XSPRESS - X-RAY SIGNAL-PROCESSING ELECTRONICS FOR SOLID-STATE DETECTORS

被引:30
|
作者
FARROW, R
DERBYSHIRE, GE
DOBSON, BR
DENT, AJ
BOGG, D
HEADSPITH, J
LAWTON, R
MARTINI, M
BUXTON, K
机构
[1] DRAL Daresbury Laboratory, Warrington, WA4 4AD, Keckwick Lane, Daresbury
关键词
D O I
10.1016/0168-583X(94)00370-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
With recent improvements in synchrotron sources and X-ray optics great pressures have been placed on detector systems to produce higher count rates and better resolutions. Present high performance 13 element germanium detector systems can give reasonable count rates with good resolution (similar to 10(4)-10(5) Hz per channel and similar to 250 eV FWHM @ Fe-55 with 0.5 mu s shaping time). However, these systems are restricted by limitations in both the detector and in the analogue pulse processing after the detector. With respect to the detector, increasing the number of channels without degrading the energy resolution is a great challenge due to increased crosstalk and capacitance. The analogue pulse processing electronics are significantly limited by the dead time introduced by the shaping amplifier. This dead time causes pulse pile-up at higher rates which leads to non-linearity and poor resolution. This paper describes the XSPRESS system which has been developed at Daresbury Laboratory for the new Wiggler II beamline 16. This system overcomes previous limits in both signal processing and detector fabrication to give great improvements in system performance. The signal processing electronics departs from standard analogue processing techniques and employs sophisticated adaptive digital signal processing hardware to reduce the dead time associated with each event to a minimum. This VME based technology allows us to vastly increase the count rate for each channel yet still retain the ability to gain very good resolution. The detector has been developed through a collaborative agreement with EG and G Ortec and packs an unprecedented 30 germanium crystals into an extremely small area whilst still retaining the energy resolution of smaller arrays. This system has increased throughput rate by an order of magnitude per channel and when all channels are implemented, an increase of at least two orders of magnitude for the whole array should be seen. Data has been taken using this system on the SRS at Daresbury Laboratory and these results will be given along with a detailed explanation of the operation of this system.
引用
收藏
页码:567 / 571
页数:5
相关论文
共 50 条
  • [41] Solid State Organic X-Ray Detectors Based on Rubrene Single Crystals
    Basirico, Laura
    Ciavatti, Andrea
    Sibilia, Mirta
    Fraleoni-Morgera, Alessandro
    Trabattoni, Silvia
    Sassella, Adele
    Fraboni, Beatrice
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2015, 62 (04) : 1791 - 1797
  • [42] An evaluation of solid state detectors for the relative dosimetry of kilovoltage X-ray beams
    Daniel, John
    Yousif, Yousif A. M.
    Zifodya, Jackson
    Hill, Robin
    MEDICAL PHYSICS, 2022, 49 (06) : 4082 - 4091
  • [43] Progress in organic material based solid-state X-ray scintillators
    Zhao, Mengmeng
    Wan, Peng
    Shi, Junqing
    Ji, Lei
    JOURNAL OF MATERIALS CHEMISTRY C, 2025, 13 (11) : 5424 - 5438
  • [44] DC-CONTROLLED SOLID-STATE X-RAY IMAGE CONVERTER
    KOHASHI, T
    TANAKA, K
    SUZUKI, N
    MACHIDA, Y
    IEEE TRANSACTIONS ON ELECTRON DEVICES, 1972, ED19 (02) : 234 - &
  • [45] SPATIAL DISTORTIONS IN SOLID-STATE SEMICONDUCTOR IMAGERS IN X-RAY REGION
    FEDOTOV, MG
    KUPER, EA
    PANCHENKO, VE
    TIUNOV, SA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1989, 60 (07): : 2333 - 2333
  • [46] SOLID-STATE ELECTROPHOTOGRAPHIC IMAGING WITH IONIC DIELECTRIC X-RAY RECEPTORS
    DEWERD, LA
    MORAN, PR
    JOURNAL OF APPLIED PHOTOGRAPHIC ENGINEERING, 1977, 3 (03): : 163 - 166
  • [47] X-RAY STUDIES ON DIETHYNYLBENZENE DERIVATIVES IN VIEW OF THE SOLID-STATE POLYMERIZATION
    KAI, Y
    YAMAMOTO, A
    XU, DJ
    KASAI, N
    HAGIHARA, M
    YAMAMOTO, Y
    TAKAHASHI, S
    HAYASHI, K
    MAKROMOLEKULARE CHEMIE-MACROMOLECULAR CHEMISTRY AND PHYSICS, 1987, 188 (12): : 3047 - 3059
  • [48] SOLID-STATE EFFECT ON THE ANOMALOUS X-RAY ATOMIC SCATTERING FACTOR
    WANG, MS
    CHIA, SH
    PHYSICAL REVIEW A, 1988, 37 (08): : 2968 - 2969
  • [49] Theory of solid-state contributions to the x-ray elastic scattering amplitude
    Ankudinov, AL
    Rehr, JJ
    PHYSICAL REVIEW B, 2000, 62 (04): : 2437 - 2445