FEASIBILITY STUDY FOR POSITRON EMISSION MAMMOGRAPHY

被引:133
|
作者
THOMPSON, CJ
MURTHY, K
WEINBERG, IN
MAKO, F
机构
[1] MCGILL UNIV,MONTREAL NEUROL INST,MONTREAL,PQ,CANADA
[2] JOHNS HOPKINS UNIV,DEPT RADIOL,BALTIMORE,MD
[3] FM TECHNOL INC,FAIRFAX,VA
关键词
PET; MAMMOGRAPHY; SPATIAL RESOLUTION;
D O I
10.1118/1.597169
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A feasibility study is presented for a small, low-cost, dedicated device for positron emission mammography. Two detector arrays above and below the breast would be placed in a conventional mammography unit. These detectors are sensitive to positron annihilation radiation, and are connected to a coincidence circuit and a multiplane image memory. Images of the distribution of positron-emitting isotope are obtained in real time by incrementing the memory location at the intersection of each line of response. Monte Carlo simulations of a breast phantom are compared with actual scans of this phantom in a conventional PET scanner. The simulations and experimental data are used to predict the performance of the proposed system. Spatial resolution experiments using very narrow bismuth germanate BGO crystals suggest that spatial resolutions of about 2 mm should be possible. The efficiency of the proposed device is about ten times that of a conventional brain scanner. The scatter fraction is greater, but the scattered radiation has a very flat distribution. By designing the device to fit in an existing mammography unit, conventional mammograms can be taken after the injection of the radio-pharmaceutical allowing exact registration of the emission and conventional mammographic images.
引用
收藏
页码:529 / 538
页数:10
相关论文
共 50 条
  • [1] FEASIBILITY STUDY FOR LOW-DOSE POSITRON EMISSION MAMMOGRAPHY
    WEINBERG, IN
    THOMPSON, CJ
    MURTHY, K
    MAKO, F
    [J]. JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) : P61 - P62
  • [2] Feasibility study of using PEImager scanner for positron emission mammography
    Jan, ML
    Chuang, KS
    Ni, YC
    Pei, CC
    Wu, J
    Yeh, CK
    Fu, YK
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1406 - 1412
  • [3] Feasibility study of a new prototype positron emission mammography (PEM)
    Tzen, Kai-Yuan
    Jan, Meei-Ling
    Ni, Yu-Ching
    Yeh, Jia-Yi
    Huang, Chiun-Sheng
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] Feasibility study of using PEImager scanner for positron emission mammography
    Jan, ML
    Chuang, KS
    Ni, YC
    Wu, J
    Pei, CC
    Yeh, CK
    Fu, YK
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 2594 - 2598
  • [5] Positron emission mammography (PEM)
    Garcia-Gomez, Jaime I.
    Villasenor-Navarro, Yolanda
    [J]. GACETA MEXICANA DE ONCOLOGIA, 2012, 11 (04): : 281 - 287
  • [6] Positron emission mammography imaging
    Moses, WW
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2): : 249 - 252
  • [7] Applications for positron emission mammography
    Weinberg, Irving N.
    [J]. PHYSICA MEDICA, 2006, 21 : 132 - 137
  • [8] Instrumentation for Positron Emission Mammography
    Thompson, Christopher J.
    [J]. PET CLINICS, 2006, 1 (01) : 33 - 38
  • [9] Instrumentation optimization for Positron Emission Mammography
    Moses, WW
    Qi, JY
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 527 (1-2): : 76 - 82
  • [10] Fundamental limits of positron emission mammography
    Moses, WW
    Qi, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 497 (01): : 82 - 89