Blood pressure measurement in pregnancy: the effect of arm circumference and sphygmomanometer cuff size

被引:9
|
作者
Kho, Chye L.
Brown, Mark A.
Ong, Sharon L. H.
Mangos, George J. [1 ]
机构
[1] Univ New South Wales, St George Clin Sch, Dept Med, Kogarah, NSW 2217, Australia
关键词
blood pressure measurement; pregnancy; cuff size; arm circumference;
D O I
10.1258/om.2009.090017
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
This study aimed to assess the difference in blood pressure readings between the standard and large cuff and to determine if such a difference applies over a range of arm circumferences (ACs) in pregnancy. We measured blood pressure on 219 antenatal women. Six blood pressure readings were taken, three with a standard 'adult' and three with a 'large' cuff, in random order. A random zero sphygmomanometer was used by a trained observer. Women with an AC >33 cm were similar in age, gestational age and parity but were heavier and had more hypertension than those with AC <= 33 cm. There was a systematic difference between the standard and large cuff of 5-7 mmHg with little effect due to AC. We were unable to demonstrate an association between the standard and large cuff blood pressure difference and increasing blood pressure. Our study has shown that both systolic and diastolic blood pressure measurements are more dependent on the cuff size used than AC and for the individual it is difficult to predict the magnitude of effect the different cuff sizes will have on blood pressure measurements. This study has shown the presence of an average difference in blood pressure measurement between standard and large cuffs in pregnancy, and does not support the arbitrary 33 cm 'cut-off' recommended in guidelines for the use of a large cuff in pregnancy.
引用
收藏
页码:116 / 120
页数:5
相关论文
共 50 条
  • [21] Pitfalls of Cuff Size and Blood Pressure Measurement
    Gallagher, Benjamin D.
    Bryant, Kelsey B.
    Cluett, Jennifer L.
    JAMA INTERNAL MEDICINE, 2024, 184 (04) : 448 - 449
  • [22] The influence of cuff size on blood pressure measurement
    C Bakx
    G Oerlemans
    H van den Hoogen
    C van Weel
    T Thien
    Journal of Human Hypertension, 1997, 11 : 439 - 445
  • [23] AN ADJUSTABLE BLOOD PRESSURE CUFF TO CORRECT ERRORS DUE TO VARIATIONS IN ARM CIRCUMFERENCE
    DASBERG, H
    BLONDHEIM, SH
    SADOVSKY, E
    BRITISH HEART JOURNAL, 1962, 24 (02): : 214 - &
  • [24] EFFECT OF SIZE OF CUFF BLADDER ON ACCURACY OF MEASUREMENT OF INDIRECT BLOOD PRESSURE
    SIMPSON, JA
    JAMIESON, G
    DICKHAUS, DW
    GROVER, RF
    AMERICAN HEART JOURNAL, 1965, 70 (02) : 208 - &
  • [25] Influence of Age on Upper Arm Cuff Blood Pressure Measurement
    Picone, Dean S.
    Schultz, Martin G.
    Otahal, Petr
    Black, J. Andrew
    Bos, Willem J.
    Chen, Chen-Huan
    Cheng, Hao-Min
    Cremer, Antoine
    Dwyer, Nathan
    Fonseca, Ricardo
    Hughes, Alun D.
    Kim, Hack-Lyoung
    Lacy, Peter S.
    Laugesen, Esben
    Ohte, Nobuyuki
    Omboni, Stefano
    Ott, Christian
    Pereira, Telmo
    Pucci, Giacomo
    Roberts-Thomson, Philip
    Rossen, Niklas B.
    Schmieder, Roland E.
    Sueta, Daisuke
    Takazawa, Kenji
    Wang, Jiguang
    Weber, Thomas
    Westerhof, Berend E.
    Williams, Bryan
    Yamada, Hirotsugu
    Yamamoto, Eiichiro
    Sharman, James E.
    HYPERTENSION, 2020, 75 (03) : 844 - 850
  • [26] SHOULD BLOOD PRESSURE MEASUREMENT BE PERFORMED WITH THE CUFF ON A BARE ARM?
    Keltjens, E. B. M.
    Deinum, J.
    Lenders, J. W. M.
    Thien, Th.
    JOURNAL OF HYPERTENSION, 2009, 27 : S3 - S4
  • [27] WHICH CUFF SIZE FOR BLOOD-PRESSURE MEASUREMENT
    VERDON, F
    SCHWEIZERISCHE MEDIZINISCHE WOCHENSCHRIFT, 1992, 122 (40) : 1491 - 1496
  • [28] SPHYGMOMANOMETER CUFF CALIBRATED FOR CORRECTED BLOOD-PRESSURE READINGS
    HIGHAM, S
    BRITISH MEDICAL JOURNAL, 1959, 1 (APR4): : 906 - 906
  • [29] Evaluation of blood pressure cuff positioning for the aneroid sphygmomanometer.
    Tsai, K
    Chung, J
    Gerkin, R
    Desser, KB
    Jasser, MK
    JOURNAL OF INVESTIGATIVE MEDICINE, 2004, 52 (01) : S170 - S170
  • [30] The impact of sphygmomanometer placement and cuff placement on blood pressure measurements
    Zhu, Xiao-Yong
    Zhang, Pu-Hua
    Huang, Wen-Yin
    Huang, Wan
    Tang, Xin-Hu
    Yu, Hua
    Wang, Su-Nan
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11