MAGNETIZATION-TRANSFER CONTRAST ON GRADIENT-ECHO MR-IMAGING OF TEMPOROMANDIBULAR-JOINT

被引:0
|
作者
NIITSU, M
HIROHATA, H
YOSHIOKA, H
ANNO, I
CAMPEAU, NG
ITAI, Y
机构
[1] UNIV TSUKUBA,INST CLIN MED,DEPT ORAL & MAXILLOFACIAL SURG,TSUKUBA,IBARAKI 305,JAPAN
[2] MAYO CLIN & MAYO FDN,DEPT DIAGNOST RADIOL,MAGNET RESONANCE LAB,ROCHESTER,MN
关键词
TEMPOROMANDIBULAR JOINT; MAGNETIC RESONANCE (MR); MR; MAGNETIZATION TRANSFER CONTRAST;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Thirty-nine temporomandibular joints (TMJ) from 20 patients with suspected internal derangements were imaged by a 1.5 T MR imager. The on-resonance binomial magnetization transfer contrast (MTC) pulse was applied to gradient echo images with a dual receiver coil (9 s/section). With the use of an opening device, a series of sequential images were obtained at increments of mouth opening and closing. The tissue signal intensities with (Ms) and without (Mo) MTC were measured and subjective image analysis was performed. Compared with the standard images, MTC technique provided selective signal suppression of disks. The average of Ms/Mo ratio of the disks (0.56) was lower than that of the retrodiskal pad (0.79) and of the effusion (0.89). With MTC technique, fluid conspicuity was superior to standard image. However, no significant superiority was found in disk definition subjectively.
引用
收藏
页码:295 / 299
页数:5
相关论文
共 50 条
  • [41] MR-IMAGING OF THE KNEE IN THE SAGITTAL PROJECTION - COMPARISON OF 3-DIMENSIONAL GRADIENT-ECHO AND SPIN-ECHO SEQUENCES
    REEDER, JD
    MATZ, SO
    BECKER, L
    ANDELMAN, SM
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (03) : 537 - 540
  • [42] MAGNETIZATION PREPARED RAPID GRADIENT-ECHO (MP-RAGE) MR IMAGING OF THE LIVER - COMPARISON WITH SPIN-ECHO IMAGING
    DELANGE, EE
    MUGLER, JP
    BERTOLINA, JA
    GAY, SB
    JANUS, CL
    BROOKEMAN, JR
    MAGNETIC RESONANCE IMAGING, 1991, 9 (04) : 469 - 476
  • [43] Temporomandibular joint MRI: A 2-D gradient-echo technique
    Roditi, GH
    Duncan, KA
    Needham, G
    Redpath, TW
    CLINICAL RADIOLOGY, 1997, 52 (06) : 441 - 444
  • [44] FATTY METAMORPHOSIS OF HEPATOCELLULAR-CARCINOMA DETECTION WITH CHEMICAL-SHIFT GRADIENT-ECHO MR-IMAGING
    MARTIN, J
    SENTIS, M
    ZIDAN, A
    DONOSO, L
    PUIG, J
    FALCO, J
    BELLA, R
    RADIOLOGY, 1995, 195 (01) : 125 - 130
  • [45] FAST MR-IMAGING - 1ST CLINICAL-RESULTS WITH THE NEW GRADIENT-ECHO SEQUENCE
    WEISS, T
    MITSCH, E
    LANIADO, M
    SANDER, B
    KORNMESSER, W
    DEIMLING, M
    FELIX, R
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1987, 146 (02): : 214 - 222
  • [46] Generalized equation for describing the magnetization in spoiled gradient-echo imaging
    Murase, Kenya
    MAGNETIC RESONANCE IMAGING, 2011, 29 (05) : 723 - 730
  • [47] MAGNETIZATION TRANSFER EFFECTS IN MULTISLICE MR-IMAGING
    SANTYR, GE
    MAGNETIC RESONANCE IMAGING, 1993, 11 (04) : 521 - 532
  • [48] MR IMAGING OF THE TEMPOROMANDIBULAR-JOINT AT 0.3T
    WESTESSON, PL
    HANSSON, LG
    WESTESSON, PL
    KATZBERG, RW
    TALLENTS, RH
    KURITA, K
    HOLTAS, S
    SVENSSON, SA
    ERIKSSON, L
    JOHANSEN, CC
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (06) : 1316 - 1316
  • [49] MR TOMOGRAPHY OF THE TEMPOROMANDIBULAR-JOINT USING T1-WEIGHTED MULTISLICE GRADIENT ECHO SEQUENCES
    DEWES, W
    KRAHE, T
    LUCKERATH, W
    GIESEKE, J
    FORTSCHRITTE AUF DEM GEBIETE DER RONTGENSTRAHLEN UND DER NUKLEARMEDIZIN, 1988, 148 (05): : 541 - 544
  • [50] MUSCULOSKELETAL MR-IMAGING - TURBO (FAST) SPIN-ECHO VERSUS CONVENTIONAL SPIN-ECHO AND GRADIENT-ECHO IMAGING AT 0.5-TESLA
    VAHLENSIECK, M
    LANG, P
    SEELOS, K
    SZE, DYH
    GRAMPP, S
    REISER, M
    SKELETAL RADIOLOGY, 1994, 23 (08) : 607 - 610