COMPARISON OF THERMOCOAGULATION EFFECTS OF LOW-POWER, SLOW HEATING VERSUS HIGH-POWER, RAPID HEATING ND-YAG LASER REGIMENS IN A CANINE PROSTATE MODEL

被引:16
|
作者
ORIHUELA, E [1 ]
MOTAMEDI, M [1 ]
CAMMACK, T [1 ]
TORRES, JH [1 ]
POWSANG, M [1 ]
LAHAYE, M [1 ]
COWAN, DF [1 ]
WARREN, MM [1 ]
机构
[1] UNIV TEXAS,MED BRANCH,DEPT PATHOL,GALVESTON,TX 77555
来源
JOURNAL OF UROLOGY | 1995年 / 153卷 / 01期
关键词
PROSTATE; PROSTATIC HYPERTROPHY; LASER SURGERY;
D O I
10.1097/00005392-199501000-00076
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
We compared the thermocoagulation effects of low power, slow heating (15 W X 180 seconds) versus high power, rapid heating (50 W X 60 seconds) laser regimens in the canine prostate. The study was performed in 20 mongrel canines. On each prostate, the low power regimen was delivered at the 2 and 4 o'clock positions, and the high power at the 8 and 10 o'clock positions. The laser power was measured at the fiber tip. Seven dogs (acute group) were sacrificed 1 hour after the procedure. The other 13 dogs (chronic group) were sacrificed at different time intervals from 3 days to 9 weeks after the procedure. The average depth of coagulation was significantly greater in lesions treated at low power (acute: 10.7 mm., chronic: 13.3 mm.) than in those treated at high power (acute: 8.5 mm., chronic: 11.6 mm.). Another potential benefit of the low power regimen observed in the study was preservation of the integrity and efficiency of the laser probe.
引用
收藏
页码:196 / 200
页数:5
相关论文
共 50 条
  • [31] HIGH-POWER DIODE-ARRAY-PUMPED FREQUENCY-DOUBLED CW ND-YAG LASER
    BURNHAM, R
    HAYS, AD
    OPTICS LETTERS, 1989, 14 (01) : 27 - 29
  • [32] HIGH-POWER SINGLE-FREQUENCY LASER AT 1.32 MU-M USING ND-YAG
    COTTER, D
    OPTICS COMMUNICATIONS, 1982, 43 (03) : 200 - 202
  • [33] GENERATION OF HIGH-POWER NANOSECOND PULSES FROM LASER DIODE-PUMPED ND-YAG LASERS
    CHAN, K
    APPLIED OPTICS, 1988, 27 (07): : 1227 - 1230
  • [34] Comparative study of low-power versus high-power holmium laser enucleation of the prostate for large volume benign prostatic hyperplasia
    Du, Renji
    Wang, Ping
    Gao, Zhixiang
    Liu, Haiyong
    Sun, Zhiwei
    Gu, Lijuan
    Ding, Yue
    Wang, Rong
    LASERS IN MEDICAL SCIENCE, 2025, 40 (01)
  • [35] BARE FIBER LOW-POWER ND-YAG LASER INTERSTITIAL HYPERTHERMIA - COMPARISON BETWEEN DIFFUSER TIP AND NONMODIFIED TIP - AN INVITRO STUDY
    NOLSOE, C
    TORPPEDERSEN, S
    OLLDAG, E
    HOLM, HH
    LASERS IN MEDICAL SCIENCE, 1992, 7 (01) : 1 - 7
  • [36] Duty cycle and modulation effects in aluminium alloy welding with high power Nd-YAG laser
    Kathuria, YP
    Tsuboi, A
    HIGH-POWER LASERS: APPLICATIONS AND EMERGING APPLICATIONS, 1996, 2789 : 21 - 27
  • [37] HIGH-POWER, CW SINGLE-FREQUENCY, TEM00, DIODE-LASER-PUMPED ND-YAG LASER
    WALLMEROTH, K
    PEUSER, P
    ELECTRONICS LETTERS, 1988, 24 (17) : 1086 - 1088
  • [38] A HIGH-POWER SUBPICOSECOND DISTRIBUTED FEEDBACK DYE-LASER SYSTEM PUMPED BY A MODE-LOCKED ND-YAG LASER
    RAKSI, F
    HEUER, W
    ZACHARIAS, H
    APPLIED PHYSICS B-PHOTOPHYSICS AND LASER CHEMISTRY, 1991, 53 (02): : 97 - 100
  • [39] Low-Power Vs High-Power Holmium Laser Enucleation of the Prostate: Critical Assessment through Randomized Trial
    Elshal, Ahmed M.
    El-Nahas, Ahmed R.
    Ghazy, Mostafa
    Nabeeh, Hossam
    Laymon, Mahmoud
    Satan, Mohamed
    Ghobrial, Fady K.
    El-Kappany, Hamdy A.
    UROLOGY, 2018, 121 : 58 - 65
  • [40] COMPARISON OF HIGH-POWER AND LOW-POWER ARGON-LASER PHOTOCOAGULATION USING AN ANIMAL-MODEL OF ACUTE BLEEDING ULCER
    SILVERSTEIN, F
    PROTELL, R
    AUTH, D
    DENNIS, M
    PIERCEY, J
    RUBIN, C