HIGH MASS-RESOLUTION USING A QUADRUPOLE ION-TRAP MASS-SPECTROMETER

被引:54
|
作者
WILLIAMS, JD
COX, KA
COOKS, RG
KAISER, RE
SCHWARTZ, JC
机构
[1] FINNIGAN MAT CORP,SAN JOSE,CA 95134
[2] PURDUE UNIV,DEPT CHEM,W LAFAYETTE,IN 47907
[3] ELI LILLY & CO,LILLY RES LAB,INDIANAPOLIS,IN 46285
关键词
D O I
10.1002/rcm.1290050706
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Modifications have been made to the quadrupole ion-trap mass spectrometer (ITMS) to improve the resolution. An offset-digital-to-analog converter/attenuator network is used to slow down the scan rate in the mass-selective instability mode of operation with resonance ejection. Attenuations of the scan rate by 200 to 700 times increase the resolution from 500 (with no attenuation) to 40 000 and to 100 000 (full width at half maximum), respectively, for the [M + H]+ peak of substance P (m/z 1348). These improved resolutions are achieved in experiments which use resonance ejection to extend the mass-to-charge range.
引用
收藏
页码:327 / 329
页数:3
相关论文
共 50 条
  • [31] ION ISOLATION AND SEQUENTIAL STAGES OF MASS-SPECTROMETRY IN A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    LOURIS, JN
    BRODBELTLUSTIG, JS
    COOKS, RG
    GLISH, GL
    VANBERKEL, GJ
    MCLUCKEY, SA
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 96 (02): : 117 - 137
  • [32] MULTIPLE STAGES OF MASS-SPECTROMETRY IN A QUADRUPOLE ION TRAP MASS-SPECTROMETER - PREREQUISITES
    MCLUCKEY, SA
    GLISH, GL
    VANBERKEL, GJ
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1991, 106 : 213 - 235
  • [33] EFFECTS OF COLLISIONAL COOLING ON ION DETECTION IN A QUADRUPOLE ION TRAP MASS-SPECTROMETER
    WU, HF
    BRODBELT, JS
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 115 (01): : 67 - 81
  • [34] DIELS-ALDER REACTIONS OF MASS-SELECTED IONS IN AN ION-TRAP MASS-SPECTROMETER
    SONI, M
    AMY, J
    FRANKEVICH, V
    COOKS, RG
    TAYLOR, D
    MCKEWAN, A
    SCHWARTZ, JC
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (10) : 911 - 915
  • [35] USING LASER TOMOGRAPHY TO INVESTIGATE THE RADIAL DISTRIBUTIONS OF MASS-SHIFTING COMPOUNDS IN AN ION-TRAP MASS-SPECTROMETER
    CLEVEN, CD
    COOKS, RG
    FINNIGAN, MAT
    GARRETT, AW
    HEMBERGER, PH
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 5 - ANYL
  • [36] AUTOMATION OF DATA-ACQUISITION AND PROCESSING INVOLVING DYNAMICALLY PROGRAMMED SCANNING FOR A QUADRUPOLE ION-TRAP MASS-SPECTROMETER
    CLARKE, NJ
    FRANKLIN, AM
    LANGFORD, ML
    PENMAN, AD
    THORNER, DA
    TODD, JFJ
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1995, 9 (09) : 723 - 730
  • [37] COUPLING OF AN ATMOSPHERIC-SAMPLING ION-SOURCE WITH AN ION-TRAP MASS-SPECTROMETER
    MCLUCKEY, SA
    GLISH, GL
    ASANO, KG
    ANALYTICA CHIMICA ACTA, 1989, 225 (01) : 25 - 35
  • [38] GEOPORPHYRIN ANALYSIS USING AN ION TRAP MASS-SPECTROMETER
    VANBERKEL, GJ
    GLISH, GL
    MCLUCKEY, SA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1989, 197 : 78 - PETR
  • [39] DYNAMIC TRAPPING OF LASER-GENERATED IONS IN AN ION-TRAP MASS-SPECTROMETER
    EIDEN, GC
    CISPER, ME
    ALEXANDER, ML
    HEMBERGER, PH
    NOGAR, NS
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1993, 206 : 82 - ANYL
  • [40] Direct trace analysis of metals and alloys in a quadrupole ion-trap mass spectrometer
    Song, K
    Hong, KH
    Yang, M
    Cha, H
    Lee, J
    Lee, GH
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 1999, 35 (03) : 217 - 221