MICROBORE LIQUID-CHROMATOGRAPHY FOR ANALYSIS OF PLASMA PINDOLOL CONCENTRATIONS

被引:2
|
作者
WANWIMOLRUK, S
机构
[1] Department of Pharmacy, University of Otago Medical School, Dunedin
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1991年 / 14卷 / 09期
关键词
D O I
10.1080/01483919108049647
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Isocratic high-performance liquid chromatographic assay of pindolol with use of a microbore column was developed. The sample preparation involves extraction of alkalized plasma into ether and back extraction into 0.05 N H2SO4. Metoprolol was used as the internal standard. Chromatographic separation is performed on a microbore C18 (5-mu-m) column using acetonitrile-disodium hydrogenphosphate buffer (37:63) containing 20 mM sodium dodecyl sulfate as the mobile phase. The detection is achieved by using a fluorescence detector operated at the excitation and emission wavelengths of 260 and 310 nm, respectively. Acceptable reproducibility and accuracy data are presented over the concentration range normally encountered in human plasma samples. The lower detection limit is 2.5 ng/ml. This sensitivity has been found to be adequate for routine analysis of pindolol in human plasma samples, making the method applicable to pharmacokinetic studies and clinical trials.
引用
收藏
页码:1699 / 1706
页数:8
相关论文
共 50 条
  • [11] DETERMINATION OF HISTAMINE CONCENTRATIONS IN PLASMA BY LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY
    HARSING, LG
    NAGASHIMA, H
    DUNCALF, D
    VIZI, ES
    GOLDINER, PL
    CLINICAL CHEMISTRY, 1986, 32 (10) : 1823 - 1827
  • [12] SENSITIVE PHOTOTHERMAL DEFLECTION DETECTOR FOR MICROBORE LIQUID-CHROMATOGRAPHY
    COLLETTE, TW
    PAREKH, NJ
    GRIFFIN, JH
    CARREIRA, LA
    ROGERS, LB
    APPLIED SPECTROSCOPY, 1986, 40 (02) : 164 - 169
  • [13] DESIGN AND USE OF SHORT MICROBORE COLUMNS IN LIQUID-CHROMATOGRAPHY
    KUCERA, P
    JOURNAL OF CHROMATOGRAPHY, 1980, 198 (02): : 93 - 109
  • [14] DIRECT AND INDIRECT POLARIMETRY FOR DETECTION IN MICROBORE LIQUID-CHROMATOGRAPHY
    BOBBITT, DR
    YEUNG, ES
    ANALYTICAL CHEMISTRY, 1984, 56 (09) : 1577 - 1581
  • [15] SIMULTANEOUS DETERMINATION OF CARBAMAZEPINE AND ITS EPOXIDE AND TRANSDIOL METABOLITES IN PLASMA BY MICROBORE LIQUID-CHROMATOGRAPHY
    RIAD, LE
    SAWCHUK, RJ
    CLINICAL CHEMISTRY, 1988, 34 (09) : 1863 - 1866
  • [16] ANALYSIS OF VERAPAMIL IN PLASMA BY LIQUID-CHROMATOGRAPHY
    JAOUNI, TM
    LEON, MB
    ROSING, DR
    FALES, HM
    JOURNAL OF CHROMATOGRAPHY, 1980, 182 (3-4): : 473 - 477
  • [17] SCREENING OF AMPHETAMINES BY GRADIENT MICROBORE LIQUID-CHROMATOGRAPHY AND PRECOLUMN TECHNOLOGY
    SLAIS, K
    NIELEN, MWF
    BRINKMAN, UAT
    FREI, RW
    JOURNAL OF CHROMATOGRAPHY, 1987, 393 (01): : 57 - 68
  • [18] SAMPLING CONSIDERATIONS FOR ONLINE MICROBORE LIQUID-CHROMATOGRAPHY OF BRAIN DIALYSATE
    WAGES, SA
    CHURCH, WH
    JUSTICE, JB
    ANALYTICAL CHEMISTRY, 1986, 58 (08) : 1649 - 1656
  • [19] MICRODIALYSIS SAMPLING COUPLED ONLINE TO FAST MICROBORE LIQUID-CHROMATOGRAPHY
    CHEN, AQ
    LUNTE, CE
    JOURNAL OF CHROMATOGRAPHY A, 1995, 691 (1-2) : 29 - 35
  • [20] REFRACTIVE-INDEX DETECTION IN MICROBORE COLUMN LIQUID-CHROMATOGRAPHY
    FUJIMOTO, C
    MORITA, T
    JINNO, K
    CHROMATOGRAPHIA, 1986, 22 (1-6) : 91 - 94