COMPARISON OF ON-AXIS AND OFF-AXIS PHOTOREFRACTION WITH CYCLOPLEGIC RETINOSCOPY IN INFANTS

被引:0
|
作者
HAMER, RD
NORCIA, AM
DAY, SH
HAEGERSTROMPORTNOY, G
LEWIS, D
HSUWINGES, C
机构
关键词
D O I
暂无
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
We have compared the performance of an off-axis (knife-edge) photorefractor with that of an on-axis (isotropic) system. Normal infants and children between the ages of 8 and 208 weeks were photographed with each camera both with and without cycloplegia. Refractive errors were estimated for each technique based on equations derived from ray-tracing. These refractions were compared to the results of retinoscopy under cycloplegia. Sensitivity and specificity of the two photorefraction systems were evaluated as a function of the magnitude of meridional hyperopia defined by retinoscopy. We also examined the effect of varying the photorefraction screening criterion. Thirteen percent of the infants in the screening sample presented with + 3.50 diopters or more of meridional hyperopia. Using this level of ametropia as a referral criterion, the sensitivity and specificity of the off-axis system for infants without cycloplegia were 83% and 72%, respectively. For the on-axis system, sensitivity and specificity values were 85% and 53%. The use of cycloplegics did not significantly improve the performance of either system, but rather their use degraded the specificity of the on-axis system in the presence of moderate refractive errors. The results of the present study indicate that both on- and off-axis systems are effective in identifying highly ametropic infants, but that the off-axis system results in significantly fewer false positives. Moreover, the off-axis system has the advantages of an inherently greater dynamic range for a fixed camera design, and also more easily interpreted photographs.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 50 条
  • [1] ON-AXIS AND OFF-AXIS REFRACTIONS OF INFANTS
    EHRLICH, DL
    ANKER, S
    BRADDICK, OJ
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1806 - 1806
  • [2] Comparison of non-cycloplegic photorefraction, cycloplegic photorefraction and cycloplegic retinoscopy in children
    Ozdemir, Ozdemir
    Tunay, Zuhal Ozen
    Petricli, Ikbal Seza
    Acar, Damla Erginturk
    Erol, Muhammet Kazim
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (01) : 128 - 131
  • [3] Comparison of non-cycloplegic photorefraction,cycloplegic photorefraction and cycloplegic retinoscopy in children
    Ozdemir Ozdemir
    Zuhal ?zen Tunay
    Ikbal Seza Petrili
    Damla Ergintürk Acar
    Muhammet Kazim Erol
    International Journal of Ophthalmology, 2015, (01) : 128 - 131
  • [4] A comparison of on-axis and off-axis heliostat alignment strategies
    Jones, SA
    SOLAR '96 - THE 1996 AMERICAN SOLAR ENERGY SOCIETY ANNUAL CONFERENCE, PROCEEDINGS OF, 1996, : 95 - 100
  • [5] A systematic comparison of on-axis and off-axis transmission Kikuchi diffraction
    Niessen, F.
    Burrows, A.
    Fanta, A. Bastos da Silva
    ULTRAMICROSCOPY, 2018, 186 : 158 - 170
  • [6] COMPLEX SECTORS AND MULTIVARIABLE ON-AXIS AND OFF-AXIS CIRCLE CRITERIA
    KOUVARITAKIS, B
    HUSBAND, R
    IEE PROCEEDINGS-D CONTROL THEORY AND APPLICATIONS, 1984, 131 (06): : 209 - 220
  • [7] Optical sensitivity analyses of various reflective systems: on-axis, common off-axis, and confocal off-axis designs
    Park, Woojin
    Pak, Soojong
    Chang, Seunghyuk
    Lee, Hanshin
    Lee, Sunwoo
    Kim, Dae Wook
    ADVANCES IN OPTICAL AND MECHANICAL TECHNOLOGIES FOR TELESCOPES AND INSTRUMENTATION IV, 2020, 11451
  • [8] HEAT-TRANSPORT WITH STRONG ON-AXIS AND OFF-AXIS HEATING
    BALET, B
    CORDEY, JG
    NUCLEAR FUSION, 1994, 34 (08) : 1175 - 1181
  • [9] THEORETICAL-ANALYSIS OF OFF-AXIS STREAK RETINOSCOPY
    KEATING, MP
    AMERICAN JOURNAL OF OPTOMETRY AND PHYSIOLOGICAL OPTICS, 1975, 52 (11): : 750 - 757
  • [10] ON-AXIS AND OFF-AXIS PROPAGATION OF GAUSSIAN BEAMS IN GRADIENT INDEX MEDIA
    ALDA, J
    BOREMAN, GD
    APPLIED OPTICS, 1990, 29 (19): : 2944 - 2950