EVALUATION OF A SIMPLE MODIFIED RADIOGRAPHIC ALIGNMENT SYSTEM FOR ROUTINE USE

被引:18
|
作者
CARPIO, LC [1 ]
HAUSMANN, E [1 ]
DUNFORD, RG [1 ]
ALLEN, KM [1 ]
CHRISTERSSON, LA [1 ]
机构
[1] SUNY BUFFALO,SCH DENT MED,PERIODONTAL DIS CLIN RES CTR,BUFFALO,NY
关键词
ALVEOLAR PROCESS RADIOGRAPHY; RADIOGRAPHY; DENTAL INSTRUMENTATION; DIAGNOSIS; COMPUTER-ASSISTED;
D O I
10.1902/jop.1994.65.1.62
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
RADIOGRAPHIC FRAMES USED FOR LONGITUDINAL STUDIES may be in part unreadable for measuring crestal bone change. Sites may not be present on the film, or the measurement reliability may be compromised because of dissimilar geometry. Several techniques used to address this problem are expensive, time-consuming, and require great skill. For the present study a commercially-available alignment system was simply modified by addition of a reference pin in the bite block, facilitating the repositioning of the film holder for a second exposure. This study determined the ability of the modified instrument to: 1) improve the geometrical correspondence between serial radiographs; and 2) reduce the frequency of missed sites in the film. Two pairs of x-rays were taken for each of 40 subjects, 1 pair with the standard alignment instrument of an assigned site and 1 pair with the modified instrument of the contralateral site. Measurements of alveolar bone height were performed using the ''side by side'' technique. The modified instrument yielded significantly smaller measurement differences and a significantly better geometrical correpondence than the conventional system (P<0.05). Also, the modified instrument yielded significantly greater (P<0.01) readable sites (86%) as compared to the conventional instrument (62%). The simply-modified instrument facilitates the correct interpretation of serial radiographs.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 50 条
  • [21] Evaluation of Erytra® Analyzer and DG Gel® System for Routine Use in Transfusion Laboratory
    Brown, M.
    Davies, L.
    Brown, R. E.
    Pointon, L.
    Chung, C.
    Barker, D.
    TRANSFUSION, 2011, 51 : 176A - 176A
  • [22] Evaluation of the automated phoenix system for potential routine use in the clinical microbiology laboratory
    Donay, JL
    Mathieu, D
    Fernandes, P
    Prégermain, C
    Bruel, P
    Wargnier, A
    Casin, I
    Weill, FX
    Lagrange, PH
    Herrmann, JL
    JOURNAL OF CLINICAL MICROBIOLOGY, 2004, 42 (04) : 1542 - 1546
  • [23] Evaluation of the BIOMIC video reader system for routine use in the clinical microbiology laboratory
    Geiss, HK
    Klar, UE
    DIAGNOSTIC MICROBIOLOGY AND INFECTIOUS DISEASE, 2000, 37 (03) : 151 - 155
  • [24] USE OF A MODIFIED OCCIPITAL VIEW FOR RADIOGRAPHIC EXAMINATION OF SKULL
    BURKE, RL
    CORWIN, LA
    ZIMMERMAN, D
    VETERINARY MEDICINE & SMALL ANIMAL CLINICIAN, 1978, 73 (04): : 460 - 463
  • [25] A SIMPLE LOW-COST COUNTING AND DATA REDUCTION SYSTEM FOR USE IN A ROUTINE ENDOCRINE LABORATORY
    HENNIKER, AJ
    AUSTRALIAN AND NEW ZEALAND JOURNAL OF MEDICINE, 1981, 11 (05): : 573 - 573
  • [26] AUTOMATED RADIOGRAPHIC IMAGE EVALUATION SYSTEM
    GRAY, GE
    NAVAL ENGINEERS JOURNAL, 1987, 99 (04) : 163 - 165
  • [27] EVALUATION OF A KINETIC CREATININE MODIFIED FOR USE ON GILFORD SYSTEM 3500
    FORRESTER, RL
    COLLINGE, W
    HASHIMOTO, P
    WORRALL, J
    CLINICAL CHEMISTRY, 1976, 22 (07) : 1217 - 1217
  • [28] MODIFIED MANCHESTER SYSTEM . ADAPTATION FOR AN ALIGNMENT APPLICATOR
    SCOTT, WP
    BRITISH JOURNAL OF RADIOLOGY, 1966, 39 (461): : 397 - &
  • [29] THE WHO BASIC RADIOGRAPHIC SYSTEM - AN EVALUATION OF 2 UNITS FOR USE IN A NHS DISTRICT HOSPITAL
    DELACEY, G
    PARIS, A
    DETAIN, J
    BRITISH JOURNAL OF RADIOLOGY, 1986, 59 (704): : 861 - 861
  • [30] Use of the iPhone for radiographic evaluation of hallux valgus
    Ege, Tolga
    Kose, Ozkan
    Koca, Kenan
    Demiralp, Bahtiyar
    Basbozkurt, Mustafa
    SKELETAL RADIOLOGY, 2013, 42 (02) : 269 - 273