MR-IMAGING OF DISEASES OF THE BRAIN - COMPARISON OF CEASE AND CONVENTIONAL SPIN-ECHO T2-WEIGHTED PULSE SEQUENCES

被引:18
|
作者
PATEL, MR [1 ]
KLUFAS, RA [1 ]
SHAPIRO, AW [1 ]
机构
[1] BRIGHAM & WOMENS HOSP,DEPT RADIOL,BOSTON,MA 02115
关键词
D O I
10.2214/ajr.165.4.7677002
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to compare a combined gradient and spin-echo (GRASE) technique, which is a rapid T2-weighted imaging sequence, with conventional spin-echo (SE) sequences for imaging brain lesions. The GRASE sequences would allow increased patient throughput with potential cost savings and be useful in uncooperative patients without requiring echoplanar imaging techniques and specialized hardware. SUBJECTS AND METHODS. Conventional SE and GRASE T2-weighted images of 49 consecutive patients (20-86 years old) were reviewed independently by three neurora-diologists for the presence and characterization of lesions (most of which were nonspecific foci of hyperintensity within the white matter), gray-white matter differentiation, conspicuity of lesions, and periventricular signal abnormality. The MR studies were performed on a 1.0-T Siemens Magnetom Impact scanner, with the SE images obtained using a TRI TE of 2400/40 and the GRASE images obtained using a TR/effective TE of 4400/110. RESULTS. The number of lesions detected that were 5 mm or larger in maximal diameter did not significantly differ among techniques. For lesions smaller than 5 mm, conventional SE T2-weighted images showed more lesions (p < .01). The SE images were better than the GRASE images for assessing gray-white matter differentiation, conspicuity of lesions, and periventricular signal abnormality, The two hypointense lesions were better assessed on the conventional SE images. CONCLUSION. Although GRASE imaging may be potentially useful for rapid imaging of the brain, our experience shows it has a markedly diminished sensitivity for detecting lesions smaller than 5 mm in diameter. Currently, GRASE imaging should not replace the routine clinical use of conventional SE sequences.
引用
收藏
页码:963 / 966
页数:4
相关论文
共 50 条
  • [21] MR MYELOGRAPHY USING HEAVILY T2-WEIGHTED FAST SPIN-ECHO PULSE SEQUENCES WITH FAT PRESATURATION
    KRUDY, AG
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1992, 159 (06) : 1315 - 1320
  • [22] COMPARISON OF GRADIENT-RECALLED-ECHO AND T2-WEIGHTED SPIN-ECHO PULSE SEQUENCES IN INTRAMEDULLARY SPINAL LESIONS
    KATZ, BH
    QUENCER, RM
    HINKS, RS
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1989, 10 (04) : 815 - 822
  • [23] T2-weighted MR imaging of the liver: Qualitative and quantitative comparison of SPACE MR imaging with turbo spin-echo MR imaging
    Dohan, Anthony
    Gavini, Jean-Philippe
    Place, Vinciane
    Sebbag, Delphine
    Vignaud, Alexandre
    Herbin, Christine
    Hamzi, Lounis
    Boudiaf, Mourad
    Soyer, Philippe
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (11) : E655 - E661
  • [24] MR imaging of diseases of the brain: Comparison of HASTE and Turbo-SE T2-weighted pulse sequences
    Patel, M
    Klufas, RA
    Alberico, RA
    RADIOLOGY, 1996, 201 : 983 - 983
  • [25] MR-IMAGING OF HEAD AND NECK TUMORS - COMPARISON OF T1-WEIGHTED CONTRAST-ENHANCED FAT-SUPPRESSED IMAGES WITH CONVENTIONAL T2-WEIGHTED AND FAST SPIN-ECHO T2-WEIGHTED IMAGES
    ROSS, MR
    SCHOMER, DF
    CHAPPELL, P
    ENZMANN, DR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1994, 163 (01) : 173 - 178
  • [26] Liver MR imaging: Comparison of respiratory triggered fast spin echo with T2-weighted spin-echo and inversion recovery
    Keogan, MT
    Spritzer, CE
    Paulson, EK
    Paine, SS
    Harris, L
    Dahlke, JL
    MacFall, JR
    ABDOMINAL IMAGING, 1996, 21 (05): : 433 - 439
  • [27] CONTRAST ON T2-WEIGHTED IMAGES OF THE LUMBAR SPINE USING FAST SPIN-ECHO AND GATED CONVENTIONAL SPIN-ECHO SEQUENCES
    CHAPPELL, PM
    GLOVER, GH
    ENZMANN, DR
    NEURORADIOLOGY, 1995, 37 (03) : 183 - 186
  • [28] T2-weighted MRI for the assessment of joint effusion: Comparative study of conventional spin-echo and fast spin-echo sequences
    Mori, S
    Kaneda, T
    Lee, K
    Kato, M
    Motohashi, J
    Ogura, I
    ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 2004, 97 (06): : 768 - 774
  • [29] Multi-shot echo-planar Flair imaging of brain tumors: comparison of spin-echo T1-weighted, fast spin-echo T2-weighted, and fast spin-echo Flair imaging
    Tomura, N
    Kato, K
    Takahashi, S
    Sashi, R
    Izumi, J
    Narita, K
    Watarai, J
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2002, 26 (02) : 65 - 72
  • [30] CONVENTIONAL AND FAST SPIN-ECHO MR-IMAGING - MINIMIZING ECHO TIME
    VINITSKI, S
    MITCHELL, DG
    EINSTEIN, SG
    RAO, VM
    FLANDERS, AE
    SCHWEITZER, ME
    LISTERUD, J
    SCHNALL, MD
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1993, 3 (03): : 501 - 507