A MATHEMATICAL DESCRIPTION OF THE METROLOGICAL CHARACTERISTICS OF PULSE ACOUSTIC FLOWMETERS

被引:1
|
作者
Buzanovskii, V. A. [1 ]
机构
[1] Bezopasnost Co, Moscow, Russia
关键词
pulse acoustic flowmeter; metrological characteristic; static characteristic; measurement sensitivity; measurement error;
D O I
10.1007/s10556-014-9913-y
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A mathematical description of the basic metrological characteristics of pulse acoustic flowmeters is developed in the article. An analysis of the mathematical description is carried out, as a result of which the basic sources of errors in the measurement of the rate of flow of the substance are determined, a possible method of increasing the measurement precision is indicated, and a design for the assembly of the flowmeter that increases the measurement sensitivity is proposed.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条