EVALUATION OF A SIMPLE MODIFIED RADIOGRAPHIC ALIGNMENT SYSTEM FOR ROUTINE USE

被引:18
|
作者
CARPIO, LC [1 ]
HAUSMANN, E [1 ]
DUNFORD, RG [1 ]
ALLEN, KM [1 ]
CHRISTERSSON, LA [1 ]
机构
[1] SUNY BUFFALO,SCH DENT MED,PERIODONTAL DIS CLIN RES CTR,BUFFALO,NY
关键词
ALVEOLAR PROCESS RADIOGRAPHY; RADIOGRAPHY; DENTAL INSTRUMENTATION; DIAGNOSIS; COMPUTER-ASSISTED;
D O I
10.1902/jop.1994.65.1.62
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
RADIOGRAPHIC FRAMES USED FOR LONGITUDINAL STUDIES may be in part unreadable for measuring crestal bone change. Sites may not be present on the film, or the measurement reliability may be compromised because of dissimilar geometry. Several techniques used to address this problem are expensive, time-consuming, and require great skill. For the present study a commercially-available alignment system was simply modified by addition of a reference pin in the bite block, facilitating the repositioning of the film holder for a second exposure. This study determined the ability of the modified instrument to: 1) improve the geometrical correspondence between serial radiographs; and 2) reduce the frequency of missed sites in the film. Two pairs of x-rays were taken for each of 40 subjects, 1 pair with the standard alignment instrument of an assigned site and 1 pair with the modified instrument of the contralateral site. Measurements of alveolar bone height were performed using the ''side by side'' technique. The modified instrument yielded significantly smaller measurement differences and a significantly better geometrical correpondence than the conventional system (P<0.05). Also, the modified instrument yielded significantly greater (P<0.01) readable sites (86%) as compared to the conventional instrument (62%). The simply-modified instrument facilitates the correct interpretation of serial radiographs.
引用
收藏
页码:62 / 67
页数:6
相关论文
共 50 条
  • [1] Hindfoot coronal alignment: A modified radiographic method
    Johnson, JE
    Lamdan, R
    Granberry, WF
    Harris, GF
    Carrera, GF
    FOOT & ANKLE INTERNATIONAL, 1999, 20 (12) : 818 - 825
  • [2] Use of modified wooden crutches as an adjunct in the radiographic evaluation of the cervical spine
    Dula, DJ
    Rhames, MP
    Vollmer, TP
    Fitzpatrick, MH
    Botti, K
    Wood, GC
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2003, 54 (06): : 1250 - 1252
  • [3] SIMPLE UROFLOWMETER FOR ROUTINE USE
    TANKO, A
    TANKO, L
    SZOLLAR, G
    GAIZLER, G
    BALOGH, F
    ACTA CHIRURGICA ACADEMIAE SCIENTIARUM HUNGARICAE, 1977, 18 (03) : 317 - 320
  • [4] EVALUATION OF TRIMA ACCEL? 6.0 SYSTEM IN ROUTINE USE
    Areal Mendez, C.
    Forsberg, P. O.
    Leitner, G. C.
    Callaert, M.
    Green, T.
    Windscheid, V
    VOX SANGUINIS, 2010, 99 : 174 - 175
  • [5] Accuracy of the Tibial Component Alignment by Extramedullary System Using Simple Radiographic References in Total Knee Arthroplasty
    Cho, Jin-Ho
    Choi, Jun Young
    Lee, Sung-Sahn
    MEDICINA-LITHUANIA, 2022, 58 (09):
  • [6] SAMPLING OF PARTICULATE SUSPENSIONS FOR MORPHOLOGICAL EVALUATION - A SIMPLE METHOD FOR ROUTINE AND QUANTITATIVE USE
    AARONSON, RP
    JOURNAL OF MICROSCOPY-OXFORD, 1982, 128 (DEC): : 271 - 277
  • [7] SAMPLING OF PARTICULATE SUSPENSIONS FOR MORPHOLOGICAL EVALUATION - A SIMPLE METHOD FOR ROUTINE (QUANTITATIVE) USE
    AARONSON, RP
    JOURNAL OF CELL BIOLOGY, 1981, 91 (02): : A12 - A12
  • [10] The routine use of radiographic spinal displacement analysis: A dissent
    Haas, M
    Taylor, JAM
    Gillette, RG
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 1999, 22 (04) : 254 - 259