COMPARISON OF ON-AXIS AND OFF-AXIS PHOTOREFRACTION WITH CYCLOPLEGIC RETINOSCOPY IN INFANTS

被引:0
|
作者
HAMER, RD
NORCIA, AM
DAY, SH
HAEGERSTROMPORTNOY, G
LEWIS, D
HSUWINGES, C
机构
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We have compared the performance of an off-axis (knife-edge) photorefractor with that of an on-axis (isotropic) system. Normal infants and children between the ages of 8 and 208 weeks were photographed with each camera both with and without cycloplegia. Refractive errors were estimated for each technique based on equations derived from ray-tracing. These refractions were compared to the results of retinoscopy under cycloplegia. Sensitivity and specificity of the two photorefraction systems were evaluated as a function of the magnitude of meridional hyperopia defined by retinoscopy. We also examined the effect of varying the photorefraction screening criterion. Thirteen percent of the infants in the screening sample presented with + 3.50 diopters or more of meridional hyperopia. Using this level of ametropia as a referral criterion, the sensitivity and specificity of the off-axis system for infants without cycloplegia were 83% and 72%, respectively. For the on-axis system, sensitivity and specificity values were 85% and 53%. The use of cycloplegics did not significantly improve the performance of either system, but rather their use degraded the specificity of the on-axis system in the presence of moderate refractive errors. The results of the present study indicate that both on- and off-axis systems are effective in identifying highly ametropic infants, but that the off-axis system results in significantly fewer false positives. Moreover, the off-axis system has the advantages of an inherently greater dynamic range for a fixed camera design, and also more easily interpreted photographs.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [22] Propagation of on-axis and off-axis Bessel beams in a gradient-index medium
    Cao, Zhaolou
    Zhai, Chunjie
    Xu, Shanshan
    Chen, Yunyun
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 2018, 35 (02) : 230 - 235
  • [23] Using the on-axis BSDF at a dielectric surface to model the BSDF at off-axis angles
    Cassarly, William J.
    ILLUMINATION OPTICS II, 2011, 8170
  • [24] Fatigue Damage in On-Axis and Off-Axis Woven-Fiber/Resin Composite
    Montesano, John
    Fawaz, Zouheir
    Behdinan, Kamran
    Poon, Cheung
    ADVANCES IN FRACTURE AND DAMAGE MECHANICS X, 2012, 488-489 : 230 - 233
  • [25] COMPARISON BETWEEN NEAR RETINOSCOPY AND CYCLOPLEGIC RETINOSCOPY IN THE REFRACTION OF INFANTS AND CHILDREN
    SAUNDERS, KJ
    WESTALL, CA
    OPTOMETRY AND VISION SCIENCE, 1992, 69 (08) : 615 - 622
  • [26] Polarization comparison between on-axis and off-axis dual reflector telescopes: Zemax and Grasp8 simulations
    Tran, HT
    NEW ASTRONOMY REVIEWS, 2003, 47 (11-12) : 1091 - 1096
  • [27] ON-AXIS AND OFF-AXIS PRIMARY DOSE COMPONENT IN HIGH-ENERGY PHOTON BEAMS
    ZEFKILI, S
    KAPPAS, C
    ROSENWALD, JC
    MEDICAL PHYSICS, 1994, 21 (06) : 799 - 808
  • [28] Creep of plain weave polymer matrix composites under on-axis and off-axis loading
    Gupta, Abhishek
    Raghavan, J.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2010, 41 (09) : 1289 - 1300
  • [29] Characterization of Failure Strain In Fiber Reinforced Composites: Under On-Axis and Off-Axis Loading
    Khalid, Muhammad Yasir
    Al Rashid, Ans
    Arif, Zia Ullah
    Akram, Naveed
    Arshad, Hassan
    Garcia Marquez, Fausto Pedro
    CRYSTALS, 2021, 11 (02): : 1 - 11
  • [30] Off-axis imaging with off-axis parabolic mirrors
    Liu, Albert
    APPLIED OPTICS, 2023, 62 (32) : 8574 - 8576