PERCUTANEOUS VS TRANSCUTANEOUS TRANSDUCERS FOR HEARING BY DIRECT BONE CONDUCTION

被引:29
|
作者
HAKANSSON, B [1 ]
TJELLSTROM, A [1 ]
CARLSSON, P [1 ]
机构
[1] SAHLGRENS UNIV HOSP,DEPT EAR NOSE & THROAT,S-41345 GOTHENBURG,SWEDEN
关键词
D O I
10.1177/019459989010200407
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
There is a substantial need for improvement of the hearing situation for patients with chronic middle ear or ear canal disorders. To improve hearing for these patients, two different bone conduction hearing systems have been developed. The Nobelpharma Auditory System HC 200—the bone-anchored hearing aid we present here—uses a percutaneous transducer; whereas the Audiant device, developed by Dr. Jack Hough, uses a transcutaneous transducer. In percutaneous transmission, the transducer is directly coupled to the bone by means of a permanent skin penetration, whereas in transcutaneous transmission one part of the transducer is implanted and the other part is kept outside the intact skin and soft tissue. Comprehensive audiologic assessments indicate great differences in performance between the two systems. These differences probably originate in differences in length of gap and in different suspension properties of the two transducer systems. This article will demonstrate that large gaps, such as in the transcutaneous transducer, can be devastating for power consumption, maximum output capability, and second harmonic distortion. Since the properties of the suspension in the transcutaneous transducer are not under adequate control and the complication risk of permanent skin penetration is low, we continue to concentrate our efforts on percutaneous transducer systems. © 1990, Official journal of the American Academy of Otolaryngology–Head and Neck Surgery Foundation. All rights reserved.
引用
收藏
页码:339 / 345
页数:7
相关论文
共 50 条
  • [21] SKULL SIMULATOR FOR DIRECT BONE CONDUCTION HEARING DEVICES
    HAKANSSON, B
    CARLSSON, P
    SCANDINAVIAN AUDIOLOGY, 1989, 18 (02): : 91 - 98
  • [22] Temporary Explant of a Transcutaneous Bone Conduction Hearing Implant for Imaging of the Pituitary Gland
    Roesch, Sebastian
    Kugler, Anton
    Schlattau, Alexander
    Rasp, Gerd
    OTOLOGY & NEUROTOLOGY, 2018, 39 (07) : e557 - e560
  • [23] Surgical Outcomes of Modified Technique for Transcutaneous Bone Conduction Hearing Aid Implantation
    Hicks, Kayla B.
    Brown, Kevin D.
    Selleck, A. Morgan
    Dedmon, Matthew M.
    Thompson, Nicholas J.
    LARYNGOSCOPE, 2024, 134 (05): : 2401 - 2404
  • [24] New Transcutaneous Bone Conduction Hearing Implant System: Surgical and Audiological Outcomes
    Swami, Himanshu
    Anand, Viswanathan
    Bhat, Sweekritha N.
    INDIAN JOURNAL OF OTOLOGY, 2018, 24 (04) : 252 - 256
  • [25] FORCE THRESHOLD FOR HEARING BY DIRECT BONE-CONDUCTION
    CARLSSON, P
    HAKANSSON, B
    RINGDAHL, A
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1995, 97 (02): : 1124 - 1129
  • [26] Hearing Outcomes of a New Cartilage Conduction Device vs Bone Conduction Devices
    Nairn, Emily M.
    Chen, Alyssa S.
    Nishimura, Tadashi
    Berezovsky, Anna
    Stucken, Emily Z.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2022, : 821 - 828
  • [27] The Functional Hearing Gain with an Active Transcutaneous Bone Conduction Implant Does Not Correlate with the Subjective Hearing Performance
    Auinger, Alice B.
    Liepins, Rudolfs
    Brkic, Faris E.
    Vyskocil, Erich
    Arnoldner, Christoph
    JOURNAL OF PERSONALIZED MEDICINE, 2022, 12 (07):
  • [28] Outcomes following conversion of a percutaneous to a transcutaneous bone conduction device in eight children
    Carr, S. D.
    Bruce, I. A.
    Jones, D.
    Ray, J.
    CLINICAL OTOLARYNGOLOGY, 2017, 42 (04) : 917 - 920
  • [29] Comparison of Satisfaction Between Patients Using Percutaneous and Transcutaneous Bone Conduction Devices
    Svagan, Matija
    Brzan, Petra Povalej
    Rebol, Janez
    OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : 651 - 657
  • [30] Hearing Rehabilitation Implementing a Transcutaneous Bone Conduction Device: Single-Center Experience
    Shokri, Tom
    Czarnecki, Beth
    Baker, Aaron
    Isildak, Huseyin
    ENT-EAR NOSE & THROAT JOURNAL, 2021, 100 (3_SUPPL) : 199S - 203S