FLUID-DYNAMICS OF VENOUS VALVE CLOSURE

被引:22
|
作者
QUI, YC
QUIJANO, RC
WANG, SK
HWANG, NHC
机构
[1] UNIV MIAMI,DEPT BIOMED ENGN,CORAL GABLES,FL 33124
[2] BAXTER EDWARDS CVS DIV,IRVINE,CA
关键词
VENOUS PROSTHESIS; REFLUX FLOW AT VALVE CLOSURE; OPENING AREA; CLOSED P-Q LOOP; LASER DOPPLER ANEMOMETER;
D O I
10.1007/BF02584474
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In vitro experiment was performed on a stented bovine jugular vein valve (VV, 14 mm I.D. x 2 cm long) and a stentless bovine jugular vein valve conduit (10 mm I.D. x 6 cm long) in a hydraulic flow loop with a downstream oscillatory pressure source to mimic respiratory changes. Simultaneous measurements were made on the valve opening area, conduit and sinus diameter changes using a specially designed laser optic system. Visualization of flow fields both proximal and distal to the venous valve, and the valve opening area were simultaneously recorded by using two video cameras. Laser Doppler anemometer surveys were made at three cross sections: the valve inlet, the valve exist, and 2 cm downstream of the venous valve to quantity flow reflux at valve closure. The experiment confirmed that the VV is a pressure-operated rather than a flow-driven device and that little or no reflux is needed to close the valve completely, The experiment further demonstrated that the VV sinus expands rapidly against back pressure, a critical character to consider in venous prosthesis design.
引用
下载
收藏
页码:750 / 759
页数:10
相关论文
共 50 条