THE ROLE OF XENON CT MEASUREMENTS OF CEREBRAL BLOOD-FLOW IN THE CLINICAL DETERMINATION OF BRAIN-DEATH

被引:0
|
作者
PISTOIA, F
JOHNSON, DW
DARBY, JM
HORTON, JA
APPLEGATE, LJ
YONAS, H
机构
[1] UNIV PITTSBURGH, PRESBYTERIAN UNIV HOSP,SCH MED,DEPT RADIOL, DIV NEURORADIOL, PITTSBURGH, PA 15213 USA
[2] UNIV PITTSBURGH, PRESBYTERIAN UNIV HOSP, SCH MED, DEPT ANESTHESIOL, PITTSBURGH, PA 15213 USA
[3] UNIV PITTSBURGH, PRESBYTERIAN UNIV HOSP, SCH MED, DEPT NEUROSURG, PITTSBURGH, PA 15213 USA
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The demonstration of absent blood flow to the brain is often used as a confirmatory test of brain death. Traditionally, cerebral angiography and dynamic radionuclide brain scanning have been used for this purpose. Recently, xenon CT cerebral blood flow techniques have been developed and applied to a wide variety of clinical problems, including the confirmation of brain death. We report our experience with xenon CT studies performed over a 7-year period (1983-1989) in 30 patients with brain injuries. These patients met clinical criteria for brain death within 24 hr of the study. Twenty patients had average global flow values of less than 5 ml/100 ml/min. Seven patients demonstrated mixed flow patterns, whereby large areas of brain showed flow values of < 5 ml/100 ml/min and residual pockets of flow greater than 5 ml/100/ml/min. Globally symmetric normal to hyperemic flows were seen in three patients. Our study suggests that demonstration of average global flows of < 5/ml/100 ml/min is confirmatory of brain death. Demonstration of persistent flow to the entire brain or regions of the brain is not diagnostic of brain death but also does not exclude such an outcome in patients with severe brain injuries. Xenon-derived flow information may be clinically useful in determining the patient's prognosis and in counseling the patient's family.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [41] XENON ENHANCED DYNAMIC CT - MULTILEVEL CEREBRAL BLOOD-FLOW STUDIES
    WOLFSON, SK
    YONAS, H
    GUR, D
    SHABASON, L
    LATCHAW, RE
    GOOD, W
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1982, 3 (01) : 95 - 95
  • [42] XENON CT CEREBRAL BLOOD-FLOW STUDIES IN THE ASSESSMENT OF LOCATION, TIMING, AND SEVERITY OF CLINICAL VASOSPASM
    FUKUI, MB
    JOHNSON, DW
    YONAS, H
    SEKHAR, L
    LATCHAW, RE
    GUR, D
    PENTHENY, S
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1988, 9 (05) : 1009 - 1010
  • [43] XENON ENHANCED CT FOR ANALYSIS OF CEREBRAL INTEGRITY, PERFUSION, AND BLOOD-FLOW
    DRAYER, BP
    WOLFSON, SK
    REINMUTH, OM
    DUJOVNY, M
    BOEHNKE, M
    COOK, EE
    STROKE, 1978, 9 (02) : 123 - 130
  • [44] NEW CEREBRAL BLOOD-FLOW TECHNIQUE XENON ENHANCED CT SCANNING
    DRAYER, BP
    WOLFSON, SK
    REINMUTH, OM
    DUJOVNY, M
    BOEHNKE, M
    COOK, EE
    STROKE, 1978, 9 (01) : 103 - 103
  • [45] REGIONAL CEREBRAL BLOOD-FLOW IN EPILEPSY STUDIED WITH XENON ENHANCED CT
    DUNCAN, R
    PATTERSON, J
    JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1988, 51 (10): : 1366 - 1367
  • [46] SIMULATION STUDY OF CEREBRAL BLOOD-FLOW MEASUREMENTS IN XENON-CT - EVALUATION OF WASHIN WASHOUT PROCEDURES
    POLACIN, A
    KALENDER, WA
    EIDLOTH, H
    MEDICAL PHYSICS, 1991, 18 (05) : 1025 - 1031
  • [47] CEREBRAL BLOOD-CIRCULATION AND BRAIN-DEATH
    KEVORKIAN, J
    WESTERN JOURNAL OF MEDICINE, 1988, 149 (01): : 94 - 94
  • [48] DETERMINATION OF CEREBRAL BLOOD-FLOW WITH THE EMI CT SCANNER
    KOEZE, TH
    WYLIE, IG
    BRITISH JOURNAL OF RADIOLOGY, 1980, 53 (629): : 410 - 415
  • [49] CEREBRAL BLOOD-FLOW AND BRAIN METABOLISM AS INDICATORS OF CEREBRAL DEATH - REVIEW
    SMITH, AJK
    WALKER, AE
    JOHNS HOPKINS MEDICAL JOURNAL, 1973, 133 (02): : 107 - 119
  • [50] STABLE XENON VERSUS RADIOLABELED MICROSPHERE CEREBRAL BLOOD-FLOW MEASUREMENTS IN BABOONS
    DEWITT, DS
    FATOUROS, PP
    WIST, AO
    STEWART, LM
    KONTOS, HA
    HALL, JA
    KISHORE, PRS
    KEENAN, RL
    MARMAROU, A
    STROKE, 1989, 20 (12) : 1716 - 1723