UPGRADING A 1929 RIVETED-DRUM POWER BOILER

被引:0
|
作者
BARSIN, JA [1 ]
CLAYPOOL, RC [1 ]
机构
[1] CHAMPION INT CORP, HAMILTON, OH 45013 USA
来源
TAPPI JOURNAL | 1990年 / 73卷 / 07期
关键词
D O I
暂无
中图分类号
TB3 [工程材料学]; TS [轻工业、手工业、生活服务业];
学科分类号
0805 ; 080502 ; 0822 ;
摘要
引用
收藏
页码:65 / 72
页数:8
相关论文
共 50 条
  • [41] Control Level of Boiler Drum Utilizing LabVIEW
    Suresh, A.
    Krishna, G. Vamsi
    Bhaskar, B.
    2016 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND COMPUTING RESEARCH, 2016, : 721 - 724
  • [42] Acid cleaning operation for a natural circulation high pressure drum boiler unit of a thermal power station
    Sohail, MA
    Mustafa, AI
    INDIAN JOURNAL OF CHEMICAL TECHNOLOGY, 2001, 8 (03) : 223 - 226
  • [43] Formal Analysis of Drum-Boiler Units to Maximize the Load-Following Capabilities of Power Plants
    El-Guindy, Ahmed
    Han, Dongkun
    Althoff, Matthias
    IEEE TRANSACTIONS ON POWER SYSTEMS, 2016, 31 (06) : 4691 - 4702
  • [44] Developing a control system for correction treatment of the feedwater and the boiler water of drum boilers at thermal power stations
    All-Russia Thermal Eng. Inst. , ul. Avtozavodskaya 14/23, Moscow, 109280, Russia
    Thermal Engineering, 2000, 47 (09) : 792 - 795
  • [45] Is the internal caulking of steam boiler-riveted joints generally regulated?
    Bach, C
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1912, 56 : 2071 - 2072
  • [46] A Method For Alarming Water Level of Boiler Drum on Nuclear Power Plant Based on BP Neural Network
    Quan, Yalei
    Yang, Xuhong
    2014 10TH INTERNATIONAL CONFERENCE ON NATURAL COMPUTATION (ICNC), 2014, : 83 - 87
  • [47] Application of hysteresis switching in adaptive control of coal-fired power plant boiler drum level
    Bi Zhenfu
    Xu Changbo
    PROCEEDINGS OF THE 24TH CHINESE CONTROL CONFERENCE, VOLS 1 AND 2, 2005, : 812 - 816
  • [48] The control system of a gas-oil drum boiler for a semi-peak-load power unit
    Vasil'ev, V.I.
    Chernov, A.S.
    Thermal Engineering, 2000, 47 (09) : 761 - 768
  • [49] Influence of Boiler Load Swing Rates on Effective Stresses of Drum Boiler Riser Tubes
    Habib, M. A.
    Al-Zaharnah, I.
    El-Shafei, M.
    Said, S. A. M.
    Merah, N.
    Al-Anizi, S.
    Al-Awwad, M. Y.
    Hajji, M.
    JOURNAL OF PRESSURE VESSEL TECHNOLOGY-TRANSACTIONS OF THE ASME, 2010, 132 (06): : 0613011 - 0613018
  • [50] The Temperature of a Water-Wall Tube in a Drum Boiler
    Kholshchev, V.V.
    Thermal Engineering, 1998, 45 (10): : 839 - 841