A SMALL, BATTERY-OPERATED FLUOROSCOPIC SYSTEM - LIXISCOPE WITH X-RAY GENERATOR

被引:0
|
作者
YIN, LI
TROMBKA, JI
RUITBERG, AP
SELTZER, SM
机构
[1] UNIV MARYLAND, DEPT CHEM, COLLEGE PK, MD 20742 USA
[2] NASA, GODDARD SPACE FLIGHT CTR, SPACE POWER APPLICAT BRANCH, GREENBELT, MD 20771 USA
[3] NBS, CTR RADIAT RES, DIV RADIAT PHYS, RADIAT THEORY GRP, WASHINGTON, DC USA
关键词
IMAGING TECHNIQUES - MATERIALS TESTING - Nondestructive Examination - OPTICAL INSTRUMENTS;
D O I
暂无
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
A small, battery-operated x-ray generator has been developed to be used as part of a small-format fluoroscopic system, the Lixiscope (Low Intensity X-ray Imaging Scope). The x-ray generator consists of a grounded rod-anode x-ray tube with a 0. 2 mm focal spot and a specially designed, battery-operated, 0 to minus 80 kv voltage supply. Total power consumption is about 10 w. The complete fluoroscopic system is described, and some examples of possible applications are shown.
引用
收藏
页码:844 / 848
页数:5
相关论文
共 50 条
  • [31] PYROELECTRIC X-RAY GENERATOR
    BROWNRIDGE, JD
    NATURE, 1992, 358 (6384) : 287 - 288
  • [32] PULSED X-RAY GENERATOR
    JACK, JW
    SMITH, T
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1973, 6 (02): : 162 - 164
  • [33] X-RAY PULSE GENERATOR
    GRIGOREV, VA
    OBODOVSK.IM
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (01): : 204 - &
  • [34] X-ray beam tracking system for a fluoroscopic C-arm unit
    Dinu, PM
    Bednarek, DR
    Wobschall, D
    Peterson, R
    Ionita, C
    Rudin, S
    Zeng, M
    Chugh, K
    Hoffmann, KR
    MEDICAL PHYSICS, 2003, 30 (06) : 1424 - 1424
  • [35] Soft x-ray emission form a small plasma focus operated in deuterium
    Serban, A
    Lee, S
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 1997, 6 (01): : 78 - 85
  • [36] Soft X-ray yield measurement in a small plasma focus operated in neon
    Liu, MH
    Feng, XP
    Springham, SV
    Lee, S
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 1998, 26 (02) : 135 - 140
  • [37] Portable x-ray fluorescence spectrometer with a pyroelectric x-ray generator
    Ida, H
    Kawai, J
    X-RAY SPECTROMETRY, 2005, 34 (03) : 225 - 229
  • [38] Development of a powerful X-ray generator with a small spot-size option at ISAS X-ray beamline facility
    Suzuki, Hitomi
    Maeda, Yoshitomo
    Ishida, Manabu
    Nakaniwa, Nozomi
    Nakatsubo, Shunichi
    Ohashi, Takaya
    Takeo, Mai
    SPACE TELESCOPES AND INSTRUMENTATION 2020: ULTRAVIOLET TO GAMMA RAY, 2021, 11444
  • [39] REQUIREMENTS IN DESIGN OF AN X-RAY TABLE FOR FLUOROSCOPIC EXAMINATIONS
    BERRIDGE, FR
    BRITISH JOURNAL OF RADIOLOGY, 1971, 44 (518): : 150 - &
  • [40] Novel method for correction of x-ray fluoroscopic image
    Zhang, W. Q.
    Dai, K. R.
    Wang, C. T.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 6340 - 6343