REPRODUCIBILITY OF MEASUREMENTS OF THUMB ABDUCTION

被引:3
|
作者
Itoh, Shozo [1 ]
Miura, Toshiki [1 ]
Oka, Hiroyuki [2 ]
Nakagawa, Takumi [1 ]
Nakamura, Kozo [1 ]
机构
[1] Univ Tokyo, Fac Med, Dept Orthopaed Surg, Tokyo 1138655, Japan
[2] Univ Tokyo, Fac Med, 22nd Century Med Ctr, Tokyo 1138655, Japan
来源
关键词
Thumb; Abduction; Reproducibility; Intraclass Correlation Coefficient; Measurement;
D O I
10.1142/S0218810410004461
中图分类号
R61 [外科手术学];
学科分类号
摘要
The reproducibilities of various measurements of thumb abduction were compared. Two independent observers measured the thumb abduction in 30 volunteers by the following four methods: distance between the thumb tip and the flexion crease of the index finger proximal interphalangeal joint; distance between the flexion crease of the thumb interphalangeal joint and the proximal palmar crease; angle between the thumb and index metacarpals; and angle between the thumb and index proximal phalanxes. Measurements were repeated in three weeks and their reproducibility was assessed by the intraclass correlation coefficient (ICC). Intra-observer reproducibilities by distances were high with ICCs between 0.74 and 0.89, compared with those by angles with ICCs between 0.28 and 0.71. Inter-observer reproducibilities by distances were also high (ICCs = 0.79 and 0.81) compared with those by angles (ICCs = 0.28 and 0.42). Assessment of thumb abduction based on distance in the first web is recommended in terms of reproducibility.
引用
收藏
页码:7 / 10
页数:4
相关论文
共 50 条
  • [31] A torque-controlled device to measure passive abduction of the thumb carpometacarpal joint
    Harvey, Lisa
    de Jong, Inge
    Goehl, Gerlinde
    Armstrong, Belinda
    Allaous, Jeanine
    JOURNAL OF HAND THERAPY, 2006, 19 (04) : 403 - 408
  • [32] Electrophysiological parameters in carpal tunnel syndrome (about the disturbance of palmer abduction of thumb)
    Maki, S
    Taniguchi, Y
    HAND SURGERY IN THE NEXT MILLENNIUM, 1999, : 23 - 26
  • [33] Measurement of thumb abduction strength: Normative data and a comparison with grip and pinch strength
    Boatright, JR
    Kiebzak, GM
    ONeil, DM
    Peindl, RD
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (05): : 843 - 848
  • [34] THE REPRODUCIBILITY OF FOAM MEASUREMENTS
    WEYH, H
    MONATSSCHRIFT FUR BRAUWISSENSCHAFT, 1988, 41 (09): : 353 - 360
  • [35] The Reproducibility of Flare Measurements
    Okka, M.
    Adam, M.
    Ozturk, B. T.
    Bozkurt, B.
    Kerimoglu, H.
    Pekel, H.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (13)
  • [36] REPRODUCIBILITY OF ELECTROMIGRATION MEASUREMENTS
    SCHAFFT, HA
    STATON, TC
    MANDEL, J
    SHOTT, JD
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1987, 34 (03) : 673 - 681
  • [37] REPRODUCIBILITY OF MTF MEASUREMENTS
    MARCHANT, AC
    IRONSIDE, EA
    ATTRYDE, JF
    WILLIAMS, TL
    OPTICA ACTA, 1975, 22 (04): : 249 - 264
  • [38] Reproducibility of a 3-dimensional gyroscope in measuring shoulder anteflexion and abduction
    Penning, Ludo I. F.
    Guldemond, Nick A.
    de Bie, Rob A.
    Walenkamp, Geert H. I. M.
    BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [39] Reproducibility of a 3-dimensional gyroscope in measuring shoulder anteflexion and abduction
    Ludo I F Penning
    Nick A Guldemond
    Rob A de Bie
    Geert H I M Walenkamp
    BMC Musculoskeletal Disorders, 13
  • [40] A Comparison of the Reliability of Make Versus Break Testing in Measuring Palmar Abduction Strength of the Thumb
    Lim, J. X.
    Toh, R. X.
    Chook, S. K. H.
    Sebastin, S. J.
    Karjalainen, T.
    JOURNAL OF HAND AND MICROSURGERY, 2014, 6 (01) : 8 - 12