GLUCOSE BIOSENSOR BASED ON THE INCORPORATION OF MELDOLA BLUE AND GLUCOSE-OXIDASE WITHIN CARBON-PASTE

被引:32
|
作者
KULYS, J [1 ]
HANSEN, HE [1 ]
BUCHRASMUSSEN, T [1 ]
WANG, J [1 ]
OZSOZ, M [1 ]
机构
[1] NEW MEXICO STATE UNIV,DEPT CHEM & BIOCHEM,LAS CRUCES,NM 88003
关键词
BIOSENSORS; GLUCOSE; GLUCOSE OXIDASE; MELDOLA BLUE MEDIATOR;
D O I
10.1016/0003-2670(93)E0610-J
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The phenoxazine compound Meldola Blue (MB) is shown to efficiently mediate the electron transfer from reduced glucose oxidase to a conventional carbon paste electrode. The mediation process is exploited for developing an amperometric biosensor for glucose, which yields a linear response to 0-25 mM glucose at an operating potential of 50 mV (vs. SCE), where interfering reactions do not occur. Experimental variables such as enzyme loading or operating potential are explored. A stable response is observed over several months.
引用
收藏
页码:193 / 196
页数:4
相关论文
共 50 条
  • [41] Reagentless amperometric biosensor highly sensitive to hydrogen peroxide based on the incorporation of Meldola Blue, fumed silica and horseradish peroxidase into carbon paste
    Liu, HY
    Zhang, ZN
    Fan, YB
    Dai, M
    Zhang, XL
    Wei, JJ
    Qiu, ZN
    Li, HB
    Wu, XX
    Deng, JQ
    Qi, DY
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 357 (03): : 297 - 301
  • [42] Modeling of Enzyme-FET Biosensor Based on Experimental Glucose-Oxidase Receptor
    Ravariu, Cristian
    Arora, Vijay
    2021 43RD ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY (EMBC), 2021, : 4333 - 4336
  • [43] REDOX REACTIONS OF GLUCOSE-OXIDASE AT CARBON MATERIALS
    ATANASOV, P
    BOGDANOVSKAYA, VA
    ILIEV, I
    TARASEVICH, MR
    VOROBEV, VG
    SOVIET ELECTROCHEMISTRY, 1989, 25 (11): : 1320 - 1325
  • [44] IMMOBILIZATION OF GLUCOSE-OXIDASE WITH POLYURETHANE ON CARBON SUPPORT
    PHADKE, RS
    ALVA, S
    GOVIL, G
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS SCIENCE AND TECHNOLOGY SECTION A-MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 1993, 234 : 415 - 419
  • [45] Glucose biosensor based on immobilization of glucose oxidase on a carbon paste electrode modified with microsphere-attached L-glycine
    Donmez, Soner
    Arslan, Fatma
    Sari, Nursen
    Ozkan, Elvan Hasanoglu
    Arslan, Halit
    BIOTECHNOLOGY AND APPLIED BIOCHEMISTRY, 2017, 64 (05) : 745 - 753
  • [46] Evaluation of chrono-impedance technique as transduction method for a carbon paste/glucose oxidase (CP/GOx) based glucose biosensor
    Mayorga Martinez, Carmen C.
    Treo, Ernesto F.
    Madrid, Rossana E.
    Felice, Carmelo C.
    BIOSENSORS & BIOELECTRONICS, 2010, 26 (04): : 1239 - 1244
  • [47] Reagentless glucose biosensor based on direct electron transfer of glucose oxidase immobilized on colloidal gold modified carbon paste electrode
    Liu, SQ
    Ju, HX
    BIOSENSORS & BIOELECTRONICS, 2003, 19 (03): : 177 - 183
  • [48] AMPEROMETRIC GLUCOSE SENSORS BASED ON GLUCOSE-OXIDASE IMMOBILIZED IN NAFION
    RISHPON, J
    GOTTESFELD, S
    CAMPBELL, C
    DAVEY, J
    ZAWODZINSKI, TA
    ELECTROANALYSIS, 1994, 6 (01) : 17 - 21
  • [49] OXYGEN-INDEPENDENT GLUCOSE MICROSENSOR BASED ON GLUCOSE-OXIDASE
    CRONENBERG, C
    VANGROEN, B
    DEBEER, D
    VANDENHEUVEL, H
    ANALYTICA CHIMICA ACTA, 1991, 242 (02) : 275 - 278
  • [50] Amperometric determination of glucose with a carbon paste biosensor
    Schachl, K
    Turkusic, E
    Komersová, A
    Bartos, M
    Moderegger, H
    Svancara, I
    Alemu, H
    Vytras, K
    Jimenez-Castro, M
    Kalcher, K
    COLLECTION OF CZECHOSLOVAK CHEMICAL COMMUNICATIONS, 2002, 67 (03) : 302 - 313