High-resolution geomagnetic observation system using HTS-SQUID

被引:2
|
作者
Katori, Yuta [1 ]
Isogami, Shinji [2 ]
Hato, Tsunehiro [3 ]
Tsukamoto, Akira [3 ]
Tanabe, Keiichi [3 ]
Ohnishi, Nobuhito [4 ]
Furukawa, Chikara [4 ]
Okubo, Kan [1 ]
机构
[1] Tokyo Metropolitan Univ, Grad Sch Syst Design, 6-6 Asahigaoka, Hino, Tokyo 1910065, Japan
[2] Natl Inst Mat Sci, Res Ctr Magnet & Spintron Mat, 1-2-1 Sengen, Tsukuba, Ibaraki 3050047, Japan
[3] Superconducting Sensing Technol Res Assoc, Kohoku Ku, 2-11-19 Minowa Cho, Yokohama, Kanagawa 2230051, Japan
[4] TIERRA TECN Ltd, 3-25-1 Enoki, Musashimurayama, Tokyo 2080022, Japan
来源
IEICE COMMUNICATIONS EXPRESS | 2018年 / 7卷 / 03期
关键词
HTS-SQUID; magnetometer; geomagnetic observation; high-resolution;
D O I
10.1587/comex.2017XBL0168
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Our research group reported successful observation of "co-faulting" Earth's magnetic field changes because of piezomagnetic effects caused by earthquake tremors during the 2008 Iwate-Miyagi Nairiku earthquake of M7.2 using a geomagnetic observation system with flux-gate magnetometers. This is an important finding: electromagnetic fields propagate from a source to an observation site at the light speed in the crustal materials. Further earthquake detection efforts can lead us to a new system for super-early warning of earthquake detection with the geomagnetic signal. However, the observed result with the earthquake was suggested that the geomagnetic field change accompanying fault movement, whose sources are the piezomagnetic effects, is very small and short term. Therefore, to develop an extremely important high-resolution magnetometer system, we first conducted long-term precise geomagnetic observations using a high-temperature superconductor based superconducting quantum-interference device (HTS-SQUID) magnetometer system. The HTS-SQUID magnetometer system had never been used for high-resolution geomagnetic observations outdoors. Since March 2012, we have observed geomagnetic field using the HTS-SQUID magnetometer at Iwaki observation site (IWK) in Fukushima, Japan. Comparison between the introduced HTS-SQUID magnetometer and conventional flux-gate clarified that the HTS-SQUID magnetometer in our system has higher resolution of magnetic field observation.
引用
收藏
页码:71 / 76
页数:6
相关论文
共 50 条
  • [31] Ultra-Low Field MRI Food Inspection System Using HTS-SQUID with Flux Transformer
    Tanaka, Saburo
    Kawagoe, Satoshi
    Demachi, Kazuma
    Hatta, Junichi
    IEICE TRANSACTIONS ON ELECTRONICS, 2018, E101C (08): : 680 - 684
  • [32] Development of a Compact Magnetometer with an AC/DC Magnetic Field Using HTS-SQUID
    Takagi, Ryuki
    Saari, Mohd Mawardi
    Sakai, Kenji
    Kiwa, Toshihiko
    Tsukada, Keiji
    2013 IEEE 14TH INTERNATIONAL SUPERCONDUCTIVE ELECTRONICS CONFERENCE (ISEC), 2013,
  • [33] Development of non-destructive evaluation system using an HTS-SQUID gradiometer with an external pickup coil
    Kawano, J.
    Kawauchi, S.
    Ishikawa, F.
    Tanabe, K.
    PROCEEDINGS OF THE 27TH INTERNATIONAL SYMPOSIUM ON SUPERCONDUCTIVITY (ISS 2014), 2015, 65 : 193 - 196
  • [34] Detection of wire element breakage in power transmission line using HTS-SQUID
    Miyazaki, A.
    Hatsukade, Y.
    Matsuura, H.
    Maeda, T.
    Suzuki, A.
    Tanaka, S.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2009, 469 (15-20): : 1643 - 1648
  • [35] Design and Fabrication of HTS-SQUID Gradiometer With Imbalance of 10-4 Using a Gradiometric SQUID Structure
    Tsukamoto, Akira
    Adachi, Seiji
    Hato, Tsunehiro
    Oshikubo, Yasuo
    Tanabe, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2022, 32 (03)
  • [36] Development of HTS-SQUID System for a Monitoring System of CO2 Enhanced Oil Recovery
    Hato, Tsunehiro
    Tsukamoto, Akira
    Adachi, Seiji
    Oshikubo, Yasuo
    Watanabe, Hidehisa
    Ishikawa, Hidehiro
    Okada, Chikara
    Kato, Ayato
    Harada, Makoto
    Yoshimatsu, Keita
    Kunishi, Yousuke
    Tanabe, Keiichi
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2017, 27 (04)
  • [37] Aggregation of Magnetic Nanoparticles in Biological Solvents Evaluated by HTS-SQUID Magnetic Immunoassay System
    Yamashita, K.
    Kishimoto, K.
    Kuroda, H.
    Wang, J.
    Sakai, K.
    Saari, M. M.
    Kiwa, T.
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2023, 33 (05)
  • [38] Development of Robust HTS-SQUID for Non-destructive Inspection System in Unshielded Environment
    Yoshida, K.
    Kage, T.
    Suzuki, T.
    Hatsukade, Y.
    Tanaka, S.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [39] Mobile NDE System Utilizing Robust HTS-SQUID Magnetometer for Use in Unshielded Environments
    Hatsukade, Yoshimi
    Tanaka, Saburo
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (03)
  • [40] Post Filtering Technique for High-Resolution Magnetic Image of an HTS Scanning SQUID Microscope
    Ishikawa, T.
    Hayashi, T.
    Wang, H. W.
    Itozaki, H.
    Kawabe, U.