Schmid, Gregor
    Pardue, Machelle T.
    OPTOMETRY AND VISION SCIENCE, 2012, 89 (03) : 296 - 303
  • [45] Axial length changes in healthy adult eyes
    Rozema, Jos J.
    Dhubhghaill, Sorcha Ni
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2019, 60 (09)
  • [46] Axial Length in Eyes with Macular Hole Reply
    Zeng, Jing
    Ding, Xiaoyan
    OPHTHALMOLOGY, 2013, 120 (09) : E67 - E68
  • [47] Influence of axial length of normal eyes on PERG
    Hidajat, R
    McIay, J
    Burley, C
    Elder, M
    Morton, J
    Goode, D
    DOCUMENTA OPHTHALMOLOGICA, 2003, 107 (02) : 195 - 200
  • [48] COMPARISON OF CONTACT AND IMMERSION TECHNIQUES FOR AXIAL LENGTH MEASUREMENT AND IMPLANT POWER CALCULATION
    SCHELENZ, J
    KAMMANN, J
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 1989, 15 (04): : 425 - 428
  • [49] Comparison of A-scan and MRI for the measurement of axial length in silicone oil-filled eyes
    Bencic, G.
    Vatavuk, Z.
    Marotti, M.
    Loncar, V. L.
    Petric, I.
    Andrijevic-Derk, B.
    Skunca, J.
    Mandic, Z.
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2009, 93 (04) : 502 - 505
  • [50] Axial length measurement in silicone oil-filled eyes using laser Doppler interferometry
    Chae, JB
    Park, HR
    Yoon, YH
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2004, 24 (04): : 655 - 657