Comparison of Different Cuff Pressure Use with the Supreme Laryngeal Mask Airway on Haemodynamic Response, Seal Pressure and Postoperative Adverse Events: A Prospective Randomized Study

被引:6
|
作者
Ali, Achmet [1 ]
Altun, Demet [1 ]
Sivrikoz, Nukhet [1 ]
Yornuk, Mesut [1 ]
Turgut, Namigar [2 ]
Akinci, Ibrahim Ozkan [1 ]
机构
[1] Istanbul Univ, Istanbul Sch Med, Dept Anaesthesiol, Istanbul, Turkey
[2] Okmeydani Training & Res Hosp, Dept Anaesthesiol, Istanbul, Turkey
关键词
Laryngeal mask airway supreme; general anaesthesia; haemodynamic response; cuff pressure; seal pressure;
D O I
10.5152/TJAR.2017.89587
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Objective: The Supreme (TM) laryngeal mask airway (SLMA) is a supra glottic airway (SGA) device that is used as an alternative to endotracheal tubes. In the present study, we aimed to compare the use of the SLMA with normal cuff pressure and low cuff pressure, primarily for haemodynamic response. Methods: In the present study, 120 patients diagnosed with hypertension and scheduled for varicose vein or inguinal hernia operation were enrolled and 99 patients finished. Using randomization, patients were divided into two groups according to cuff pressure as a low-pressure group (Group L, 45 cm H2O) and a normal-pressure group (Group N, 60 cm H2O). Demographics, Mallampati score and the type and duration of surgery, heart rate (HR), mean arterial pressure (MAP), percentage of tidal volume leakage, Ppeak, Pmean, etCO(2), seal pressure, fibreoptic scores and postoperative adverse effects of all patients were recorded. Results: MAP and HR values immediately and 2 minutes after SLMA insertion were significantly lower in Group L (p<0.001). In Group L and Group N, the seal pressures were 24.1 +/- 3.1 cm H2O and 26.2 +/- 3.9 cm H2O, respectively (p=0.003). Also, blood staining and sore throat occurred less frequently in Group L (p<0.05). The fibreoptic average score, insertion features and ventilation parameters were similar between the groups (p>0.05). Conclusion: SLMA use with a cuff pressure of 45 cm H2O significantly decreases haemodynamic response and post-operative side effects compared with a normal cuff pressure. Therefore, except for some specific surgeries that require higher seal pressures, we recommend the use of the SLMA with cuff pressures as low as 45 cm H2O.
引用
收藏
页码:151 / 157
页数:7
相关论文
共 50 条
  • [31] Baska mask vs ProSeal Laryngeal mask on airway seal pressure in cases undergoing general anesthesia by mechanical ventilation: A randomized controlled trial
    Rady Abdalla, Shady
    Mohamed, Ahmed Abdalla
    Roshdy, Marianne Magdy
    Ismail, Maha Mohamed
    Abdelreheem, Ashraf Mohamed
    Bahnas, Walaa Mohamed
    Soliman, Mahmoud Salem
    EGYPTIAN JOURNAL OF ANAESTHESIA, 2023, 39 (01): : 673 - 679
  • [32] A RANDOMISED CONTROLLED STUDY OF COMPARISON OF INTRAOCULAR PRESSURE AND HAEMODYNAMIC RESPONSES TO INSERTION OF THE I-GEL, CLASSICAL LARYNGEAL MASK AIRWAY AND ENDOTRACHEAL TUBE
    Khot, Aditya
    Jamale, P. B.
    Dhulkhed, V. K.
    Naik, Shraddha
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2016, 5 (41): : 2614 - 2619
  • [33] Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
    Fan, Hongna
    Li, Lin
    Zhu, Lei
    Yi, Zhuo
    Diao, Yugang
    BMC ANESTHESIOLOGY, 2022, 22 (01)
  • [34] Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study
    Hongna Fan
    Lin Li
    Lei Zhu
    Zhuo Yi
    Yugang Diao
    BMC Anesthesiology, 22
  • [35] Supreme™ laryngeal mask airway use in general Anesthesia for category 2 and 3 Cesarean delivery: a prospective cohort study
    Li, Shi Yang
    Yao, Wei Yu
    Yuan, Yong Jin
    Tay, Wen Shu
    Han, Nian-Lin Reena
    Sultana, Rehena
    Assam, Pryseley N.
    Sia, Alex Tiong-Heng
    Sng, Ban Leong
    BMC ANESTHESIOLOGY, 2017, 17
  • [36] Supreme™ laryngeal mask airway use in general Anesthesia for category 2 and 3 Cesarean delivery: a prospective cohort study
    Shi Yang Li
    Wei Yu Yao
    Yong Jin Yuan
    Wen Shu Tay
    Nian-Lin Reena Han
    Rehena Sultana
    Pryseley N. Assam
    Alex Tiong-Heng Sia
    Ban Leong Sng
    BMC Anesthesiology, 17
  • [37] Pressure support ventilation versus continuous positive airway pressure ventilation with the ProSealTM laryngeal mask airway:: A randomized crossover study of anesthetized pediatric patients
    von Goedecke, A
    Brimacombe, J
    Hörmann, C
    Jeske, HC
    Kleinsasser, A
    Keller, C
    ANESTHESIA AND ANALGESIA, 2005, 100 (02): : 357 - 360
  • [38] Use of the ProSeal™ laryngeal mask airway for pressure-controlled ventilation with and without positive end-expiratory pressure in paediatric patients:: a randomized, controlled study
    Goldmann, K
    Roettger, C
    Wulf, H
    BRITISH JOURNAL OF ANAESTHESIA, 2005, 95 (06) : 831 - 834
  • [39] Techniques for the insertion of the proseal laryngeal mask airway: comparison of the foley airway stylet tool with the introducer tool in a prospective, randomized study
    Mao-Kai Chen
    Hung-Te Hsu
    I-Cheng Lu
    Chih-Kai Shih
    Ya-Chun Shen
    Kuang-Yi Tseng
    Kuang-I Cheng
    BMC Anesthesiology, 14
  • [40] Techniques for the insertion of the proseal laryngeal mask airway: comparison of the foley airway stylet tool with the introducer tool in a prospective, randomized study
    Chen, Mao-Kai
    Hsu, Hung-Te
    Lu, I-Cheng
    Shih, Chih-Kai
    Shen, Ya-Chun
    Tseng, Kuang-Yi
    Cheng, Kuang-I
    BMC ANESTHESIOLOGY, 2014, 14