Comparative dosimetry of GammaMed Plus high-dose rate Ir-192 brachytherapy source

被引:6
|
作者
Patel, N. P. [1 ,2 ]
Majumdar, B. [1 ]
Vijayan, V. [3 ]
机构
[1] Govt Coll Sci, Dept Phys, Raipur, Madhya Pradesh, India
[2] AH Reg Canc Ctr, Dept Med Phys, Cuttack, Orissa, India
[3] Inst Phys, Bhubaneswar, Orissa, India
关键词
0.1-cc chamber; AAPM TG-43; dosimetry; EGSnrc simulation code; high dose rate;
D O I
10.4103/0971-6203.66761
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The comparative dosimetry of GammaMed (GM) Plus high-dose rate brachytherapy source was performed by an experiment using 0.1-cc thimble ionization chamber and simulation-based study using EGSnrc code. In-water dose measurements were performed with 0.1-cc chamber to derive the radial dose function (r = 0.8 to 20.0 cm) and anisotropy function (r = 5.0 cm with polar angle from 10 degrees to 170 degrees). The nonuniformity correction factor for 0.1-cc chamber was applied for in-water measurements at shorter distances from the source. The EGSnrc code was used to derive the dose rate constant (L), radial dose function g L (r) and anisotropy function F(r, q) of GM Plus source. The dosimetric data derived using EGSnrc code in our study were in very good agreement relative to published data for GM Plus source. The radial dose function up to 12 cm derived from measured dose using 0.1-cc chamber was in agreement within 3% of data derived by the simulation study.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [41] A dosimetric study on the Ir-192 high dose rate Flexisource
    Granero, D.
    Perez-Calatayud, J.
    Casal, E.
    Ballester, F.
    Venselaar, J.
    [J]. MEDICAL PHYSICS, 2006, 33 (12) : 4578 - 4582
  • [42] Dose calculation in brachytherapy for a Ir-192 source using a primary and scatter dose separation technique
    Russell, KR
    Ahnesjo, A
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1996, 41 (06): : 1007 - 1024
  • [43] Film dosimetry calibration method for pulsed-dose-rate brachytherapy with an 192Ir source
    Schwob, Nathan
    Orion, Itzhak
    [J]. MEDICAL PHYSICS, 2007, 34 (05) : 1678 - 1683
  • [44] Measurement of Transit Time of a Gammamed-Plus Remote Afterloading High Dose Rate Brachytherapy Source
    Supe, Sanjay S.
    Shwetha, B.
    Bijina, T. K.
    Varatharaj, C.
    Sathiyan, S.
    Ganesh, K. M.
    Arunkumar, T.
    Ravikumar, M.
    [J]. POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2007, 13 (02) : 55 - 63
  • [45] A standard graphite calorimeter for dosimetry in brachytherapy with high dose rate 192Ir sources
    Guerra, A. S.
    Loreti, S.
    Pimpinella, M.
    Quini, M.
    D'Arienzo, M.
    Astefanoaei, I.
    Caporali, C.
    Bolzan, C.
    Pagliari, M.
    [J]. METROLOGIA, 2012, 49 (05) : S179 - S183
  • [46] A Study on the Dose Distributions in Various Materials from an Ir-192 HDR Brachytherapy Source
    Hsu, Shih-Ming
    Wu, Chin-Hui
    Lee, Jeng-Hung
    Hsieh, Ya-Ju
    Yu, Chun-Yen
    Liao, Yi-Jen
    Kuo, Li-Cheng
    Liang, Ji-An
    Huang, David Y. C.
    [J]. PLOS ONE, 2012, 7 (09):
  • [47] A Monte Carlo study on dose distribution evaluation of Flexisource Ir-192 brachytherapy source
    Alizadeh, Majid
    Ghorbani, Mandi
    Haghparast, Abbas
    Zare, Naser
    Moghaddas, Toktam Ahmadi
    [J]. REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2015, 20 (03) : 204 - 209
  • [48] Dosimetry for Ir-192 HDR Brachytherapy - Present Status and Future Direction
    DeWerd, L.
    Seuntjens, J.
    Rivard, M.
    McEwen, M.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3884 - 3885
  • [49] A NEW REENTRANT IONIZATION-CHAMBER FOR THE CALIBRATION OF IR-192 HIGH-DOSE RATE SOURCES
    GOETSCH, SJ
    ATTIX, FH
    DEWERD, LA
    THOMADSEN, BR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1992, 24 (01): : 167 - 170
  • [50] Beta versus gamma dosimetry close to Ir-192 brachytherapy sources
    Baltas, D
    Karaiskos, P
    Papagiannis, P
    Sakelliou, L
    Loeffler, E
    Zamboglou, N
    [J]. MEDICAL PHYSICS, 2001, 28 (09) : 1875 - 1882