EVALUATION OF MENISCAL TEARS - FAST SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO MAGNETIC-RESONANCE-IMAGING

被引:23
|
作者
ANDERSON, MW
RAGHAVAN, N
SEIDENWURM, DJ
GREENSPAN, A
DRAKE, C
机构
[1] RADIOL ASSOCIATES SACRAMENTO,SACRAMENTO,CA
[2] UNIV CALIF DAVIS,SCH MED,DEPT STAT,SACRAMENTO,CA
关键词
MAGNETIC RESONANCE IMAGING; KNEE; MENISCI; FAST SPIN ECHO;
D O I
10.1016/S1076-6332(05)80166-7
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. We compared the performance of fast spin-echo (FSE) with conventional spin-echo (CSE) magnetic resonance (MR) imaging sequences in the detection of meniscal tears. Methods. Seventy-three patients underwent MR examination of the knee for suspected internal derangement. Each patient was scanned with a CSE sequence and one of two FSE sequences. The primary difference between the two FSE sequences consisted of the echo train length (ETL). Thirty-seven patients (group 1) were scanned with the FSE I sequence (ETL = 8), and 36 patients (group 2) were scanned with the FSE II sequence (ETL = 4). Menisci were graded as torn or not torn on the basis of their MR appearance, The sequences were compared with each other and with the surgical findings in 31 patients who underwent arthroscopy. Results. In group 1, there was a significant discrepancy between the CSE and FSE I techniques (p = .006). The FSE I sequence detected only 11 of 19 surgically proven torn menisci as opposed to 18 of 19 detected with the CSE sequence. The FSE II sequence performed significantly better in group 2, with an accuracy equal to that of the CSE sequence. Conclusion. FSE sequences are extremely technique dependent with regard to detecting meniscal tears and should not replace CSE sequences in this setting until further studies are performed to optimize the technique.
引用
收藏
页码:209 / 214
页数:6
相关论文
共 50 条
  • [31] Contrast enhancement of intracranial lesions: conventional T1-weighted spin-echo versus fast spin-echo MR imaging techniques
    Sugahara, T
    Korogi, Y
    Ge, YL
    Shigematsu, Y
    Liang, LX
    Yoshizumi, K
    Kitajima, M
    Takahashi, M
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1999, 20 (08) : 1554 - 1559
  • [32] MRI of the intracerebral lesions at 0.5 tesla: Comparison of fast spin-echo and conventional spin-echo sequences
    Incesu, L
    Gunes, M
    Akan, H
    Selcuk, MB
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1996, 20 (02) : 105 - 113
  • [33] SPIN-ECHO ANATOMY OF THE LARYNX WITH MAGNETIC-RESONANCE-IMAGING AT 1.5-T
    BERTOLANI, M
    BUONAURA, PC
    SPINA, V
    DALIMONTE, P
    ROMANI, U
    CRISCUOLO, M
    ROMAGNOLI, R
    JOURNAL DE RADIOLOGIE, 1993, 74 (01): : 1 - 12
  • [34] MAGNETIC-RESONANCE-IMAGING OF KNEE MENISCI - COMPARISON OF SPIN-ECHO PULSE SEQUENCES
    EVANCHO, AM
    FAJMAN, WA
    STILES, RG
    BRUNNER, MC
    PETERSON, J
    FLEMING, L
    INVESTIGATIVE RADIOLOGY, 1990, 25 (11) : 1224 - 1227
  • [35] A comparison of conventional spin-echo and turbo spin-echo imaging of soft tissues adjacent to orthopedic hardware
    Eustace, S
    Jara, H
    Goldberg, R
    Fenlon, H
    Mason, M
    Melhem, ER
    Yucel, EK
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 170 (02) : 455 - 458
  • [36] T2-WEIGHTED MR-IMAGING OF THE ABDOMEN - FAST SPIN-ECHO VS CONVENTIONAL SPIN-ECHO SEQUENCES
    CATASCA, JV
    MIROWITZ, SA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 162 (01) : 61 - 67
  • [37] INTRACEREBRAL LESION CONTRAST WITH SPIN-ECHO AND FAST SPIN-ECHO PULSE SEQUENCES
    NORBASH, AM
    GLOVER, GH
    ENZMANN, DR
    RADIOLOGY, 1992, 185 (03) : 661 - 665
  • [38] Isotropic diffusion weighting in radial fast spin-echo magnetic resonance imaging
    Sarlls, JE
    Newbould, RD
    Altbach, MI
    Gmitro, AF
    Seeger, J
    Trouard, TP
    MAGNETIC RESONANCE IN MEDICINE, 2005, 53 (06) : 1347 - 1354
  • [39] Fast spin-echo for multiple mouse magnetic resonance phenotyping
    Nieman, BJ
    Bock, NA
    Bishop, J
    Sled, JG
    Chen, XJ
    Henkelman, RM
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (03) : 532 - 537
  • [40] MOTION ARTIFACTS IN FAST SPIN-ECHO IMAGING
    MADORE, B
    HENKELMAN, RM
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1994, 4 (04): : 577 - 584