THE SLEEVE DEVICE FUNCTIONS AS A STARLING RESISTOR TO RECORD SPHINCTER PRESSURE

被引:0
|
作者
LINEHAN, JH
DENT, J
DODDS, WJ
HOGAN, WJ
机构
[1] MED COLL WISCONSIN,DEPT RADIOL,MILWAUKEE,WI 53226
[2] MED COLL WISCONSIN,DEPT MED,MILWAUKEE,WI 53226
[3] MARQUETTE UNIV,DEPT BIOMED ENGN,MILWAUKEE,WI 53233
[4] FLINDERS UNIV S AUSTRALIA,MED CTR,DEPT MED,BEDFORD PK,SA 5042,AUSTRALIA
关键词
D O I
暂无
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
引用
收藏
页码:1165 / 1165
页数:1
相关论文
共 46 条
  • [31] Laparoscopic management of pathologic gastroesophageal reflux after sleeve gastrectomy using the magnetic sphincter augmentation (MSA) device-a Video Vignette
    Bona, Davide
    Zappa, Marco Antonio
    Panizzo, Valerio
    Sozzi, Andrea
    Lastraioli, Caterina
    Lombardo, Francesca
    Ogliari, Cristina
    Aiolfi, Alberto
    OBESITY SURGERY, 2022, 32 (05) : 1791 - 1793
  • [32] PULMONARY CAPILLARY WEDGE PRESSURE ESTIMATES OF LEFT-VENTRICULAR PRELOAD ARE INACCURATE IN ENDOTOXIN-SHOCK - CONTRIBUTION OF STARLING RESISTOR FORCES TO SEPTIC PULMONARY-HYPERTENSION
    KRAHMER, RL
    FANG, HK
    VITELLO, J
    RYPINS, EB
    LAW, WR
    SHOCK, 1994, 2 (05): : 344 - 350
  • [33] SLEEVE-SENSOR RECORDING OF LOWER ESOPHAGEAL SPHINCTER PRESSURE (LESP) IN YOUNG-CHILDREN WITH SYMPTOMATIC GASTROESOPHAGEAL REFLUX (GER)
    WERLIN, SL
    DODDS, WJ
    HOGAN, W
    PEDIATRIC RESEARCH, 1979, 13 (04) : 410 - 410
  • [34] The Effect of Laparoscopic Vertical Sleeve Gastrectomy on Lower Esophageal Sphincter Pressure, Lower Esophageal Sphincter Length and GERD Using Functional Esophageal Test: A Systematic Review and Meta-Analysis
    Memon, Muhammed A.
    Yunus, Rossita M.
    Alam, Khorshed
    Hoque, Zahirul
    Khan, Shahjahan
    JOURNAL OF THE AMERICAN COLLEGE OF SURGEONS, 2024, 239 (05) : S33 - S34
  • [35] INTRODUCTION TO THE NEW AROYO® ARTIFICIAL URINARY SPHINCTER AND THE RELATIONSHIP OF ADJUSTABLE AND QUANTIFIABLE DEVICE PRESSURE TO PAD WEIGHT REDUCTION
    Zachoval, R.
    Haillot, O.
    Krhut, J.
    Thiruchelvam, N.
    Chlosta, P.
    Lynch, W.
    Moon, D.
    Chin, P.
    LeNormand, L.
    Hansen, F.
    Cornu, J.
    Oelke, M.
    NEUROUROLOGY AND URODYNAMICS, 2016, 35 : S215 - S217
  • [36] Predictors of Device-Related Complications After Exchange of the Pressure Regulating Balloon in Men with an Artificial Urinary Sphincter
    Baron, Maximilien
    Auble, Annabelle
    Cornu, Jean-Nicolas
    UROLOGY, 2020, 136 : 278 - 278
  • [37] Predictors of Device-Related Complications After Exchange of the Pressure Regulating Balloon in Men with an Artificial Urinary Sphincter Response
    Loh-Doyle, Jeffrey
    UROLOGY, 2020, 136 : 278 - 278
  • [38] Predictors of Device-related Complications After Exchange of the Pressure-regulating Balloon in Men With an Artificial Urinary Sphincter
    Loh-Doyle, Jeffrey C.
    Nazemi, Azadeh
    Ashrafi, Akbar
    Doumanian, Leo R.
    Ginsberg, David A.
    Boyd, Stuart D.
    UROLOGY, 2020, 135 : 154 - 158
  • [39] High-resolution esophageal pressure topography is superior to conventional sleeve manometry for the detection of transient lower esophageal sphincter relaxations associated with a reflux event
    Rohof, W. O. A.
    Boeckxstaens, G. E. E.
    Hirsch, D. P.
    NEUROGASTROENTEROLOGY AND MOTILITY, 2011, 23 (05): : 427 - e173
  • [40] PROSPECTIVE 3-MONTH EVALUATION OF THE UPPER ESOPHAGEAL SPHINCTER (UES) ASSIST DEVICE ON BOTH REFLUX SYMPTOMS AND INTRALUMINAL UES PRESSURE
    Siwiec, Robert M.
    Silvers, Stacey L.
    Miller, James S.
    GASTROENTEROLOGY, 2017, 152 (05) : S240 - S240