Calculations for AP1000 nuclear power plant SGTR accident based on RELAP5/mod 3.3 program

被引:0
|
作者
Jia, Bin [1 ]
Jing, Jianping [1 ]
Qiao, Xuedong [1 ]
Zhang, Chunming [1 ]
机构
[1] Nucl & Radiat Safety Ctr, Beijing 100082, Peoples R China
关键词
RELAP5; AP1000; SGTR; SNAP;
D O I
10.3233/JCM-150522
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
AP1000 nuclear power plant model is founded via RELAP5/mod 3.3 program in detail. Refer to SGTR accident basic assumptions in the safety analysis report, calculations for AP1000 nuclear power plant SGTR accident are carried out. And through comparison between the result got and the result from safety analysis report calculated by LOFTTR2 program, the two results are very consistent. It's found that even if the operators do not interfere, AP1000 nuclear power plant protection systems and passive design measures will trigger an automatic response measures, it can terminate the SG heat transfer tube leaking and make RCS be stable in a safe condition and to prevent SG overflowing and ADS actions occurring.
引用
收藏
页码:81 / 90
页数:10
相关论文
共 50 条
  • [21] A SIMULATION OF SMALL BREAK LOSS OF COOLANT ACCIDENT (SB-LOCA) IN AP1000 NUCLEAR POWER PLANT USING RELAP5-MV
    Yousif, Eltayeb
    Zhang Zhijian
    Tian Zhao-fei
    Mustafa, A. M.
    [J]. PROCEEDINGS OF THE 25TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING, 2017, VOL 5, 2017,
  • [22] Simulation of loss-of-flow transient in a VVER-1000 nuclear power plant with RELAP5/MOD3.2
    Grudev, P
    Pavlova, M
    [J]. PROGRESS IN NUCLEAR ENERGY, 2004, 45 (01) : 1 - 10
  • [23] RELAP5/SCDAPSIM model development for AP1000 and verification for large break LOCA
    Trivedi, A. K.
    Allison, C.
    Khanna, A.
    Munshi, P.
    [J]. NUCLEAR ENGINEERING AND DESIGN, 2016, 305 : 222 - 229
  • [24] Long-Term Station Blackout Accident Analyses of a PWR with RELAP5/MOD3.3
    Prosek, Andrej
    Cizelj, Leon
    [J]. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2013, 2013
  • [25] The Investigation of Nonavailability of Passive Safety Systems Effects on Small Break LOCA Sequence in AP1000 Using RELAP5 MOD 4.0
    Hussain, Anwar
    Nawaz, Amjad
    [J]. SCIENCE AND TECHNOLOGY OF NUCLEAR INSTALLATIONS, 2016, 2016
  • [26] APPLICATION OF RELAP5 MOD2 TO LOVIISA NUCLEAR-POWER-PLANT OVERCOOLING TRANSIENTS
    KANTEE, H
    TUOMISTO, H
    YRJOLA, V
    [J]. NUCLEAR TECHNOLOGY, 1990, 90 (03) : 308 - 315
  • [27] TRANSIENT ANALYSIS IN THE ASCO NUCLEAR-POWER-PLANT USING RELAP5 MOD2
    REVENTOS, F
    SANCHEZBAPTISTA, J
    NAVAS, AP
    [J]. NUCLEAR TECHNOLOGY, 1990, 90 (03) : 294 - 307
  • [28] 基于RELAP5程序的AP1000典型事故瞬态特性研究
    靖剑平
    乔雪冬
    贾斌
    庄少欣
    孙微
    张春明
    [J]. 原子能科学技术, 2015, 49 (04) : 646 - 653
  • [29] Transient characteristics of main feedwater line rupture accident for AP1000 nuclear power plant
    Jia X.
    An J.-R.
    Jing J.-P.
    [J]. Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2016, 50 (08): : 1422 - 1427
  • [30] Modeling by RELAP5 in nuclear power plant engineering simulator
    [J]. Lin, M., 2005, Atomic Energy Publishing House (39):