ESTIMATION OF NORMAL LUMBAR FLEXION WITH SURFACE INCLINOMETRY - A COMPARISON OF 3 METHODS

被引:37
|
作者
RONDINELLI, R
MURPHY, J
ESLER, A
MARCIANO, T
CHOLMAKJIAN, C
机构
[1] UNIV COLORADO,SCH MED,DEPT PREVENT MED & BIOMETR,DENVER,CO 80202
[2] SACRED HEART HOSP & HLTH CTR,HANFORD,CA
[3] ASSOCIATED HLTH FOCUS,SALINAS,CA
关键词
INTRARATER RELIABILITY; INTERRATER RELIABILITY; INCLINOMETRY; LUMBAR SPINAL FLEXION; IMPAIRMENT DETERMINATION;
D O I
10.1097/00002060-199208000-00004
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
The purpose of this study was to determine the magnitude and clinical significance of surface measurement error in the determination of lumbar spinal flexion. Intrarater, inter-rater and intermethod reliability estimates were obtained using single inclinometry, double inclinometry and back range-of-motion inclinometry methods. Eight healthy subjects were examined independently by two experienced observers and three replicates of each measurement were obtained by each observer in a random sequence. In addition, three replicates of lumbar flexion angles were obtained for each subject by a single observer using the B-200. Reliability estimates were determined by intraclass correlation coefficients and were further compared by paired t tests between observation series. The median range of error was 8.5-degrees using the single inclinometer, 10.5-degrees using the double inclinometer and 16' using the back range-of-motion. The intrarater reliability was generally higher than inter-rater reliability and intermethod reliability was low in most cases reflecting the poor cross-validity across inclinometry methods and between each inclinometry method and the B-200. In conclusion, significant measurement error in estimating lumbar flexion by inclinometry may be expected to occur even in a "controlled" setting using experienced observers, standard examination techniques and asymptomatic healthy subjects. These findings appear to undermine the expectation that the clinician can reliably apply surface inclinometry to estimate loss of spinal mobility for purposes of impairment determination.
引用
收藏
页码:219 / 224
页数:6
相关论文
共 50 条
  • [31] ESTIMATION OF CREATININE BY JAFFE REACTION - A COMPARISON OF 3 METHODS
    HUSDAN, H
    RAPOPORT, A
    CLINICAL CHEMISTRY, 1968, 14 (03) : 222 - &
  • [32] COMPARISON OF 3 METHODS FOR THE ESTIMATION OF UREA KINETICS IN HEMODIALYSIS
    VANHOLDER, R
    VANTRIMPONT, P
    RINGOIR, S
    KIDNEY INTERNATIONAL, 1988, 33 (01) : 239 - 239
  • [33] ESTIMATION OF OESTRIOL IN AMNIOTIC FLUID - A COMPARISON OF 3 METHODS
    KLOPPER, A
    MICHIE, E
    ALEEM, F
    JOURNAL OF OBSTETRICS & GYNAECOLOGY OF THE BRITISH COMMONWEALTH, 1971, 78 (05): : 444 - &
  • [34] Variability in Flexion Extension Radiographs of the Lumbar Spine: A Comparison of Uncontrolled and Controlled Bending
    Cheng, Boyle
    Castellvi, Anthony E.
    Davis, Reginald J.
    Lee, David C.
    Lorio, Morgan P.
    Prostko, Richard E.
    Wade, Chip
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10
  • [35] Comparison of Tests for Lumbar Flexion and Hip Function in Patients With and Without Axial Spondyloarthritis
    Stolwijk, Carmen
    Ramiro, Sofia
    Vosse, Debby
    Landewe, Robert
    van der Heijde, Desiree
    van Tubergen, Astrid
    ARTHRITIS CARE & RESEARCH, 2015, 67 (04) : 538 - 545
  • [36] A comparison of normal estimation schemes
    Moller, T
    Machiraju, R
    Mueller, K
    Yagel, R
    VISUALIZATION '97 - PROCEEDINGS, 1997, : 19 - +
  • [37] Quantifying surface normal estimation
    Reid, Robert B.
    Oxley, Mark E.
    Eismann, Michael T.
    Goda, Matthew E.
    POLARIZATION: MEASUREMENT, ANALYSIS, AND REMOTE SENSING VII, 2006, 6240
  • [38] EVALUATION OF METHODS FOR THE QUANTIFICATION OF THE FLEXION-RELAXATION PHENOMENON IN THE LUMBAR ERECTOR SPINAE MUSCLES
    Schinkel-Ivy, Alison
    Nairn, Brian C.
    Drake, Janessa D. M.
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2013, 36 (06) : 349 - 358
  • [39] LYSIMETER STUDY OF EVAPOTRANSPIRATION OF CATTAILS AND COMPARISON OF 3 ESTIMATION METHODS
    ABTEW, W
    OBEYSEKERA, J
    TRANSACTIONS OF THE ASAE, 1995, 38 (01): : 121 - 129
  • [40] ESTIMATION OF THE SPECIFIC ACTIVITY OF RADIOIODINATED GONADOTROPINS - COMPARISON OF 3 METHODS
    ENGLEBIENNE, P
    SLEGERS, G
    JOURNAL OF IMMUNOLOGICAL METHODS, 1983, 56 (01) : 135 - 140