Bone preserving techniques for explanting the well-fixed cemented acetabular component

被引:2
|
作者
Stevens, Jarrad [1 ]
Macpherson, Gavin [1 ]
Howie, Colin [1 ]
机构
[1] Royal Infirm Edinburgh NHS Trust, Dept Orthopaed & Trauma Surg, Edinburgh, Midlothian, Scotland
关键词
Cement; Hip arthroplasty; Explant; Well-fixed; Acetabular component;
D O I
10.1016/j.jor.2018.03.037
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Removal of a well-fixed, cemented acetabular component at the time of revision hip surgery can be complex. It is essential to remove the implant and cement mantle in a timely fashion while preserving bone stock and osseous integrity. The biomechanical properties of polymethylmethacrylate cement and polyethylene can be utilised to aid with the removal of well cemented implants which are often harder than the surrounding bone. While removal of loose components may be relatively straightforward, the challenge for the revision arthroplasty surgeon often involves the removal of well-fixed implants. Here, we present three established techniques for the removal of a well-fixed cemented acetabular component and one novel modification we have described before. Method: We collate and review four techniques for removing well-fixed cemented acetabular implants that utilise the different biomechanical properties of bone cement and polyethylene. These techniques are illustrated with a photographic series utilising saw bones. A step-by-step approach to our new technique is shown in photographs, both in the clinical setting and with a "Sawbone". This is accompanied by a clinical video that details the surgical technique in its entirety. Results: These techniques utilise different biomechanical principles to extract the acetabular component. Each technique has advantages and disadvantages. Our new technique is a simplification of a previously published extraction manoeuvre that utilises tensile force between cement and the implant to remove the polyethylene cup. This is a safe and reproducible technique in patients with a well-fixed cemented acetabular implant. Conclusion: Understanding the biomechanical properties of polymethylmethacrylate bone cement and polyethylene can aid in the safe removal of a well-fixed cemented acetabular component in revision hip surgery. The optimal technique for removal of a cemented acetabular component varies depending on a number of patient and implant factors. This summary of the available techniques will be of interest to revision arthroplasty surgeons.
引用
收藏
页码:500 / 505
页数:6
相关论文
共 50 条
  • [11] Results of Isolated Femoral Component Revision With Well-Fixed Acetabular Implant Retention
    Park, Kyung Soon
    Yoon, Taek Rim
    Song, Eun Kyoo
    Lee, Keun Bae
    [J]. JOURNAL OF ARTHROPLASTY, 2010, 25 (08): : 1188 - 1195
  • [12] Pearls: How to Remove a Ceramic Liner From a Well-fixed Acetabular Component
    Pitto, Rocco P.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2016, 474 (01) : 25 - 26
  • [13] Long-Term Outcomes of Constrained Liners Cemented into Retained, Well-Fixed Acetabular Components
    Brown, Timothy S.
    Tibbo, Meagan E.
    Arsoy, Diren
    Lewallen, David G.
    Hanssen, Arlen D.
    Trousdale, Robert T.
    Abdel, Matthew P.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2019, 101 (07): : 620 - 627
  • [14] Retention of a Well-Fixed Acetabular Component in the Setting of Massive Acetabular Osteolysis and Pelvic Discontinuity A Case Report
    Pekmezci, Murat
    Keeney, James
    Schutz, Amanda
    Clohisy, John C.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2009, 91A (09): : 2232 - 2237
  • [15] Using the Explant Acetabular Cup Removal System for removing a well-fixed resurfacing cementless acetabular component
    Bhutta, M. A.
    Gambhir, A.
    [J]. ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2009, 91 (04) : 344 - 344
  • [16] Revision of well-fixed cementless acetabular components for polyethylene failure
    Peters, CL
    Erickson, JA
    Dunn, HK
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (414) : 129 - 135
  • [17] Cementing an insert in a well-fixed tibial component
    Whiteside, Leo A.
    [J]. ORTHOPEDICS, 2008, 31 (09) : 950 - 951
  • [18] Migration of polyethylene debris along well-fixed cemented implants
    Massin, P
    Viguier, E
    Flautre, B
    Hardouin, P
    Astoin, E
    Duponchel, B
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2004, 68B (02) : 140 - 148
  • [19] Removal of well-fixed, cementless, acetabular components in revision hip arthroplasty
    Mitchell, PA
    Masri, BA
    Garbuz, DS
    Greidanus, NV
    Wilson, D
    Duncan, CP
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2003, 85B (07): : 949 - 952
  • [20] The fate of well fixed cemented femoral components left in place at the time of revision of the acetabular component
    Peters, CL
    Kull, L
    Jacobs, JJ
    Rosenberg, AG
    Galante, JO
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1997, 79A (05): : 701 - 706