THE ROLE OF XENON CT MEASUREMENTS OF CEREBRAL BLOOD-FLOW IN THE CLINICAL DETERMINATION OF BRAIN-DEATH

被引:0
|
作者
PISTOIA, F
JOHNSON, DW
DARBY, JM
HORTON, JA
APPLEGATE, LJ
YONAS, H
机构
[1] UNIV PITTSBURGH, PRESBYTERIAN UNIV HOSP,SCH MED,DEPT RADIOL, DIV NEURORADIOL, PITTSBURGH, PA 15213 USA
[2] UNIV PITTSBURGH, PRESBYTERIAN UNIV HOSP, SCH MED, DEPT ANESTHESIOL, PITTSBURGH, PA 15213 USA
[3] UNIV PITTSBURGH, PRESBYTERIAN UNIV HOSP, SCH MED, DEPT NEUROSURG, PITTSBURGH, PA 15213 USA
关键词
D O I
暂无
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
The demonstration of absent blood flow to the brain is often used as a confirmatory test of brain death. Traditionally, cerebral angiography and dynamic radionuclide brain scanning have been used for this purpose. Recently, xenon CT cerebral blood flow techniques have been developed and applied to a wide variety of clinical problems, including the confirmation of brain death. We report our experience with xenon CT studies performed over a 7-year period (1983-1989) in 30 patients with brain injuries. These patients met clinical criteria for brain death within 24 hr of the study. Twenty patients had average global flow values of less than 5 ml/100 ml/min. Seven patients demonstrated mixed flow patterns, whereby large areas of brain showed flow values of < 5 ml/100 ml/min and residual pockets of flow greater than 5 ml/100/ml/min. Globally symmetric normal to hyperemic flows were seen in three patients. Our study suggests that demonstration of average global flows of < 5/ml/100 ml/min is confirmatory of brain death. Demonstration of persistent flow to the entire brain or regions of the brain is not diagnostic of brain death but also does not exclude such an outcome in patients with severe brain injuries. Xenon-derived flow information may be clinically useful in determining the patient's prognosis and in counseling the patient's family.
引用
收藏
页码:97 / 103
页数:7
相关论文
共 50 条
  • [1] BRAIN-DEATH AND CEREBRAL BLOOD-FLOW
    ROINE, RO
    LAUNES, J
    LINDROTH, L
    NIKKINEN, P
    LANCET, 1987, 1 (8523): : 46 - 47
  • [2] XENON COMPUTED-TOMOGRAPHY MEASURING CEREBRAL BLOOD-FLOW IN THE DETERMINATION OF BRAIN-DEATH IN CHILDREN
    ASHWAL, S
    SCHNEIDER, S
    THOMPSON, J
    ANNALS OF NEUROLOGY, 1989, 25 (06) : 539 - 546
  • [3] BRAIN-DEATH IN THE NEWBORN - CLINICAL, ELECTROENCEPHALOGRAPHIC, AND CEREBRAL BLOOD-FLOW DETERMINATIONS
    ASHWAL, S
    SCHNEIDER, S
    ANNALS OF NEUROLOGY, 1988, 24 (02) : 337 - 337
  • [4] CEREBRAL BLOOD-FLOW CHANGES USING DOPPLER ULTRASOUND IN DETERMINATION OF BRAIN-DEATH
    JALILI, M
    CRADE, M
    DAVIS, A
    CLINICAL RESEARCH, 1992, 40 (01): : A107 - A107
  • [5] RADIONUCLIDE CEREBRAL BLOOD-FLOW IMAGING AS AN ADJUNCT IN THE DETERMINATION OF BRAIN-DEATH IN CHILDREN
    HOLZMAN, BH
    CURLESS, RG
    SFAKIANAKIS, GN
    AJMONEMARSAN, C
    MONTES, JE
    CRITICAL CARE MEDICINE, 1982, 10 (03) : 215 - 215
  • [6] XENON CT SCANNING FOR MEASUREMENTS OF CEREBRAL BLOOD-FLOW
    GILLER, CA
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (05) : 1024 - 1025
  • [7] XENON CT SCANNING FOR MEASUREMENTS OF CEREBRAL BLOOD-FLOW - REPLY
    GOOD, WF
    GUR, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (05) : 1025 - 1025
  • [8] REVERSAL OF DIASTOLIC CEREBRAL BLOOD-FLOW IN INFANTS WITHOUT BRAIN-DEATH
    CHIU, NC
    SHEN, EY
    LEE, BS
    PEDIATRIC NEUROLOGY, 1994, 11 (04) : 337 - 340
  • [9] CLINICAL CEREBRAL BLOOD-FLOW MEASUREMENT WITH INHALED XENON AND CT
    HAUGHTON, V
    DONEGAN, J
    WALSH, P
    SYVERTSEN, A
    WILLIAMS, A
    WILSON, C
    CUSICK, J
    SCHMIDT, J
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1980, 134 (02) : 281 - 283
  • [10] XENON-ENHANCED CT OF THE BRAIN - EFFECT OF FLOW ACTIVATION ON DERIVED CEREBRAL BLOOD-FLOW MEASUREMENTS
    GOOD, WF
    GUR, D
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (01) : 83 - 85