MEASUREMENT OF FORCE APPLIED DURING MAMMOGRAPHY

被引:40
|
作者
SULLIVAN, DC
BEAM, CA
GOODMAN, SM
WATT, DL
机构
[1] Department of Radiology, Duke University Medical Center, Durham, NC 27710, Trent Dr
关键词
BREAST RADIOGRAPHY; TECHNOLOGY;
D O I
10.1148/radiology.181.2.1924771
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The discomfort that patients experience during mammography is probably related to a variety of factors, one of which might be the amount of compression used. The authors measured the amount of force applied to the breasts during mammography and the resulting breast thickness in 560 women and correlated these measurements with the patient's subjective impression of the examination. The amount of force applied ranged from 49 to 186.2 N (median, 122.5 N). Breast thickness ranged from 10 to 88 mm (median, 46.5 mm). Forty-seven women (8%) rated the examination as painful (ie, mammography was either "very uncomfortable" or "intolerable"). Logistic regression analysis revealed a highly significant relationship between probability of a painful response and ratio of force to thickness (P = .007). Current guidelines suggest that maximum available force be at least 160 N but not more than 200 N. However, because increasing force is associated with increasing likelihood of pain, technologists should be aware that these recommended maximum limits are not intended to be used routinely for all women. In this study, high-quality mammograms were obtained in a majority of women with forces less than the maximum available level.
引用
收藏
页码:355 / 357
页数:3
相关论文
共 50 条
  • [1] Measurement of applied force and deflection in the javelin throw
    Maeda, M
    Shamoto, E
    Moriwaki, T
    Nomura, H
    JOURNAL OF APPLIED BIOMECHANICS, 1999, 15 (04) : 429 - 442
  • [2] FORCE APPLIED DURING TRACHEAL INTUBATION
    BISHOP, MJ
    HARRINGTON, RM
    TENCER, AF
    ANESTHESIA AND ANALGESIA, 1992, 74 (03): : 411 - 414
  • [3] Measurement of force applied by infant tongue to the nipple during sucking and investigation of the mechanism of tongue movement
    Nishi, Eri
    Nagamatsu, Yuiko
    Niikawa, Takuya
    2016 38TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2016, : 2042 - 2045
  • [4] AN INSTRUMENT FOR MONITORING THE FORCE APPLIED BY BREAST COMPRESSION DEVICES ON MAMMOGRAPHY X-RAY SETS
    FAULKNER, K
    CHAMBERS, IR
    HEDLEY, P
    THOMPSON, SR
    CLINICAL PHYSICS AND PHYSIOLOGICAL MEASUREMENT, 1989, 10 (02): : 177 - 180
  • [5] Changing Where Force is Applied Influences Force Parameters During Ergometer Rowing
    Becker, James
    Jackson, Renae
    Nakajima, Mimi
    Wu, Will
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2016, 48 (05): : 621 - 621
  • [6] Mammography compression force readings
    Ma, Wang Kei
    Hogg, Peter
    Kelly, Judith
    Millington, Sara
    RADIOGRAPHY, 2013, 19 (03) : 280 - 280
  • [7] Changes in applied force to a touchpad during pointing tasks
    Akamatsu, M
    MacKenzie, IS
    INTERNATIONAL JOURNAL OF INDUSTRIAL ERGONOMICS, 2002, 29 (03) : 171 - 182
  • [8] Applied force during vitreoretinal microsurgery with handheld instruments
    Jagtap, AD
    Riviere, CN
    PROCEEDINGS OF THE 26TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2004, 26 : 2771 - 2773
  • [9] Force applied to a grab bar during bathtub transfers
    Guay, Manon
    Vinet, Myriam
    Bombardier, Anne-Marie
    Hamel, Mathieu
    Sveistrup, Heidi
    Demers, Louise
    Smeesters, Cecile
    CLINICAL BIOMECHANICS, 2020, 80 (80)
  • [10] Is Individualizing Breast Compression during Mammography useful? - Investigations of Pain Indications during Mammography Relating to Compression Force and Surface Area of the Compressed Breast
    Feder, Katarzyna
    Grunert, Jens-Holger
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (01): : 39 - 48