Radiographic review of limb-length discrepancy after total hip arthroplasty

被引:0
|
作者
Winemaker, Mitchell [1 ,2 ,3 ]
Lopez, Carlos [1 ]
Staibano, Anthony [1 ]
Petruccelli, Danielle [2 ,3 ]
de Beer, Justin [1 ,2 ,3 ]
机构
[1] McMaster Univ, Hamilton, ON, Canada
[2] Hamilton Arthroplasty Grp, Hamilton, ON, Canada
[3] Hamilton Hlth Sci Henderson Hosp, Hamilton, ON, Canada
来源
CURRENT ORTHOPAEDIC PRACTICE | 2010年 / 21卷 / 05期
关键词
alignment; leg-length discrepancy; radiographic review; total hip arthroplasty;
D O I
10.1097/BCO.0b013e3181ebdf57
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background A clinical and radiographic review was undertaken to evaluate technical causes for limb-length discrepancy (LLD) after total hip arthroplasty and the resultant effect on function. We hypothesized that limb lengthening most commonly occurs as a result of low placement of the acetabular implant. Methods A sample of 116 primary total hip arthroplasties performed between 2005 and 2007 with complete 1-year postoperative clinical outcomes scores and appropriate radiographs available on the Picture Archiving and Communication System were identified from a prospective arthroplasty database. Significant limb lengthening was defined as lengthening of more than 8mm as compared with the contralateral limb postoperatively. Preoperative and 1-year postoperative anteroposterior bilateral hip radiographs were reviewed by two orthopaedic surgeons and one orthopaedic resident. Preoperative and postoperative LLD as well as the respective acetabular and femoral contribution to any postoperative LLD (if present) were measured. Results Nineteen of 116 (16.4%) patients had limb lengthening of more than 8mm, of which the majority were women (14 of 19, P = 0.015). Of those over-lengthened, the mean difference from preoperative to postoperative LLD was 1.3mm (SD 7.6mm). A mean of 6.2mm (SD 6.2mm) of lengthening was contributed by the femoral stem, and 5.3mm (SD 6.3mm) by low placement of the acetabular implant (P = 0.738). Lengthening and femoral placement of the stem (r = 0.489, P = 0.000), and lengthening and low cup placement (r = 0.596, P = 0.000) were significantly correlated. There was no correlation between LLD and Harris Hip or Oxford Score at 1-year postoperatively. Conclusions Limb lengthening results from a combination of low acetabular implant and high femoral stem placement but did not result in inferior outcomes in the current study.
引用
收藏
页码:504 / 507
页数:4
相关论文
共 50 条
  • [41] Scoliosis Caused by Limb-Length Discrepancy in Children
    Kobayashi, Kazuyoshi
    Ando, Kei
    Nakashima, Hiroaki
    Machino, Masaaki
    Morozumi, Masayoshi
    Kanbara, Shunsuke
    Ito, Sadayuki
    Inoue, Taro
    Yamaguchi, Hidetoshi
    Mishima, Kenichi
    Ishiguro, Naoki
    Imagama, Shiro
    [J]. ASIAN SPINE JOURNAL, 2020, 14 (06) : 801 - 807
  • [42] Effect of femoral offset and limb length discrepancy on hip joint muscle strength and gait trajectory after total hip arthroplasty
    Sato, Hironobu
    Maezawa, Katsuhiko
    Gomi, Motoshi
    Kajihara, Hajime
    Hayashi, Akito
    Maruyama, Yuichiro
    Nozawa, Masahiko
    Kaneko, Kazuo
    [J]. GAIT & POSTURE, 2020, 77 : 276 - 282
  • [43] Limb-Length Discrepancy as a Cause of Plantar Fasciitis
    Mahmood, Sadia
    Huffman, Lanie K.
    Harris, John G.
    [J]. JOURNAL OF THE AMERICAN PODIATRIC MEDICAL ASSOCIATION, 2010, 100 (06) : 452 - 455
  • [44] Does intraoperative fluoroscopy improve acetabular component positioning and limb-length discrepancy during direct anterior total hip arthroplasty? A meta-analysis
    Changjiao Sun
    Woo Guan Lee
    Qi Ma
    Xiaofei Zhang
    Zhe Zhao
    Xu Cai
    [J]. Journal of Orthopaedic Surgery and Research, 18
  • [45] Comparison of Limb-length Discrepancy After THA: With and Without Computer Navigation
    Licini, David J.
    Burnikel, David J.
    Meneghini, R. Michael
    Ochsner, John L.
    [J]. ORTHOPEDICS, 2013, 36 (05) : E543 - E547
  • [46] Leg Length Discrepancy in Primary Total Hip Arthroplasty
    Pyrko, Peter
    Zuckerman, Joseph
    [J]. BULLETIN OF THE HOSPITAL FOR JOINT DISEASES, 2016, 74 (01): : 82 - 87
  • [47] Does intraoperative fluoroscopy improve acetabular component positioning and limb-length discrepancy during direct anterior total hip arthroplasty? A meta-analysis
    Sun, Changjiao
    Lee, Woo Guan
    Ma, Qi
    Zhang, Xiaofei
    Zhao, Zhe
    Cai, Xu
    [J]. JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [48] LEG LENGTH DISCREPANCY IN TOTAL HIP-ARTHROPLASTY
    ABRAHAM, WD
    DIMON, JH
    [J]. ORTHOPEDIC CLINICS OF NORTH AMERICA, 1992, 23 (02) : 201 - 209
  • [49] Perioperative management of leg-length discrepancy in total hip arthroplasty: a review
    Gheewala, Rohan A.
    Young, Joseph R.
    Villacres Mori, Benjamin
    Lakra, Akshay
    DiCaprio, Matthew R.
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (08) : 5417 - 5423
  • [50] Perioperative management of leg-length discrepancy in total hip arthroplasty: a review
    Rohan A. Gheewala
    Joseph R. Young
    Benjamin Villacres Mori
    Akshay Lakra
    Matthew R. DiCaprio
    [J]. Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 5417 - 5423